RP1Z4
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
1.5 Orthognathic Micro 90°L-Plate | RP1Z416L1L | 4 holes, 0.6mm, 16mm, Left | |
RP1Z420L1L | 4 holes, 0.6mm, 20mm, Left | ||
RP1Z424L1L | 4 holes, 0.6mm, 24mm, Left | ||
RP1Z416L1R | 4 holes, 0.6mm, 16mm, Right | ||
RP1Z420L1R | 4 holes, 0.6mm, 20mm, Right | ||
RP1Z424L1R | 4 holes, 0.6mm, 24mm, Right |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Orthognathic Micro 90°L-Plate Product Catalog.
2. Choose Your Interested 1.5 Orthognathic Micro 90°L-Plate Product.
3. Ask For A Sample To Test 1.5 Orthognathic Micro 90°L-Plate.
4.Make An Order Of XC Medico's 1.5 Orthognathic Micro 90°L-Plate.
5.Become A Dealer Of XC Medico's 1.5 Orthognathic Micro 90°L-Plate.
1.Better Purchase Prices Of 1.5 Orthognathic Micro 90°L-Plate.
2.100% The Highest Quality 1.5 Orthognathic Micro 90°L-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Orthognathic Micro 90°L-Plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Orthognathic Micro 90°L-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Orthognathic surgery is a crucial intervention for correcting skeletal and dental irregularities in patients with malocclusion or jaw deformities. The 1.5 Orthognathic Mini 90°L-Plate is an advanced surgical device designed to aid in the fixation of bone fractures or in the stabilization of the maxillofacial region during reconstructive surgeries. This comprehensive guide will explore the features, advantages, surgical applications, and risks associated with the 1.5 Orthognathic Mini 90°L-Plate, offering essential insights for medical professionals, students, and researchers in the field of orthopedics and maxillofacial surgery.
The 1.5 Orthognathic Mini 90°L-Plate is a specialized surgical implant commonly used in maxillofacial surgery for the fixation of fractures or the stabilization of bone segments in the jaw and face. The "mini" designation refers to the plate’s compact design, making it ideal for smaller, more delicate bone structures, particularly in the maxillary and mandibular regions. The "90° L-Plate" name indicates the angular design of the plate, which provides enhanced stability and strength at the junction where two bone segments are realigned during surgery.
The 1.5 Orthognathic Mini 90°L-Plate is typically made from high-strength titanium alloy or stainless steel, ensuring durability and biocompatibility for long-term use. The plate is equipped with screw holes designed for precise fixation of the plate to the bone, and its 90-degree angle enables it to provide maximum support to the bone during the healing process.
The miniaturized size ensures minimal invasiveness, reducing the risk of complications and promoting faster recovery.
Constructed from titanium alloy or medical-grade stainless steel, the plate exhibits excellent mechanical strength, ensuring secure bone fixation and support during the healing phase.
The 90° angle design provides optimal alignment for fractured bone segments, enhancing the stability and efficacy of the surgical procedure.
The materials used in the plate are well-tolerated by the human body, reducing the risk of rejection or infection.
Designed for ease of use, the plate can be easily bent and adjusted to match the anatomical contours of the jaw and facial bones during surgery.
The smaller size and ergonomic design allow for a more minimally invasive surgical approach, reducing tissue trauma and enhancing recovery time.
The 90° design allows the plate to provide superior support to the bone structure, ensuring alignment is maintained throughout the healing process.
The precision of the plate reduces the need for complex adjustments during surgery, leading to quicker procedural times and reduced patient exposure to anesthesia.
Its compact design and efficient function minimize soft tissue damage, leading to a faster healing time and quicker return to normal function for the patient.
By minimizing tissue disruption and offering enhanced stability, the plate helps reduce the risk of postoperative complications such as malunion or nonunion of bone fragments.
Suitable for a wide range of fractures in the maxillofacial area, the 1.5 Orthognathic Mini 90°L-Plate can be used in both simple and complex fractures, as well as in reconstructive surgeries following trauma or congenital deformities.
It is effective in stabilizing fractures of the lower jaw, including fractures of the symphysis, angle, or body of the mandible. The plate's L-shaped design ensures a secure fixation that promotes proper alignment of the bone fragments.
The plate can be used in cases of fractures involving the upper jaw, including those that result from trauma or surgical interventions.
The plate can be used for fixation of fractures to the zygomatic bone or the orbital floor, stabilizing the facial skeleton after injury.
