Rpfna
Xcmedico
1 pcs (penghantaran 72 jam)
Pembedahan patah femoral proksimal
Aloi titanium atau keluli tahan karat
CE/ISO: 9001/ISO13485.ETC
Penghantaran 15 hari yang dibuat khas (Tidak termasuk masa penghantaran)
FedEx. Dhl.tnt.ems.etc
Ketersediaan: | |
---|---|
Kuantiti: | |
Produk | Gambar | Model tertentu | Spesifikasi | Produk | Gambar | Model tertentu | Spesifikasi |
PFNA (GAMA) Intramedullary Nail | ![]() | RPFNA09180 | Ф9 × 180 | PFNA (GAMA) Intramedullary Nail | ![]() | RPFNA11380R | Ф11 × 380 r |
RPFNA09200 | Ф9 × 200 | RPFNA11400R | Ф11 × 400 r | ||||
RPFNA09220 | Ф9 × 220 | RPFNA11420R | Ф11 × 420 r | ||||
RPFNA09240 | Ф9 × 240 | RPFNA11440R | Ф11 × 440 r | ||||
RPFNA10180 | Ф10 × 180 | RPFNA11320L | Ф11 × 320 l | ||||
RPFNA10200 | Ф10 × 200 | RPFNA11340L | Ф11 × 340 l | ||||
RPFNA10220 | Ф10 × 220 | RPFNA11360L | Ф11 × 360 l | ||||
RPFNA10240 | Ф10 × 240 | RPFNA11380L | Ф11 × 380 l | ||||
RPFNA11180 | Ф11 × 180 | RPFNA11400L | Ф11 × 400 l | ||||
RPFNA11200 | Ф11 × 200 | RPFNA11420L | Ф11 × 420 l | ||||
RPFNA11220 | Ф11 × 220 | RPFNA11440L | Ф11 × 440 l | ||||
RPFNA11240 | Ф11 × 240 | Memadankan Srews | |||||
RPFNA12180 | Ф12 × 180 | Skru Blad | ![]() | RSDPD10D470 | Ф10.4*70 | ||
RPFNA12200 | Ф12 × 200 | RSDPD10D475 | Ф10.4*75 | ||||
RPFNA12220 | Ф12 × 220 | RSDPD10D480 | Ф10.4*80 | ||||
RPFNA12240 | Ф12 × 240 | RSDPD10D485 | Ф10.4*85 | ||||
RPFNA09320R | Ф9 × 320 r | RSDPD10D490 | Ф10.4*90 | ||||
RPFNA09340R | Ф9 × 340 r | RSDPD10D495 | Ф10.4*95 | ||||
RPFNA09360R | Ф9 × 360 r | RSDPD10D4100 | Ф10.4*100 | ||||
RPFNA09380R | Ф9 × 380 r | RSDPD10D4105 | Ф10.4*105 | ||||
RPFNA09400R | Ф9 × 400 r | RSDPD10D4110 | Ф10.4*110 | ||||
RPFNA09420R | Ф9 × 420 r | RSDPD10D4115 | Ф10.4*115 | ||||
RPFNA09440R | Ф9 × 440 r | RSDPD10D4120 | Ф10.4*120 | ||||
RPFNA09320L | Ф9 × 320 l | Skru penguncian 4.7mm | ![]() | RSPFNALD4726 | Ф4.7*26 | ||
RPFNA09340L | Ф9 × 340 l | RSPFNALD4728 | Ф4.7*28 | ||||
RPFNA09360L | Ф9 × 360 l | RSPFNALD4730 | Ф4.7*30 | ||||
RPFNA09380L | Ф9 × 380 l | RSPFNALD4732 | Ф4.7*32 | ||||
RPFNA09400L | Ф9 × 400 l | RSPFNALD4734 | Ф4.7*34 | ||||
RPFNA09420L | Ф9 × 420 l | RSPFNALD4736 | Ф4.7*36 | ||||
RPFNA09440L | Ф9 × 440 l | RSPFNALD4738 | Ф4.7*38 | ||||
RPFNA10320R | Ф10 × 320 r | RSPFNALD4740 | Ф4.7*40 | ||||
RPFNA10340R | Ф10 × 340 r | RSPFNALD4742 | Ф4.7*42 | ||||
RPFNA10360R | Ф10 × 360 r | RSPFNALD4744 | Ф4.7*44 | ||||
RPFNA10380R | Ф10 × 380 r | RSPFNALD4746 | Ф4.7*46 | ||||
RPFNA10400R | Ф10 × 400 r | RSPFNALD4748 | Ф4.7*48 | ||||
RPFNA10420R | Ф10 × 420 r | RSPFNALD4750 | Ф4.7*50 | ||||
RPFNA10440R | Ф10 × 440 r | RSPFNALD4752 | Ф4.7*52 | ||||
RPFNA10320L | Ф10 × 320 l | RSPFNALD4754 | Ф4.7*54 | ||||
RPFNA10340L | Ф10 × 340 l | RSPFNALD4756 | Ф4.7*56 | ||||
RPFNA10360L | Ф10 × 360 l | RSPFNALD4758 | Ф4.7*58 | ||||
RPFNA10380L | Ф10 × 380 l | RSPFNALD4760 | Ф4.7*60 | ||||
RPFNA10400L | Ф10 × 400 L. | RSPFNALD4764 | Ф4.7*64 | ||||
RPFNA10420L | Ф10 × 420 l | RSPFNALD4768 | Ф4.7*68 | ||||
RPFNA10440L | Ф10 × 440 l | RSPFNALD4772 | Ф4.7*72 | ||||
RPFNA11320R | Ф11 × 320 r | RSPFNALD4776 | Ф4.7*76 | ||||
RPFNA11340R | Ф11 × 340 r | RSPFNALD4780 | Ф4.7*80 | ||||
RPFNA11360R | Ф11 × 360 r | RSPFNALD4784 | Ф4.7*84 |
Akhir topi. Untuk kestabilan putaran yang benar. Pilihan interlocking statik atau dinamik (dinamisasi: 5mm). Menampilkan perhentian keselamatan penyisipan. Akhir kuku distal fleksibel meminimumkan kepekatan tekanan. |
Beberapa pilihan penguncian distal statik atau penguncian dinamik boleh dilakukan melalui lengan yang bertujuan dengan standard PFNA, kecil dan XS. PFNA panjang juga membolehkan dinamisasi sekunder. Peningkatan kestabilan yang disebabkan oleh pemadatan tulang di sekitar bilah PFNA telah terbukti secara biomekanik untuk menghalang putaran dan keruntuhan varus. Bahawa bilah PFNA mempunyai rintangan pemotongan yang jauh lebih tinggi berbanding dengan sistem skru yang biasa digunakan. |
PFNA mempunyai sudut medial-lateral sebanyak 6 ° ini membolehkan penyisipan di hujung trochanter yang lebih besar. Kestabilan putaran dan sudut yang dicapai dengan satu pemadatan elemen tunggal tulang cancellous yang memasukkan bilah PFNA kompak tulang 130 ° yang memberikan penambangan tambahan, yang sangat penting dalam tulang osteoporotik. |
Pemprosesan awal CNC Teknologi kawalan berangka komputer digunakan untuk memproses produk ortopedik dengan tepat. Proses ini mempunyai ciri -ciri ketepatan tinggi, kecekapan tinggi, dan kebolehulangan. Ia dengan cepat dapat menghasilkan peranti perubatan yang disesuaikan yang mematuhi struktur anatomi manusia dan menyediakan pesakit dengan rancangan rawatan yang diperibadikan. | Penggilap produk Tujuan produk ortopedik menggilap adalah untuk meningkatkan hubungan antara implan dan tisu manusia, mengurangkan kepekatan tekanan, dan meningkatkan kestabilan jangka panjang implan. | Pemeriksaan Kualiti Ujian sifat mekanikal produk ortopedik direka untuk mensimulasikan keadaan tekanan tulang manusia, menilai kapasiti galas beban dan ketahanan implan dalam tubuh manusia, dan memastikan keselamatan dan kebolehpercayaan mereka. |
Pakej produk Produk ortopedik dibungkus di dalam bilik steril untuk memastikan produk tersebut dikemas dalam persekitaran yang bersih dan steril untuk mencegah pencemaran mikrob dan memastikan keselamatan pembedahan. |
Penyimpanan produk ortopedik memerlukan pengurusan dan kawalan kualiti yang ketat untuk memastikan kebolehkesanan produk dan mencegah tamat tempoh atau penghantaran yang salah. |
Bilik sampel digunakan untuk menyimpan, memaparkan dan mengurus pelbagai sampel produk ortopedik untuk pertukaran teknologi produk dan latihan. |
1. Tanya XC Medico Team untuk katalog produk kuku intramedullary PFNA.
2. Pilih produk kuku intramedullary PFNA anda.
3. Minta sampel untuk menguji kualiti kuku intramedullary PFNA.
4. Buat perintah kuku intramedullary PFNA XC Medico.
5.belak seorang peniaga kuku intramedullary PFNA XC Medico.
1. Harga pembelian yang lebih baik daripada kuku intramedullary PFNA.
2.100% kuku intramedullary PFNA berkualiti tinggi.
3. Kurang usaha pesanan.
4. Kestabilan harga untuk tempoh perjanjian.
5. Inventori kuku intramedullary PFNA yang mencukupi
6. Penilaian cepat dan mudah dari kuku intramedullary PFNA XC Medico.
7. Jenama yang diiktiraf secara global - XC Medico.
8. Masa akses cepat ke pasukan jualan XC Medico.
9. Ujian Kualiti Tambahan oleh XC Medico Team.
10. Jejaki pesanan XC Medico anda dari awal hingga akhir.
PFNA (antirotasi kuku femoral proksimal), kuku intramedullary anti-putaran femoral proksimal. Sesuai untuk pelbagai jenis patah intertrochanteric; fraktur subtrochanteric; fraktur asas leher femoral; Fraktur leher femoral yang digabungkan dengan fraktur aci femoral; dan fraktur intertrochanteric yang digabungkan dengan fraktur aci femoral.
Kuku utama adalah kosong.
Kuku utama mempunyai sudut penculikan 6 °.
Kuku utama mempunyai reka bentuk tip dan alur yang selagi mungkin.
Hanya satu kuku mengunci yang perlu diletakkan di hujung distal.
Reka bentuk bilah lingkaran mempunyai keupayaan anti-putaran dan anti-pemotongan yang kuat dan kestabilan yang tinggi.
Pembedahan mempunyai trauma kecil, kurang pendarahan, dan pemulihan cepat.
Skru mengunci dan peranti anti-putaran menyediakan penetapan tegas dan mempromosikan penyembuhan patah.
Pesakit boleh menanggung berat badan lebih awal selepas pembedahan, yang kondusif untuk pemulihan fungsi.
PFNA mempunyai kadar komplikasi yang lebih rendah daripada pembedahan tradisional.
Sesuai untuk pesakit tua dengan osteoporosis.
Pembedahan PFNA adalah jenis pembedahan sistem penetapan dalaman femoral proksimal, terutamanya yang sesuai untuk fraktur intertrochanteric pada orang tua. Sebelum operasi, anestesia perlu dilakukan, biasanya digabungkan anestesia tulang belakang atau anestesia umum. Ambil kedudukan sampingan yang sihat, biarkan kuman anggota yang terjejas, dan letakkan tuala steril.
Ambil anestesia intraspinal.
Ambil kedudukan sampingan yang sihat (bahagian yang terjejas berada di atas); Basuh kawasan pembedahan dengan tincture iodin dan alkohol, dan letakkan lembaran steril.
Melakukan pengurangan patah dan mengekalkan pengurangan di bawah fluoroskopi.
Buat insisi dengan ujung trochanter yang lebih besar dari femur sebagai pusat, kira -kira 8 cm panjang, memotong kulit, tisu subkutan, dan fascia yang mendalam, menyentuh puncak trochanter yang lebih besar dari femur, menggunakan pembuka segi tiga di tepi luar rongga medullary.
Gunakan fluoroskopi untuk mengesahkan bahawa jarum panduan memasuki rongga medullary distal.
Selepas kedudukan jarum panduan dan pengurangan patah adalah memuaskan, pilih kuku pFNA dengan panjang yang memuaskan (umumnya 20-24 cm) dan diameter, masukkan kuku intramedullari di sepanjang jarum panduan, dan kedalaman sisipan jarum adalah memuaskan di bawah fluoroskopi.
Pasang bingkai panduan PFNA, memandu kuku mengunci pisau spiral ke leher femoral dan kepala femoral, dan kunci kuku mengunci yang lain.
Jangkitan luka pasca operasi, jangkitan yang mendalam, dll.
perlahan atau nonunion penyembuhan patah.
Kuku intramedullary atau pemecahan skru mengunci.
Kecederaan neurovaskular intraoperatif atau pasca operasi.
Trombosis urat dalam postoperative dari anggota badan yang lebih rendah.
Kalsifikasi pasca operasi tisu lembut di sekitar sendi pinggul.
Pastikan luka bersih dan kering, dan tukar pakaian dengan kerap.
Lakukan latihan berfungsi seperti yang ditetapkan oleh doktor untuk mempromosikan pemulihan mobiliti bersama.
Secara beransur-ansur meningkatkan berat badan mengikut nasihat doktor.
Secara kerap mengkaji X-ray untuk melihat penyembuhan patah tulang.
Fraktur intertrochanteric adalah fraktur biasa dalam ortopedik. Mereka kebanyakannya dilihat pada orang tua. Oleh kerana osteoporosis, patah intertrochanteric sering berlaku selepas kejatuhan tidak sengaja pada orang tua. Masa berjalan selepas pembedahan bergantung pada tahap osteoporosis dan kaedah pembedahan. Jika pembedahan menggunakan penetapan dalaman PFNA, pesakit biasanya boleh menanggung berat badan dengan tongkat selepas satu minggu. Anda boleh berjalan di tanah tanpa tongkat selama dua bulan. Sekiranya terdapat osteoporosis yang teruk, masa yang sepadan harus dilanjutkan sesuai.
Sekiranya kaedah pembedahan adalah penetapan dalaman kuku kosong, masa untuk keluar dari katil harus dilanjutkan. Sesetengah kuku berongga tidak stabil seperti PFNA. Ia biasanya disyorkan bahawa pesakit tinggal di tempat tidur selama kira-kira sebulan, dan kemudian menggunakan tongkat untuk aktiviti berat badan. Biasanya, anda boleh berhenti berjalan selepas 2 hingga 3 bulan. Jika penetapan dalaman pinggul dinamik digunakan, anda boleh keluar dari katil dan menanggung berat badan dengan tongkat selama sebulan, dan anda boleh melepaskan tongkat selepas 2 hingga 3 bulan.
Menurut penyelidikan APOL, jualan pasaran kuku intramedullary global pada tahun 2023 akan kira-kira AS $ 470 juta, dan dijangka berkembang pada CAGR (kadar pertumbuhan tahunan kompaun) lebih daripada 3.82% semasa tempoh ramalan 2024-2030. Ini menunjukkan bahawa pasaran kuku intramedullari, termasuk kuku intramedullary PFNA, akan terus berkembang di seluruh dunia, menyediakan ruang pasaran yang luas untuk pengeluar dan pembekal.
PFNA adalah kaedah yang selamat, berkesan dan minimal invasif untuk merawat fraktur femoral proksimal. Walau bagaimanapun, kejayaan operasi berkait rapat dengan kemahiran doktor, perbezaan individu dari pesakit dan penjagaan pasca operasi. Pesakit harus memilih hospital biasa, menjalani operasi yang dilakukan oleh doktor yang berpengalaman, dan dengan tegas mengikuti arahan doktor untuk pemulihan pasca operasi.
Peringatan Hangat: Artikel ini hanya untuk rujukan dan tidak dapat menggantikan nasihat profesional doktor. Sekiranya anda mempunyai sebarang pertanyaan, sila rujuk doktor anda.
Produk | Gambar | Model tertentu | Spesifikasi | Produk | Gambar | Model tertentu | Spesifikasi |
PFNA (GAMA) Intramedullary Nail | ![]() | RPFNA09180 | Ф9 × 180 | PFNA (GAMA) Intramedullary Nail | ![]() | RPFNA11380R | Ф11 × 380 r |
RPFNA09200 | Ф9 × 200 | RPFNA11400R | Ф11 × 400 r | ||||
RPFNA09220 | Ф9 × 220 | RPFNA11420R | Ф11 × 420 r | ||||
RPFNA09240 | Ф9 × 240 | RPFNA11440R | Ф11 × 440 r | ||||
RPFNA10180 | Ф10 × 180 | RPFNA11320L | Ф11 × 320 l | ||||
RPFNA10200 | Ф10 × 200 | RPFNA11340L | Ф11 × 340 l | ||||
RPFNA10220 | Ф10 × 220 | RPFNA11360L | Ф11 × 360 l | ||||
RPFNA10240 | Ф10 × 240 | RPFNA11380L | Ф11 × 380 l | ||||
RPFNA11180 | Ф11 × 180 | RPFNA11400L | Ф11 × 400 l | ||||
RPFNA11200 | Ф11 × 200 | RPFNA11420L | Ф11 × 420 l | ||||
RPFNA11220 | Ф11 × 220 | RPFNA11440L | Ф11 × 440 l | ||||
RPFNA11240 | Ф11 × 240 | Memadankan Srews | |||||
RPFNA12180 | Ф12 × 180 | Skru Blad | ![]() | RSDPD10D470 | Ф10.4*70 | ||
RPFNA12200 | Ф12 × 200 | RSDPD10D475 | Ф10.4*75 | ||||
RPFNA12220 | Ф12 × 220 | RSDPD10D480 | Ф10.4*80 | ||||
RPFNA12240 | Ф12 × 240 | RSDPD10D485 | Ф10.4*85 | ||||
RPFNA09320R | Ф9 × 320 r | RSDPD10D490 | Ф10.4*90 | ||||
RPFNA09340R | Ф9 × 340 r | RSDPD10D495 | Ф10.4*95 | ||||
RPFNA09360R | Ф9 × 360 r | RSDPD10D4100 | Ф10.4*100 | ||||
RPFNA09380R | Ф9 × 380 r | RSDPD10D4105 | Ф10.4*105 | ||||
RPFNA09400R | Ф9 × 400 r | RSDPD10D4110 | Ф10.4*110 | ||||
RPFNA09420R | Ф9 × 420 r | RSDPD10D4115 | Ф10.4*115 | ||||
RPFNA09440R | Ф9 × 440 r | RSDPD10D4120 | Ф10.4*120 | ||||
RPFNA09320L | Ф9 × 320 l | Skru penguncian 4.7mm | ![]() | RSPFNALD4726 | Ф4.7*26 | ||
RPFNA09340L | Ф9 × 340 l | RSPFNALD4728 | Ф4.7*28 | ||||
RPFNA09360L | Ф9 × 360 l | RSPFNALD4730 | Ф4.7*30 | ||||
RPFNA09380L | Ф9 × 380 l | RSPFNALD4732 | Ф4.7*32 | ||||
RPFNA09400L | Ф9 × 400 l | RSPFNALD4734 | Ф4.7*34 | ||||
RPFNA09420L | Ф9 × 420 l | RSPFNALD4736 | Ф4.7*36 | ||||
RPFNA09440L | Ф9 × 440 l | RSPFNALD4738 | Ф4.7*38 | ||||
RPFNA10320R | Ф10 × 320 r | RSPFNALD4740 | Ф4.7*40 | ||||
RPFNA10340R | Ф10 × 340 r | RSPFNALD4742 | Ф4.7*42 | ||||
RPFNA10360R | Ф10 × 360 r | RSPFNALD4744 | Ф4.7*44 | ||||
RPFNA10380R | Ф10 × 380 r | RSPFNALD4746 | Ф4.7*46 | ||||
RPFNA10400R | Ф10 × 400 r | RSPFNALD4748 | Ф4.7*48 | ||||
RPFNA10420R | Ф10 × 420 r | RSPFNALD4750 | Ф4.7*50 | ||||
RPFNA10440R | Ф10 × 440 r | RSPFNALD4752 | Ф4.7*52 | ||||
RPFNA10320L | Ф10 × 320 l | RSPFNALD4754 | Ф4.7*54 | ||||
RPFNA10340L | Ф10 × 340 l | RSPFNALD4756 | Ф4.7*56 | ||||
RPFNA10360L | Ф10 × 360 l | RSPFNALD4758 | Ф4.7*58 | ||||
RPFNA10380L | Ф10 × 380 l | RSPFNALD4760 | Ф4.7*60 | ||||
RPFNA10400L | Ф10 × 400 L. | RSPFNALD4764 | Ф4.7*64 | ||||
RPFNA10420L | Ф10 × 420 l | RSPFNALD4768 | Ф4.7*68 | ||||
RPFNA10440L | Ф10 × 440 l | RSPFNALD4772 | Ф4.7*72 | ||||
RPFNA11320R | Ф11 × 320 r | RSPFNALD4776 | Ф4.7*76 | ||||
RPFNA11340R | Ф11 × 340 r | RSPFNALD4780 | Ф4.7*80 | ||||
RPFNA11360R | Ф11 × 360 r | RSPFNALD4784 | Ф4.7*84 |
Akhir topi. Untuk kestabilan putaran yang benar. Pilihan interlocking statik atau dinamik (dinamisasi: 5mm). Menampilkan perhentian keselamatan penyisipan. Akhir kuku distal fleksibel meminimumkan kepekatan tekanan. |
Beberapa pilihan penguncian distal statik atau penguncian dinamik boleh dilakukan melalui lengan yang bertujuan dengan standard PFNA, kecil dan XS. PFNA panjang juga membolehkan dinamisasi sekunder. Peningkatan kestabilan yang disebabkan oleh pemadatan tulang di sekitar bilah PFNA telah terbukti secara biomekanik untuk menghalang putaran dan keruntuhan varus. Bahawa bilah PFNA mempunyai rintangan pemotongan yang jauh lebih tinggi berbanding dengan sistem skru yang biasa digunakan. |
PFNA mempunyai sudut medial-lateral sebanyak 6 ° ini membolehkan penyisipan di hujung trochanter yang lebih besar. Kestabilan putaran dan sudut yang dicapai dengan satu pemadatan elemen tunggal tulang cancellous yang memasukkan bilah PFNA kompak tulang 130 ° yang memberikan penambangan tambahan, yang sangat penting dalam tulang osteoporotik. |
Pemprosesan awal CNC Teknologi kawalan berangka komputer digunakan untuk memproses produk ortopedik dengan tepat. Proses ini mempunyai ciri -ciri ketepatan tinggi, kecekapan tinggi, dan kebolehulangan. Ia dengan cepat dapat menghasilkan peranti perubatan yang disesuaikan yang mematuhi struktur anatomi manusia dan menyediakan pesakit dengan rancangan rawatan yang diperibadikan. | Penggilap produk Tujuan produk ortopedik menggilap adalah untuk meningkatkan hubungan antara implan dan tisu manusia, mengurangkan kepekatan tekanan, dan meningkatkan kestabilan jangka panjang implan. | Pemeriksaan Kualiti Ujian sifat mekanikal produk ortopedik direka untuk mensimulasikan keadaan tekanan tulang manusia, menilai kapasiti galas beban dan ketahanan implan dalam tubuh manusia, dan memastikan keselamatan dan kebolehpercayaan mereka. |
Pakej produk Produk ortopedik dibungkus di dalam bilik steril untuk memastikan produk tersebut dikemas dalam persekitaran yang bersih dan steril untuk mencegah pencemaran mikrob dan memastikan keselamatan pembedahan. |
Penyimpanan produk ortopedik memerlukan pengurusan dan kawalan kualiti yang ketat untuk memastikan kebolehkesanan produk dan mencegah tamat tempoh atau penghantaran yang salah. |
Bilik sampel digunakan untuk menyimpan, memaparkan dan mengurus pelbagai sampel produk ortopedik untuk pertukaran teknologi produk dan latihan. |
1. Tanya XC Medico Team untuk katalog produk kuku intramedullary PFNA.
2. Pilih produk kuku intramedullary PFNA anda.
3. Minta sampel untuk menguji kualiti kuku intramedullary PFNA.
4. Buat perintah kuku intramedullary PFNA XC Medico.
5.belak seorang peniaga kuku intramedullary PFNA XC Medico.
1. Harga pembelian yang lebih baik daripada kuku intramedullary PFNA.
2.100% kuku intramedullary PFNA berkualiti tinggi.
3. Kurang usaha pesanan.
4. Kestabilan harga untuk tempoh perjanjian.
5. Inventori kuku intramedullary PFNA yang mencukupi
6. Penilaian cepat dan mudah dari kuku intramedullary PFNA XC Medico.
7. Jenama yang diiktiraf secara global - XC Medico.
8. Masa akses cepat ke pasukan jualan XC Medico.
9. Ujian Kualiti Tambahan oleh XC Medico Team.
10. Jejaki pesanan XC Medico anda dari awal hingga akhir.
PFNA (antirotasi kuku femoral proksimal), kuku intramedullary anti-putaran femoral proksimal. Sesuai untuk pelbagai jenis patah intertrochanteric; fraktur subtrochanteric; fraktur asas leher femoral; Fraktur leher femoral yang digabungkan dengan fraktur aci femoral; dan fraktur intertrochanteric yang digabungkan dengan fraktur aci femoral.
Kuku utama adalah kosong.
Kuku utama mempunyai sudut penculikan 6 °.
Kuku utama mempunyai reka bentuk tip dan alur yang selagi mungkin.
Hanya satu kuku mengunci yang perlu diletakkan di hujung distal.
Reka bentuk bilah lingkaran mempunyai keupayaan anti-putaran dan anti-pemotongan yang kuat dan kestabilan yang tinggi.
Pembedahan mempunyai trauma kecil, kurang pendarahan, dan pemulihan cepat.
Skru mengunci dan peranti anti-putaran menyediakan penetapan tegas dan mempromosikan penyembuhan patah.
Pesakit boleh menanggung berat badan lebih awal selepas pembedahan, yang kondusif untuk pemulihan fungsi.
PFNA mempunyai kadar komplikasi yang lebih rendah daripada pembedahan tradisional.
Sesuai untuk pesakit tua dengan osteoporosis.
Pembedahan PFNA adalah jenis pembedahan sistem penetapan dalaman femoral proksimal, terutamanya yang sesuai untuk fraktur intertrochanteric pada orang tua. Sebelum operasi, anestesia perlu dilakukan, biasanya digabungkan anestesia tulang belakang atau anestesia umum. Ambil kedudukan sampingan yang sihat, biarkan kuman anggota yang terjejas, dan letakkan tuala steril.
Ambil anestesia intraspinal.
Ambil kedudukan sampingan yang sihat (bahagian yang terjejas berada di atas); Basuh kawasan pembedahan dengan tincture iodin dan alkohol, dan letakkan lembaran steril.
Melakukan pengurangan patah dan mengekalkan pengurangan di bawah fluoroskopi.
Buat insisi dengan ujung trochanter yang lebih besar dari femur sebagai pusat, kira -kira 8 cm panjang, memotong kulit, tisu subkutan, dan fascia yang mendalam, menyentuh puncak trochanter yang lebih besar dari femur, menggunakan pembuka segi tiga di tepi luar rongga medullary.
Gunakan fluoroskopi untuk mengesahkan bahawa jarum panduan memasuki rongga medullary distal.
Selepas kedudukan jarum panduan dan pengurangan patah adalah memuaskan, pilih kuku pFNA dengan panjang yang memuaskan (umumnya 20-24 cm) dan diameter, masukkan kuku intramedullari di sepanjang jarum panduan, dan kedalaman sisipan jarum adalah memuaskan di bawah fluoroskopi.
Pasang bingkai panduan PFNA, memandu kuku mengunci pisau spiral ke leher femoral dan kepala femoral, dan kunci kuku mengunci yang lain.
Jangkitan luka pasca operasi, jangkitan yang mendalam, dll.
perlahan atau nonunion penyembuhan patah.
Kuku intramedullary atau pemecahan skru mengunci.
Kecederaan neurovaskular intraoperatif atau pasca operasi.
Trombosis urat dalam postoperative dari anggota badan yang lebih rendah.
Kalsifikasi pasca operasi tisu lembut di sekitar sendi pinggul.
Pastikan luka bersih dan kering, dan tukar pakaian dengan kerap.
Lakukan latihan berfungsi seperti yang ditetapkan oleh doktor untuk mempromosikan pemulihan mobiliti bersama.
Secara beransur-ansur meningkatkan berat badan mengikut nasihat doktor.
Secara kerap mengkaji X-ray untuk memerhatikan penyembuhan patah tulang.
Fraktur intertrochanteric adalah fraktur biasa dalam ortopedik. Mereka kebanyakannya dilihat pada orang tua. Oleh kerana osteoporosis, patah intertrochanteric sering berlaku selepas kejatuhan tidak sengaja pada orang tua. Masa berjalan selepas pembedahan bergantung pada tahap osteoporosis dan kaedah pembedahan. Jika pembedahan menggunakan penetapan dalaman PFNA, pesakit biasanya boleh menanggung berat badan dengan tongkat selepas satu minggu. Anda boleh berjalan di tanah tanpa tongkat selama dua bulan. Sekiranya terdapat osteoporosis yang teruk, masa yang sepadan harus dilanjutkan sesuai.
Sekiranya kaedah pembedahan adalah penetapan dalaman kuku kosong, masa untuk keluar dari katil harus dilanjutkan. Sesetengah kuku berongga tidak stabil seperti PFNA. Ia biasanya disyorkan bahawa pesakit tinggal di tempat tidur selama kira-kira sebulan, dan kemudian menggunakan tongkat untuk aktiviti berat badan. Biasanya, anda boleh berhenti berjalan selepas 2 hingga 3 bulan. Jika penetapan dalaman pinggul dinamik digunakan, anda boleh keluar dari katil dan menanggung berat badan dengan tongkat selama sebulan, dan anda boleh melepaskan tongkat selepas 2 hingga 3 bulan.
Menurut penyelidikan APOL, jualan pasaran kuku intramedullary global pada tahun 2023 akan kira-kira AS $ 470 juta, dan dijangka berkembang pada CAGR (kadar pertumbuhan tahunan kompaun) lebih daripada 3.82% semasa tempoh ramalan 2024-2030. Ini menunjukkan bahawa pasaran kuku intramedullari, termasuk kuku intramedullary PFNA, akan terus berkembang di seluruh dunia, menyediakan ruang pasaran yang luas untuk pengeluar dan pembekal.
PFNA adalah kaedah yang selamat, berkesan dan minimal invasif untuk merawat fraktur femoral proksimal. Walau bagaimanapun, kejayaan operasi berkait rapat dengan kemahiran doktor, perbezaan individu dari pesakit dan penjagaan pasca operasi. Pesakit harus memilih hospital biasa, menjalani operasi yang dilakukan oleh doktor yang berpengalaman, dan dengan tegas mengikuti arahan doktor untuk pemulihan pasca operasi.
Peringatan Hangat: Artikel ini hanya untuk rujukan dan tidak dapat menggantikan nasihat profesional doktor. Sekiranya anda mempunyai sebarang pertanyaan, sila rujuk doktor anda.
Hubungi