RP1HL4Y1T
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
1.5 Pre-shaped 90°L-plate | ![]() ![]() ![]() ![]() | RP1HL4Y1T1L | 0.6mm, 16mm, Left (1㎜ advance) |
RP1HL4Y1T2L | 0.6mm, 16mm, Left (2㎜ advance) | ||
RP1HL4Y1T3L | 0.6mm, 16mm, Left (3㎜ advance) | ||
RP1HL4Y1T4L | 0.6mm, 16mm, Left (4㎜ advance) | ||
RP1HL4Y1T5L | 0.6mm, 16mm, Left (5㎜ advance) | ||
RP1HL4Y1T1R | 0.6mm, 16mm, Right (1㎜ advance) | ||
RP1HL4Y1T2R | 0.6mm, 16mm, Right (2㎜ advance) | ||
RP1HL4Y1T3R | 0.6mm, 16mm, Right (3㎜ advance) | ||
RP1HL4Y1T4R | 0.6mm, 16mm, Right (4㎜ advance) | ||
RP1HL4Y1T5R | 0.6mm, 16mm, Right (5㎜ advance) |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Pre-shaped 90°L-plate Product Catalog.
2. Choose Your Interested 1.5 Pre-shaped 90°L-plate Product.
3. Ask For A Sample To Test 1.5 Pre-shaped 90°L-plate.
4.Make An Order Of XC Medico's 1.5 Pre-shaped 90°L-plate.
5.Become A Dealer Of XC Medico's 1.5 Pre-shaped 90°L-plate.
1.Better Purchase Prices Of 1.5 Pre-shaped 90°L-plate.
2.100% The Highest Quality 1.5 Pre-shaped 90°L-plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Pre-shaped 90°L-plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Pre-shaped 90°L-plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 1.5 Pre-shaped 90° L-plate is an advanced orthopedic implant designed for precise fixation of small bone fractures, particularly in anatomical regions requiring angular stability and minimal hardware prominence. With its pre-contoured design, the plate offers exceptional compatibility with bone geometry, enabling superior fixation and ease of use. This article provides a comprehensive overview of the 1.5 Pre-shaped 90° L-plate, including its features, advantages, clinical applications, risks, and future market prospects.
The 1.5 Pre-shaped 90° L-plate is a specialized implant with an L-shaped design, pre-contoured to fit complex anatomical structures. This implant is primarily used for small bone fractures in areas such as the hand, wrist, and craniofacial regions, where angular support and precise fixation are crucial.
Made from biocompatible materials like titanium or surgical-grade stainless steel, the 1.5 Pre-shaped 90° L-plate combines strength, corrosion resistance, and minimal weight. The 90° angle of the plate ensures optimal stabilization for perpendicular bone fragments, making it a preferred choice for fractures with complex geometries.
The plate is pre-shaped at a precise 90° angle, eliminating the need for intraoperative contouring and saving surgical time.
The thin and lightweight design minimizes hardware prominence, reducing the risk of irritation to surrounding soft tissues.
Optimally spaced holes allow for secure fixation, ensuring stability and proper alignment of bone fragments.
Constructed from titanium or stainless steel, the plate ensures compatibility with human tissue and offers durability against mechanical stress.
Rounded and polished edges prevent soft tissue damage, enhancing patient comfort and reducing postoperative complications.
High-quality materials resist corrosion even in long-term implantation, ensuring reliability and safety.
Titanium versions allow for clear postoperative imaging, facilitating accurate monitoring of fracture healing.
The pre-shaped design eliminates the need for additional contouring, simplifying surgical procedures and reducing operative time.
The 90° L-shape provides angular stability for fractures involving perpendicular or multi-planar fragments.
The low-profile structure ensures minimal hardware visibility, particularly important for craniofacial and hand surgeries.
Smooth edges and a slim profile minimize irritation and risk of soft tissue injury, promoting faster recovery.
Suitable for a wide range of small bone fractures and anatomical regions, making it a highly adaptable implant.
The plate's robust construction ensures long-term fixation and stability, even under biomechanical loads.
Radiolucent properties in titanium plates enable better visualization during follow-up imaging, ensuring optimal monitoring of healing progress.
Provides stable fixation for fractures in the fingers and hand, ensuring proper alignment and restoring function.