In cases of displaced fractures, the 90° angle design of the plate provides a mechanical advantage in restoring the bone to its correct anatomical position.
Following trauma, the plate serves as a temporary solution to hold the fractured bone segments in place, allowing for proper healing and integration of the bone during the recovery phase.
As with any surgical implant, there is a risk of infection at the surgical site. Prophylactic antibiotics are typically administered to reduce this risk.
In some cases, the plate may shift or migrate from its intended position, particularly if the fracture has not healed properly.
If the bone fragments do not heal properly, there is a risk of the bone failing to reunite (nonunion) or healing in an incorrect position (malunion).
Given the proximity of sensitive nerves in the maxillofacial region, there is a small risk of nerve injury during surgery.
Although rare, the plate itself can fracture under excessive stress or if the bone does not heal sufficiently to provide support.
In rare cases, patients may experience allergic reactions to the materials used in the plate, such as titanium or stainless steel.
With the rising incidence of facial fractures, trauma, and congenital deformities, the demand for reliable fixation devices like the 1.5 Orthognathic Mini 90°L-Plate will continue to rise.
As surgical techniques evolve, the demand for high-quality, innovative implants will increase. New materials, such as biocompatible polymers and 3D-printed plates, may be integrated into future versions of the plate.
As the global population ages, the need for reconstructive surgeries in the maxillofacial region due to osteoporotic fractures and age-related deformities will likely contribute to market growth.
Developing economies with improving healthcare infrastructures, such as China, India, and Brazil, will be significant contributors to the market expansion for orthopedic implants.
The 1.5 Orthognathic Mini 90°L-Plate represents a key advancement in maxillofacial and orthopedic surgery, offering a robust solution for the fixation of fractures and the stabilization of bone during reconstructive surgeries. With its compact design, high-strength material, and ease of application, the plate provides numerous advantages in terms of surgical efficiency, recovery time, and patient outcomes. Although there are inherent risks, such as infection and nerve damage, the benefits of the 1.5 Orthognathic Mini 90°L-Plate in treating complex fractures make it a valuable tool for healthcare professionals. The growing market for orthopedic and maxillofacial implants presents significant opportunities for the further development and integration of this device into surgical practice.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
1.5 Orthognathic Micro 90°L-Plate | RP1Z416L1L | 4 holes, 0.6mm, 16mm, Left | |
RP1Z420L1L | 4 holes, 0.6mm, 20mm, Left | ||
RP1Z424L1L | 4 holes, 0.6mm, 24mm, Left | ||
RP1Z416L1R | 4 holes, 0.6mm, 16mm, Right | ||
RP1Z420L1R | 4 holes, 0.6mm, 20mm, Right | ||
RP1Z424L1R | 4 holes, 0.6mm, 24mm, Right |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Orthognathic Micro 90°L-Plate Product Catalog.
2. Choose Your Interested 1.5 Orthognathic Micro 90°L-Plate Product.
3. Ask For A Sample To Test 1.5 Orthognathic Micro 90°L-Plate.
4.Make An Order Of XC Medico's 1.5 Orthognathic Micro 90°L-Plate.
5.Become A Dealer Of XC Medico's 1.5 Orthognathic Micro 90°L-Plate.
1.Better Purchase Prices Of 1.5 Orthognathic Micro 90°L-Plate.
2.100% The Highest Quality 1.5 Orthognathic Micro 90°L-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Orthognathic Micro 90°L-Plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Orthognathic Micro 90°L-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Orthognathic surgery is a crucial intervention for correcting skeletal and dental irregularities in patients with malocclusion or jaw deformities. The 1.5 Orthognathic Mini 90°L-Plate is an advanced surgical device designed to aid in the fixation of bone fractures or in the stabilization of the maxillofacial region during reconstructive surgeries. This comprehensive guide will explore the features, advantages, surgical applications, and risks associated with the 1.5 Orthognathic Mini 90°L-Plate, offering essential insights for medical professionals, students, and researchers in the field of orthopedics and maxillofacial surgery.
The 1.5 Orthognathic Mini 90°L-Plate is a specialized surgical implant commonly used in maxillofacial surgery for the fixation of fractures or the stabilization of bone segments in the jaw and face. The "mini" designation refers to the plate’s compact design, making it ideal for smaller, more delicate bone structures, particularly in the maxillary and mandibular regions. The "90° L-Plate" name indicates the angular design of the plate, which provides enhanced stability and strength at the junction where two bone segments are realigned during surgery.
The 1.5 Orthognathic Mini 90°L-Plate is typically made from high-strength titanium alloy or stainless steel, ensuring durability and biocompatibility for long-term use. The plate is equipped with screw holes designed for precise fixation of the plate to the bone, and its 90-degree angle enables it to provide maximum support to the bone during the healing process.
The miniaturized size ensures minimal invasiveness, reducing the risk of complications and promoting faster recovery.
Constructed from titanium alloy or medical-grade stainless steel, the plate exhibits excellent mechanical strength, ensuring secure bone fixation and support during the healing phase.
The 90° angle design provides optimal alignment for fractured bone segments, enhancing the stability and efficacy of the surgical procedure.
The materials used in the plate are well-tolerated by the human body, reducing the risk of rejection or infection.
Designed for ease of use, the plate can be easily bent and adjusted to match the anatomical contours of the jaw and facial bones during surgery.
The smaller size and ergonomic design allow for a more minimally invasive surgical approach, reducing tissue trauma and enhancing recovery time.
The 90° design allows the plate to provide superior support to the bone structure, ensuring alignment is maintained throughout the healing process.
The precision of the plate reduces the need for complex adjustments during surgery, leading to quicker procedural times and reduced patient exposure to anesthesia.
Its compact design and efficient function minimize soft tissue damage, leading to a faster healing time and quicker return to normal function for the patient.
By minimizing tissue disruption and offering enhanced stability, the plate helps reduce the risk of postoperative complications such as malunion or nonunion of bone fragments.
Suitable for a wide range of fractures in the maxillofacial area, the 1.5 Orthognathic Mini 90°L-Plate can be used in both simple and complex fractures, as well as in reconstructive surgeries following trauma or congenital deformities.
It is effective in stabilizing fractures of the lower jaw, including fractures of the symphysis, angle, or body of the mandible. The plate's L-shaped design ensures a secure fixation that promotes proper alignment of the bone fragments.
The plate can be used in cases of fractures involving the upper jaw, including those that result from trauma or surgical interventions.
The plate can be used for fixation of fractures to the zygomatic bone or the orbital floor, stabilizing the facial skeleton after injury.
In cases of displaced fractures, the 90° angle design of the plate provides a mechanical advantage in restoring the bone to its correct anatomical position.
Following trauma, the plate serves as a temporary solution to hold the fractured bone segments in place, allowing for proper healing and integration of the bone during the recovery phase.
As with any surgical implant, there is a risk of infection at the surgical site. Prophylactic antibiotics are typically administered to reduce this risk.
In some cases, the plate may shift or migrate from its intended position, particularly if the fracture has not healed properly.
If the bone fragments do not heal properly, there is a risk of the bone failing to reunite (nonunion) or healing in an incorrect position (malunion).
Given the proximity of sensitive nerves in the maxillofacial region, there is a small risk of nerve injury during surgery.
Although rare, the plate itself can fracture under excessive stress or if the bone does not heal sufficiently to provide support.
In rare cases, patients may experience allergic reactions to the materials used in the plate, such as titanium or stainless steel.
With the rising incidence of facial fractures, trauma, and congenital deformities, the demand for reliable fixation devices like the 1.5 Orthognathic Mini 90°L-Plate will continue to rise.
As surgical techniques evolve, the demand for high-quality, innovative implants will increase. New materials, such as biocompatible polymers and 3D-printed plates, may be integrated into future versions of the plate.
As the global population ages, the need for reconstructive surgeries in the maxillofacial region due to osteoporotic fractures and age-related deformities will likely contribute to market growth.
Developing economies with improving healthcare infrastructures, such as China, India, and Brazil, will be significant contributors to the market expansion for orthopedic implants.
The 1.5 Orthognathic Mini 90°L-Plate represents a key advancement in maxillofacial and orthopedic surgery, offering a robust solution for the fixation of fractures and the stabilization of bone during reconstructive surgeries. With its compact design, high-strength material, and ease of application, the plate provides numerous advantages in terms of surgical efficiency, recovery time, and patient outcomes. Although there are inherent risks, such as infection and nerve damage, the benefits of the 1.5 Orthognathic Mini 90°L-Plate in treating complex fractures make it a valuable tool for healthcare professionals. The growing market for orthopedic and maxillofacial implants presents significant opportunities for the further development and integration of this device into surgical practice.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact