Rpfna
Xcmedico
1 računalniki (72 ur dostava)
Proksimalna operacija zloma stegnenice
Titanova zlitina ali nerjavno jeklo
CE/ISO: 9001/ISO13485.ETC
15-dnevna dostava po meri (brez časa pošiljanja)
Fedex. Dhl.tnt.ems.etc
Razpoložljivost: | |
---|---|
Količina: | |
Izdelki | Slika | Določeni modeli | Specifikacija | Izdelki | Slika | Določeni modeli | Specifikacija |
Pfna (Gama) Intramedullarni žebelj | ![]() | RPFNA09180 | L9 × 180 | Pfna (Gama) Intramedullarni žebelj | ![]() | RPFNA11380R | L11 × 380 r |
RPFNA09200 | L9 × 200 | RPFNA11400R | L11 × 400 r | ||||
RPFNA09220 | F9 × 220 | RPFNA11420R | L11 × 420 r | ||||
RPFNA09240 | F9 × 240 | RPFNA11440R | L11 × 440 r | ||||
RPFNA10180 | L10 × 180 | RPFNA11320L | L11 × 320 l | ||||
RPFNA10200 | Ф10 × 200 | RPFNA11340L | L11 × 340 l | ||||
RPFNA10220 | Ф10 × 220 | RPFNA11360L | L11 × 360 l | ||||
RPFNA10240 | L10 × 240 | RPFNA11380L | L11 × 380 l | ||||
RPFNA11180 | L11 × 180 | RPFNA11400L | L11 × 400 l | ||||
RPFNA11200 | L11 × 200 | RPFNA11420L | L11 × 420 l | ||||
RPFNA11220 | L11 × 220 | RPFNA11440L | L11 × 440 l | ||||
RPFNA11240 | L11 × 240 | Ujemanje Srews | |||||
RPFNA12180 | L12 × 180 | Blad vijak | ![]() | RSDPD10D470 | L 10.4*70 | ||
RPFNA12200 | F12 × 200 | RSDPD10D475 | Ф10.4*75 | ||||
RPFNA12220 | F12 × 220 | RSDPD10D480 | Ф10.4*80 | ||||
RPFNA12240 | F12 × 240 | RSDPD10D485 | Ф10.4*85 | ||||
RPFNA09320R | L9 × 320 r | RSDPD10D490 | Ф10.4*90 | ||||
RPFNA09340R | L9 × 340 r | RSDPD10D495 | Ф10.4*95 | ||||
RPFNA09360R | L9 × 360 r | RSDPD10D4100 | Ф10.4*100 | ||||
RPFNA09380R | L9 × 380 r | RSDPD10D4105 | Ф10.4*105 | ||||
RPFNA09400R | L9 × 400 r | RSDPD10D4110 | Ф10.4*110 | ||||
RPFNA09420R | L9 × 420 r | RSDPD10D4115 | Ф10.4*115 | ||||
RPFNA09440R | L9 × 440 r | RSDPD10D4120 | Ф10.4*120 | ||||
RPFNA09320L | L9 × 320 l | 4,7 mm zaklepni vijak | ![]() | Rspfnald4726 | F4.7*26 | ||
RPFNA09340L | L9 × 340 l | Rspfnald4728 | F4.7*28 | ||||
RPFNA09360L | L9 × 360 l | Rspfnald4730 | F4.7*30 | ||||
RPFNA09380L | L9 × 380 l | Rspfnald4732 | F4.7*32 | ||||
RPFNA09400L | L9 × 400 l | Rspfnald4734 | F4.7*34 | ||||
RPFNA09420L | L9 × 420 l | Rspfnald4736 | F4.7*36 | ||||
RPFNA09440L | L9 × 440 l | Rspfnald4738 | F4.7*38 | ||||
RPFNA10320R | Ф10 × 320 r | Rspfnald4740 | F4.7*40 | ||||
RPFNA10340R | Ф10 × 340 r | Rspfnald4742 | F4.7*42 | ||||
RPFNA10360R | L10 × 360 r | Rspfnald4744 | F4.7*44 | ||||
RPFNA10380R | Ф10 × 380 r | Rspfnald4746 | F4.7*46 | ||||
RPFNA10400R | Ф10 × 400 r | Rspfnald4748 | F4.7*48 | ||||
RPFNA10420R | L10 × 420 r | Rspfnald4750 | F4.7*50 | ||||
RPFNA10440R | Ф10 × 440 r | Rspfnald4752 | F4.7*52 | ||||
RPFNA10320L | L10 × 320 l | Rspfnald4754 | F4.7*54 | ||||
RPFNA10340L | L10 × 340 l | Rspfnald4756 | F4.7*56 | ||||
RPFNA10360L | L10 × 360 l | Rspfnald4758 | F4.7*58 | ||||
RPFNA10380L | L10 × 380 l | Rspfnald4760 | F4.7*60 | ||||
RPFNA10400L | L10 × 400 l | Rspfnald4764 | F4.7*64 | ||||
RPFNA10420L | L10 × 420 l | Rspfnald4768 | F4.7*68 | ||||
RPFNA10440L | L10 × 440 l | Rspfnald4772 | F4.7*72 | ||||
RPFNA11320R | L11 × 320 r | Rspfnald4776 | F4.7*76 | ||||
RPFNA11340R | L11 × 340 r | Rspfnald4780 | F4.7*80 | ||||
RPFNA11360R | L11 × 360 r | Rspfnald4784 | F4.7*84 |
Končna kapica. Za resnično rotacijsko stabilnost. Izbira statičnega ali dinamičnega prepletanja (dinamizacija: 5 mm). Z varnostnim postankom vstavitve. Prilagodljiv distalni konec nohtov zmanjšuje koncentracijo stresa. |
Več distalnih možnosti zaklepanja statično ali dinamično zaklepanje se lahko izvede prek ciljalne roke s PFNA Standard, Small in XS. PFNA Long dodatno omogoča sekundarno dinamizacijo. Povečana stabilnost, ki jo povzroča stiskanje kosti okoli rezila PFNA, je biomehanično dokazano, da retard vrti in varus propad. Da je imelo rezilo PFNA v primerjavi s pogosto uporabljenimi vijačnimi sistemi bistveno večji upornost. |
PFNA ima medialno-lateralni kot 6 °, kar omogoča vstavitev na konici večjega trohanterja. Rotacijska in kotna stabilnost, dosežena z enim enotnim zbijanjem kosti, ki vstavi rezilo pfna, kompaktno kost 130 °, kar zagotavlja dodatno sidranje, kar je še posebej pomembno v osteoporotični kosti. |
CNC predhodna obdelava Tehnologija računalniškega numeričnega krmiljenja se uporablja za natančno obdelavo ortopedskih izdelkov. Ta postopek ima značilnosti visoke natančnosti, visoke učinkovitosti in ponovljivosti. Hitro lahko ustvari prilagojene medicinske pripomočke, ki ustrezajo človeški anatomski strukturi in bolnikom zagotavljajo prilagojene načrte zdravljenja. | Poliranje izdelkov Namen poliranja ortopedskih izdelkov je izboljšati stik med vsadkom in človeškim tkivom, zmanjšati koncentracijo stresa in izboljšati dolgoročno stabilnost vsadka. | Pregled kakovosti Test mehanskih lastnosti ortopedskih izdelkov je zasnovan tako, da simulira stresne razmere človeških kosti, oceni zmogljivosti in trajnost vsadkov v človeškem telesu in zagotavlja njihovo varnost in zanesljivost. |
Paket izdelkov Ortopedski izdelki so pakirani v sterilni sobi, da se zagotovi, da je izdelek zaprt v čisto, sterilno okolje, da se prepreči mikrobna kontaminacija in zagotovi kirurško varnost. |
Skladiščenje ortopedskih izdelkov zahteva strogo upravljanje in nadzor nad kakovostjo in nadzor kakovosti, da se zagotovi sledljivost izdelkov in prepreči iztekanje ali napačno pošiljko. |
Vzorčna soba se uporablja za shranjevanje, prikazovanje in upravljanje različnih vzorcev ortopedskih izdelkov za izmenjave tehnologije izdelkov in usposabljanje. |
1. Vprašajte XC Medico Ekipa za katalog izdelkov INTRamedUllary INTRAMULLARY.
2. Izberite svoj zainteresiran intramedullarni izdelek za nohte PFNA.
3. Prosite za vzorec za preizkušanje kakovosti nohtov PFNA.
4. Vzemite vrstni red intramedullarni noht XC Medico.
5.Bome trgovec intramedullarni žebelj XC Medico PFNA.
1. Boljše cene nakupnih cenov intramedularjev PFNA.
2,100% najvišje kakovosti intramedullarni nohti PFNA.
3. Manj prizadevanja za naročanje.
4. stabilnost cen za obdobje dogovora.
5. Zadostna inventarna intramedullarna nohta PFNA
6. hitra in enostavna ocena intramedullarijskih nohtov XC Medico.
7. Globalno priznana blagovna znamka - XC Medico.
8. Čas hitrega dostopa do prodajne ekipe XC Medico.
9. Dodatni preizkus kakovosti s strani XC Medicove ekipe.
10. Sledite svojemu naročilo XC Medica od začetka do konca.
PFNA (proksimalna antirotacija nohtov (proksimalna stegnenica), proksimalna intramedalarna nohta proksimalne stegnenice. Primerno za različne vrste intertrohanteričnih zlomov; subtrohanterični zlomi; Zlomi osnovnega vratu stegnenic; Zlomi stegneničnih vratu v kombinaciji z zlomi stegnenice; in intertrohanterične zlome v kombinaciji z zlomi stegnenice.
Glavni žebelj je votlo.
Glavni noht ima 6 ° ugrabitveni kot.
Glavni žebelj ima dizajn konic in žleba, ki je čim dlje.
Na distalnem koncu je treba namestiti samo en zaklepni žebelj.
Zasnova spiralnega rezila ima močne protipotacijske in protikaturne zmogljivosti ter visoko stabilnost.
Operacija ima majhne travme, manj krvavitve in hitro okrevanje.
Zaklepni vijaki in naprave proti vrvitvi zagotavljajo trdno fiksacijo in spodbujajo celjenje zloma.
Bolniki lahko delno nosijo težo zgodaj po operaciji, kar je spodbudno za funkcionalno okrevanje.
PFNA ima nižjo stopnjo zapletov kot tradicionalna operacija.
Primerno za starejše bolnike z osteoporozo.
Kirurgija PFNA je nova vrsta proksimalne operacije notranjega fiksacijskega sistema, še posebej primerna za medtrohanterične zlome pri starejših. Pred operacijo je treba opraviti anestezijo, običajno kombinirano hrbtenično-epiduralno anestezijo ali splošno anestezijo. Vzemite zdrav stranski položaj, razkužite prizadeti okončino in položite sterilno brisačo.
Vzemite intraspinalno anestezijo.
Vzemite zdrav stranski položaj (prizadeta stran je na vrhu); Razkužite kirurško območje z jodno tinkturo in alkoholom ter položite sterilno pločevino.
Izvedite zmanjšanje zloma in ohranite zmanjšanje v fluoroskopiji.
Naredite rez s konico večjega trohanterja stegnenice kot središče, dolge približno 8 cm, prerežite kožo, podkožno tkivo in globoko fascijo, dotaknite se vrha večjega trohanterja stegnenice, pri čemer uporabite trikotni odpiralec na zunanjem robu večjega roba večjega apeja, ki je vstavil, da se vstavite, da razširite kost in vstavite lovsko kost, nato medularna votlina.
Uporabite fluoroskopijo, da potrdite, da vodilna igla vstopi v distalno medularno votlino.
Ko sta položaj vodilne igle in zmanjšanje zloma zadovoljiva, izberite PFNA žebelj z zadovoljivo dolžino (na splošno 20-24 cm) in premerom, vstavite intramedularni žebelj vzdolž vodilne igle, globina vstavitve igle pa je zadovoljiva pod fluoroskopijo.
Namestite vodni okvir PFNA, v stegnenični vrat in stegnenico zaklenite nož za zaklepanje noža in zaklenite druge zaklepne nohte.
Pooperativna okužba z ranami, globoka okužba itd.
Počasi ali nepopustljivi celjenje zloma.
Intramedullarni noht ali lom zaklepnega vijaka.
Intraoperativna ali pooperativna nevrovaskularna poškodba.
Pooperativna tromboza globokih žil spodnjih okončin.
Pooperativna kalcifikacija mehkega tkiva okoli kolčnega sklepa.
Rano naj bo čista in suha ter redno menjajte preliv.
Izvedite funkcionalne vaje, kot jih predpiše zdravnik za spodbujanje okrevanja skupne mobilnosti.
Postopoma povečujete težo v skladu z zdravnikovimi nasveti.
Redno pregledujte rentgenske žarke, da opazujete celjenje zlomov.
Medtrohanterični zlomi so pogosti zlomi v ortopediji. V glavnem jih opazimo pri starejših. Zaradi osteoporoze se med nenamernim padcem pri starejših pogosto pojavijo intertrohanterični zlomi. Čas hoje po operaciji je odvisen od stopnje osteoporoze in kirurške metode. Če operacija uporablja notranjo fiksacijo PFNA, lahko pacient po enem tednu na splošno nosi težo z bergle. Lahko hodiš po tleh brez bergle približno dva meseca. Če obstaja huda osteoporoza, je treba ustrezen čas podaljšati, če je primerno.
Če je kirurška metoda notranja fiksacija votlega nohta, je treba čas za vstajanje iz postelje relativno podaljšati. Nekateri votli nohti niso tako stabilni kot PFNA. Običajno je priporočljivo, da pacienti ostanejo v postelji približno mesec dni in nato uporabljajo ščetke za dejavnosti, ki nosijo težo. Običajno se lahko odpovedate hoji po 2 do 3 mesecih. Če se uporablja notranja fiksacija dinamične kolke, lahko na splošno vstanete iz postelje in nosite težo z bergle približno mesec dni, bergle pa se lahko odpovedujete po 2 do 3 mesecih.
Glede na raziskave APOL bo globalna prodana intramedularna trg nohtov leta 2023 približno 470 milijonov ameriških dolarjev, v predvidenem obdobju 2024–2030 pa naj bi rasla na CAGR (sestavljena letna stopnja rasti) v višini več kot 3,82%. To kaže, da se bo intramedularni trg nohtov, vključno z intramedullarnimi nohti PFNA, še naprej širil po vsem svetu, kar bo zagotavljalo širok tržni prostor za proizvajalce in dobavitelje.
PFNA je varna, učinkovita in minimalno invazivna metoda za zdravljenje proksimalnih zlomov stegnenice. Vendar je uspeh operacije tesno povezan s spretnostmi zdravnika, individualnimi razlikami pacienta in pooperativno oskrbo. Bolniki bi morali izbrati redno bolnišnico, izvajati operacijo izkušenega zdravnika in strogo upoštevati zdravnikova navodila za pooperativno rehabilitacijo.
Topel opomnik: Ta članek je samo za referenco in ne more nadomestiti zdravnikovega strokovnega nasveta. Če imate kakršna koli vprašanja, se posvetujte s svojim zdravnikom.
Izdelki | Slika | Določeni modeli | Specifikacija | Izdelki | Slika | Določeni modeli | Specifikacija |
Pfna (Gama) Intramedullarni žebelj | ![]() | RPFNA09180 | L9 × 180 | Pfna (Gama) Intramedullarni žebelj | ![]() | RPFNA11380R | L11 × 380 r |
RPFNA09200 | L9 × 200 | RPFNA11400R | L11 × 400 r | ||||
RPFNA09220 | F9 × 220 | RPFNA11420R | L11 × 420 r | ||||
RPFNA09240 | F9 × 240 | RPFNA11440R | L11 × 440 r | ||||
RPFNA10180 | L10 × 180 | RPFNA11320L | L11 × 320 l | ||||
RPFNA10200 | Ф10 × 200 | RPFNA11340L | L11 × 340 l | ||||
RPFNA10220 | Ф10 × 220 | RPFNA11360L | L11 × 360 l | ||||
RPFNA10240 | L10 × 240 | RPFNA11380L | L11 × 380 l | ||||
RPFNA11180 | L11 × 180 | RPFNA11400L | L11 × 400 l | ||||
RPFNA11200 | L11 × 200 | RPFNA11420L | L11 × 420 l | ||||
RPFNA11220 | L11 × 220 | RPFNA11440L | L11 × 440 l | ||||
RPFNA11240 | L11 × 240 | Ujemanje Srews | |||||
RPFNA12180 | L12 × 180 | Blad vijak | ![]() | RSDPD10D470 | L 10.4*70 | ||
RPFNA12200 | F12 × 200 | RSDPD10D475 | Ф10.4*75 | ||||
RPFNA12220 | F12 × 220 | RSDPD10D480 | Ф10.4*80 | ||||
RPFNA12240 | F12 × 240 | RSDPD10D485 | Ф10.4*85 | ||||
RPFNA09320R | L9 × 320 r | RSDPD10D490 | Ф10.4*90 | ||||
RPFNA09340R | L9 × 340 r | RSDPD10D495 | Ф10.4*95 | ||||
RPFNA09360R | L9 × 360 r | RSDPD10D4100 | Ф10.4*100 | ||||
RPFNA09380R | L9 × 380 r | RSDPD10D4105 | Ф10.4*105 | ||||
RPFNA09400R | L9 × 400 r | RSDPD10D4110 | Ф10.4*110 | ||||
RPFNA09420R | L9 × 420 r | RSDPD10D4115 | Ф10.4*115 | ||||
RPFNA09440R | L9 × 440 r | RSDPD10D4120 | Ф10.4*120 | ||||
RPFNA09320L | L9 × 320 l | 4,7 mm zaklepni vijak | ![]() | Rspfnald4726 | F4.7*26 | ||
RPFNA09340L | L9 × 340 l | Rspfnald4728 | F4.7*28 | ||||
RPFNA09360L | L9 × 360 l | Rspfnald4730 | F4.7*30 | ||||
RPFNA09380L | L9 × 380 l | Rspfnald4732 | F4.7*32 | ||||
RPFNA09400L | L9 × 400 l | Rspfnald4734 | F4.7*34 | ||||
RPFNA09420L | L9 × 420 l | Rspfnald4736 | F4.7*36 | ||||
RPFNA09440L | L9 × 440 l | Rspfnald4738 | F4.7*38 | ||||
RPFNA10320R | Ф10 × 320 r | Rspfnald4740 | F4.7*40 | ||||
RPFNA10340R | Ф10 × 340 r | Rspfnald4742 | F4.7*42 | ||||
RPFNA10360R | L10 × 360 r | Rspfnald4744 | F4.7*44 | ||||
RPFNA10380R | Ф10 × 380 r | Rspfnald4746 | F4.7*46 | ||||
RPFNA10400R | Ф10 × 400 r | Rspfnald4748 | F4.7*48 | ||||
RPFNA10420R | L10 × 420 r | Rspfnald4750 | F4.7*50 | ||||
RPFNA10440R | Ф10 × 440 r | Rspfnald4752 | F4.7*52 | ||||
RPFNA10320L | L10 × 320 l | Rspfnald4754 | F4.7*54 | ||||
RPFNA10340L | L10 × 340 l | Rspfnald4756 | F4.7*56 | ||||
RPFNA10360L | L10 × 360 l | Rspfnald4758 | F4.7*58 | ||||
RPFNA10380L | L10 × 380 l | Rspfnald4760 | F4.7*60 | ||||
RPFNA10400L | L10 × 400 l | Rspfnald4764 | F4.7*64 | ||||
RPFNA10420L | L10 × 420 l | Rspfnald4768 | F4.7*68 | ||||
RPFNA10440L | L10 × 440 l | Rspfnald4772 | F4.7*72 | ||||
RPFNA11320R | L11 × 320 r | Rspfnald4776 | F4.7*76 | ||||
RPFNA11340R | L11 × 340 r | Rspfnald4780 | F4.7*80 | ||||
RPFNA11360R | L11 × 360 r | Rspfnald4784 | F4.7*84 |
Končna kapica. Za resnično rotacijsko stabilnost. Izbira statičnega ali dinamičnega prepletanja (dinamizacija: 5 mm). Z varnostnim postankom vstavitve. Prilagodljiv distalni konec nohtov zmanjšuje koncentracijo stresa. |
Več distalnih možnosti zaklepanja statično ali dinamično zaklepanje se lahko izvede prek ciljalne roke s PFNA Standard, Small in XS. PFNA Long dodatno omogoča sekundarno dinamizacijo. Povečana stabilnost, ki jo povzroča stiskanje kosti okoli rezila PFNA, je biomehanično dokazano, da retard vrti in varus propad. Da je imelo rezilo PFNA v primerjavi s pogosto uporabljenimi vijačnimi sistemi bistveno večji upornost. |
PFNA ima medialno-lateralni kot 6 °, kar omogoča vstavitev na konici večjega trohanterja. Rotacijska in kotna stabilnost, dosežena z enim enotnim zbijanjem kosti, ki vstavi rezilo pfna, kompaktno kost 130 °, kar zagotavlja dodatno sidranje, kar je še posebej pomembno v osteoporotični kosti. |
CNC predhodna obdelava Tehnologija računalniškega numeričnega krmiljenja se uporablja za natančno obdelavo ortopedskih izdelkov. Ta postopek ima značilnosti visoke natančnosti, visoke učinkovitosti in ponovljivosti. Hitro lahko ustvari prilagojene medicinske pripomočke, ki ustrezajo človeški anatomski strukturi in bolnikom zagotavljajo prilagojene načrte zdravljenja. | Poliranje izdelkov Namen poliranja ortopedskih izdelkov je izboljšati stik med vsadkom in človeškim tkivom, zmanjšati koncentracijo stresa in izboljšati dolgoročno stabilnost vsadka. | Pregled kakovosti Test mehanskih lastnosti ortopedskih izdelkov je zasnovan tako, da simulira stresne razmere človeških kosti, oceni zmogljivosti in trajnost vsadkov v človeškem telesu in zagotavlja njihovo varnost in zanesljivost. |
Paket izdelkov Ortopedski izdelki so pakirani v sterilni sobi, da se zagotovi, da je izdelek zaprt v čisto, sterilno okolje, da se prepreči mikrobna kontaminacija in zagotovi kirurško varnost. |
Skladiščenje ortopedskih izdelkov zahteva strogo upravljanje in nadzor nad kakovostjo in nadzor kakovosti, da se zagotovi sledljivost izdelkov in prepreči iztekanje ali napačno pošiljko. |
Vzorčna soba se uporablja za shranjevanje, prikazovanje in upravljanje različnih vzorcev ortopedskih izdelkov za izmenjave tehnologije izdelkov in usposabljanje. |
1. Vprašajte XC Medico Ekipa za katalog izdelkov INTRamedUllary INTRAMULLARY.
2. Izberite svoj zainteresiran intramedullarni izdelek za nohte PFNA.
3. Prosite za vzorec za preizkušanje kakovosti nohtov PFNA.
4. Vzemite vrstni red intramedullarni noht XC Medico.
5.Bome trgovec intramedullarni žebelj XC Medico PFNA.
1. Boljše cene nakupnih cenov intramedularjev PFNA.
2,100% najvišje kakovosti intramedullarni nohti PFNA.
3. Manj prizadevanja za naročanje.
4. stabilnost cen za obdobje dogovora.
5. Zadostna inventarna intramedullarna nohta PFNA
6. hitra in enostavna ocena intramedullarijskih nohtov XC Medico.
7. Globalno priznana blagovna znamka - XC Medico.
8. Čas hitrega dostopa do prodajne ekipe XC Medico.
9. Dodatni preizkus kakovosti s strani XC Medicove ekipe.
10. Sledite svojemu naročilo XC Medica od začetka do konca.
PFNA (proksimalna antirotacija nohtov (proksimalna stegnenica), proksimalna intramedalarna nohta proksimalne stegnenice. Primerno za različne vrste intertrohanteričnih zlomov; subtrohanterični zlomi; Zlomi osnovnega vratu stegnenic; Zlomi stegneničnih vratu v kombinaciji z zlomi stegnenice; in intertrohanterične zlome v kombinaciji z zlomi stegnenice.
Glavni žebelj je votlo.
Glavni noht ima 6 ° ugrabitveni kot.
Glavni žebelj ima dizajn konic in žleba, ki je čim dlje.
Na distalnem koncu je treba namestiti samo en zaklepni žebelj.
Zasnova spiralnega rezila ima močne protipotacijske in protikaturne zmogljivosti ter visoko stabilnost.
Operacija ima majhne travme, manj krvavitve in hitro okrevanje.
Zaklepni vijaki in naprave proti vrvitvi zagotavljajo trdno fiksacijo in spodbujajo celjenje zloma.
Bolniki lahko delno nosijo težo zgodaj po operaciji, kar je spodbudno za funkcionalno okrevanje.
PFNA ima nižjo stopnjo zapletov kot tradicionalna operacija.
Primerno za starejše bolnike z osteoporozo.
Kirurgija PFNA je nova vrsta proksimalne operacije notranjega fiksacijskega sistema, še posebej primerna za medtrohanterične zlome pri starejših. Pred operacijo je treba opraviti anestezijo, običajno kombinirano hrbtenično-epiduralno anestezijo ali splošno anestezijo. Vzemite zdrav stranski položaj, razkužite prizadeti okončino in položite sterilno brisačo.
Vzemite intraspinalno anestezijo.
Vzemite zdrav stranski položaj (prizadeta stran je na vrhu); Razkužite kirurško območje z jodno tinkturo in alkoholom ter položite sterilno pločevino.
Izvedite zmanjšanje zloma in ohranite zmanjšanje v fluoroskopiji.
Naredite rez s konico večjega trohanterja stegnenice kot središče, dolge približno 8 cm, prerežite kožo, podkožno tkivo in globoko fascijo, dotaknite se vrha večjega trohanterja stegnenice, pri čemer uporabite trikotni odpiralec na zunanjem robu večjega roba večjega apeja, ki je vstavil, da se vstavite, da razširite kost in vstavite lovsko kost, nato medularna votlina.
Uporabite fluoroskopijo, da potrdite, da vodilna igla vstopi v distalno medularno votlino.
Ko sta položaj vodilne igle in zmanjšanje zloma zadovoljiva, izberite PFNA žebelj z zadovoljivo dolžino (na splošno 20-24 cm) in premerom, vstavite intramedularni žebelj vzdolž vodilne igle, globina vstavitve igle pa je zadovoljiva pod fluoroskopijo.
Namestite vodni okvir PFNA, v stegnenični vrat in stegnenico zaklenite nož za zaklepanje noža in zaklenite druge zaklepne nohte.
Pooperativna okužba z ranami, globoka okužba itd.
Počasi ali nepopustljivi celjenje zloma.
Intramedullarni noht ali lom zaklepnega vijaka.
Intraoperativna ali pooperativna nevrovaskularna poškodba.
Pooperativna tromboza globokih žil spodnjih okončin.
Pooperativna kalcifikacija mehkega tkiva okoli kolčnega sklepa.
Rano naj bo čista in suha ter redno menjajte preliv.
Izvedite funkcionalne vaje, kot jih predpiše zdravnik za spodbujanje okrevanja skupne mobilnosti.
Postopoma povečujete težo v skladu z zdravnikovimi nasveti.
Redno pregledujte rentgenske žarke, da opazujete celjenje zlomov.
Medtrohanterični zlomi so pogosti zlomi v ortopediji. V glavnem jih opazimo pri starejših. Zaradi osteoporoze se med nenamernim padcem pri starejših pogosto pojavijo intertrohanterični zlomi. Čas hoje po operaciji je odvisen od stopnje osteoporoze in kirurške metode. Če operacija uporablja notranjo fiksacijo PFNA, lahko pacient po enem tednu na splošno nosi težo z bergle. Lahko hodiš po tleh brez bergle približno dva meseca. Če obstaja huda osteoporoza, je treba ustrezen čas podaljšati, če je primerno.
Če je kirurška metoda notranja fiksacija votlega nohta, je treba čas za vstajanje iz postelje relativno podaljšati. Nekateri votli nohti niso tako stabilni kot PFNA. Običajno je priporočljivo, da pacienti ostanejo v postelji približno mesec dni in nato uporabljajo ščetke za dejavnosti, ki nosijo težo. Običajno se lahko odpovedate hoji po 2 do 3 mesecih. Če se uporablja notranja fiksacija dinamične kolke, lahko na splošno vstanete iz postelje in nosite težo z bergle približno mesec dni, bergle pa se lahko odpovedujete po 2 do 3 mesecih.
Glede na raziskave APOL bo globalna prodana intramedularna trg nohtov leta 2023 približno 470 milijonov ameriških dolarjev, v predvidenem obdobju 2024–2030 pa naj bi rasla na CAGR (sestavljena letna stopnja rasti) v višini več kot 3,82%. To kaže, da se bo intramedularni trg nohtov, vključno z intramedullarnimi nohti PFNA, še naprej širil po vsem svetu, kar bo zagotavljalo širok tržni prostor za proizvajalce in dobavitelje.
PFNA je varna, učinkovita in minimalno invazivna metoda za zdravljenje proksimalnih zlomov stegnenice. Vendar je uspeh operacije tesno povezan s spretnostmi zdravnika, individualnimi razlikami pacienta in pooperativno oskrbo. Bolniki bi morali izbrati redno bolnišnico, izvajati operacijo izkušenega zdravnika in strogo upoštevati zdravnikova navodila za pooperativno rehabilitacijo.
Topel opomnik: Ta članek je samo za referenco in ne more nadomestiti zdravnikovega strokovnega nasveta. Če imate kakršna koli vprašanja, se posvetujte s svojim zdravnikom.
Stik