Used in small fracture fragments of the wrist, offering reliable stabilization and reducing the risk of malunion.
Ideal for orbital, nasal, and other facial bone fractures where angular stability and precision are essential.
The 90° design ensures optimal stabilization for fractures involving perpendicular or multi-planar bone fragments.
Biocompatible and minimally invasive, the plate is safe for use in pediatric patients, preserving growth plates and reducing complications.
Stabilizes complex fracture patterns with multiple bone fragments, ensuring proper alignment during the healing process.
Improper sterilization or postoperative care can lead to infections at the surgical site.
Overloading or improper fixation may cause screw loosening or plate breakage, necessitating revision surgery.
Poor placement of the plate may result in malunion or delayed healing, affecting overall function.
Incorrect positioning or contouring can lead to irritation or damage to adjacent soft tissues.
Though rare, some patients may exhibit hypersensitivity to the materials used in the implant.
Loose or improperly positioned screws can compromise fixation and require corrective intervention.
Rising road accidents, sports injuries, and workplace fractures are fueling demand for precise orthopedic implants.
Innovations in pre-shaped plate designs and material engineering are enhancing surgical outcomes and boosting adoption.
The global rise in elderly populations, prone to fractures and osteoporosis, is creating sustained demand for small bone fixation implants.
Surgeons and patients increasingly prefer less invasive techniques, driving interest in low-profile and pre-contoured plates.
Expanding healthcare infrastructure in developing regions is expected to increase access to high-quality implants and boost market growth.
Growing awareness among patients about aesthetic and functional outcomes is driving interest in advanced implants like the 1.5 Pre-shaped 90° L-plate.
The 1.5 Pre-shaped 90° L-plate is a cornerstone in small bone fracture management, offering precision, stability, and versatility for complex anatomical regions. Its pre-contoured design, biocompatible materials, and advanced features ensure ease of use, enhanced surgical outcomes, and improved patient satisfaction. While certain risks are inherent, proper training and adherence to surgical protocols can mitigate complications. As the demand for innovative and patient-friendly orthopedic solutions continues to rise, the 1.5 Pre-shaped 90° L-plate is poised to remain a key player in advancing fracture management worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
1.5 Pre-shaped 90°L-plate | ![]() ![]() ![]() ![]() | RP1HL4Y1T1L | 0.6mm, 16mm, Left (1㎜ advance) |
RP1HL4Y1T2L | 0.6mm, 16mm, Left (2㎜ advance) | ||
RP1HL4Y1T3L | 0.6mm, 16mm, Left (3㎜ advance) | ||
RP1HL4Y1T4L | 0.6mm, 16mm, Left (4㎜ advance) | ||
RP1HL4Y1T5L | 0.6mm, 16mm, Left (5㎜ advance) | ||
RP1HL4Y1T1R | 0.6mm, 16mm, Right (1㎜ advance) | ||
RP1HL4Y1T2R | 0.6mm, 16mm, Right (2㎜ advance) | ||
RP1HL4Y1T3R | 0.6mm, 16mm, Right (3㎜ advance) | ||
RP1HL4Y1T4R | 0.6mm, 16mm, Right (4㎜ advance) | ||
RP1HL4Y1T5R | 0.6mm, 16mm, Right (5㎜ advance) |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Pre-shaped 90°L-plate Product Catalog.
2. Choose Your Interested 1.5 Pre-shaped 90°L-plate Product.
3. Ask For A Sample To Test 1.5 Pre-shaped 90°L-plate.
4.Make An Order Of XC Medico's 1.5 Pre-shaped 90°L-plate.
5.Become A Dealer Of XC Medico's 1.5 Pre-shaped 90°L-plate.
1.Better Purchase Prices Of 1.5 Pre-shaped 90°L-plate.
2.100% The Highest Quality 1.5 Pre-shaped 90°L-plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Pre-shaped 90°L-plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Pre-shaped 90°L-plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 1.5 Pre-shaped 90° L-plate is an advanced orthopedic implant designed for precise fixation of small bone fractures, particularly in anatomical regions requiring angular stability and minimal hardware prominence. With its pre-contoured design, the plate offers exceptional compatibility with bone geometry, enabling superior fixation and ease of use. This article provides a comprehensive overview of the 1.5 Pre-shaped 90° L-plate, including its features, advantages, clinical applications, risks, and future market prospects.
The 1.5 Pre-shaped 90° L-plate is a specialized implant with an L-shaped design, pre-contoured to fit complex anatomical structures. This implant is primarily used for small bone fractures in areas such as the hand, wrist, and craniofacial regions, where angular support and precise fixation are crucial.
Made from biocompatible materials like titanium or surgical-grade stainless steel, the 1.5 Pre-shaped 90° L-plate combines strength, corrosion resistance, and minimal weight. The 90° angle of the plate ensures optimal stabilization for perpendicular bone fragments, making it a preferred choice for fractures with complex geometries.
The plate is pre-shaped at a precise 90° angle, eliminating the need for intraoperative contouring and saving surgical time.
The thin and lightweight design minimizes hardware prominence, reducing the risk of irritation to surrounding soft tissues.
Optimally spaced holes allow for secure fixation, ensuring stability and proper alignment of bone fragments.
Constructed from titanium or stainless steel, the plate ensures compatibility with human tissue and offers durability against mechanical stress.
Rounded and polished edges prevent soft tissue damage, enhancing patient comfort and reducing postoperative complications.
High-quality materials resist corrosion even in long-term implantation, ensuring reliability and safety.
Titanium versions allow for clear postoperative imaging, facilitating accurate monitoring of fracture healing.
The pre-shaped design eliminates the need for additional contouring, simplifying surgical procedures and reducing operative time.
The 90° L-shape provides angular stability for fractures involving perpendicular or multi-planar fragments.
The low-profile structure ensures minimal hardware visibility, particularly important for craniofacial and hand surgeries.
Smooth edges and a slim profile minimize irritation and risk of soft tissue injury, promoting faster recovery.
Suitable for a wide range of small bone fractures and anatomical regions, making it a highly adaptable implant.
The plate's robust construction ensures long-term fixation and stability, even under biomechanical loads.
Radiolucent properties in titanium plates enable better visualization during follow-up imaging, ensuring optimal monitoring of healing progress.
Provides stable fixation for fractures in the fingers and hand, ensuring proper alignment and restoring function.
Used in small fracture fragments of the wrist, offering reliable stabilization and reducing the risk of malunion.
Ideal for orbital, nasal, and other facial bone fractures where angular stability and precision are essential.
The 90° design ensures optimal stabilization for fractures involving perpendicular or multi-planar bone fragments.
Biocompatible and minimally invasive, the plate is safe for use in pediatric patients, preserving growth plates and reducing complications.
Stabilizes complex fracture patterns with multiple bone fragments, ensuring proper alignment during the healing process.
Improper sterilization or postoperative care can lead to infections at the surgical site.
Overloading or improper fixation may cause screw loosening or plate breakage, necessitating revision surgery.
Poor placement of the plate may result in malunion or delayed healing, affecting overall function.
Incorrect positioning or contouring can lead to irritation or damage to adjacent soft tissues.
Though rare, some patients may exhibit hypersensitivity to the materials used in the implant.
Loose or improperly positioned screws can compromise fixation and require corrective intervention.
Rising road accidents, sports injuries, and workplace fractures are fueling demand for precise orthopedic implants.
Innovations in pre-shaped plate designs and material engineering are enhancing surgical outcomes and boosting adoption.
The global rise in elderly populations, prone to fractures and osteoporosis, is creating sustained demand for small bone fixation implants.
Surgeons and patients increasingly prefer less invasive techniques, driving interest in low-profile and pre-contoured plates.
Expanding healthcare infrastructure in developing regions is expected to increase access to high-quality implants and boost market growth.
Growing awareness among patients about aesthetic and functional outcomes is driving interest in advanced implants like the 1.5 Pre-shaped 90° L-plate.
The 1.5 Pre-shaped 90° L-plate is a cornerstone in small bone fracture management, offering precision, stability, and versatility for complex anatomical regions. Its pre-contoured design, biocompatible materials, and advanced features ensure ease of use, enhanced surgical outcomes, and improved patient satisfaction. While certain risks are inherent, proper training and adherence to surgical protocols can mitigate complications. As the demand for innovative and patient-friendly orthopedic solutions continues to rise, the 1.5 Pre-shaped 90° L-plate is poised to remain a key player in advancing fracture management worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact