2.0 Orthognathic Mini Anatomical L-Plate

  • RP3ZJ

  • XCmedico

  • 1 Pcs(72 Hours Delivery)

  • Titanium  Alloy

  • CE/ISO:9001/ISO13485.Etc

  • Custom-Made 15 Days Delivery(Excluding Shipping Time)

  • FedEx. DHL.TNT.EMS.Etc

Availability:
Quantity:

2.0 Orthognathic Mini Anatomical L-Plate Video


2.0 Orthognathic Mini Anatomical L-Plate PDF

        

2.0 Orthognathic Mini Anatomical L-Plate Specification

Name Picture Item No. Specification
2.0 Orthognathic Mini Anatomical L-Plate 2.0 Orthognathic Mini Anatomical L-Plate RP3ZJ622L 6 holes, 1.0mm, 22mm
RP3ZJ624L 6 holes, 1.0mm, 24mm
RP3ZJ625L 6 holes, 1.0mm, 25mm



Advantages of  XC Medico's Products

Initial product processing

      CNC Preliminary Processing


The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans.


Polishing products

           Product Polishing




The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant.

Quality Inspection

          Quality Inspection



The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability.

Product package

          Product Package


Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety.

Productwarehouse        Product  Warehouse


The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment.

sample room           Sample Room


The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training.



The Process To Cooperate With XC Medico 

1. Ask Xc Medico Team For 2.0 Orthognathic Mini Anatomical L-Plate Product Catalog.


2. Choose Your Interested 2.0 Orthognathic Mini Anatomical L-Plate Product.


3. Ask For A Sample To Test 2.0 Orthognathic Mini Anatomical L-Plate.


4.Make An Order Of XC Medico's 2.0 Orthognathic Mini Anatomical L-Plate.


5.Become A Dealer Of XC Medico's 2.0 Orthognathic Mini Anatomical L-Plate.



The Advantages To Be A Dealer Or Wholesaler Of  XC Medico

1.Better Purchase Prices Of 2.0 Orthognathic Mini Anatomical L-Plate.


2.100% The Highest Quality 2.0 Orthognathic Mini Anatomical L-Plate.


3. Less Ordering Efforts.


4. Price Stability For The Period Of Agreement.


5. Sufficient 2.0 Orthognathic Mini Anatomical L-Plate.


6. Quick And Easy Assessment Of XC Medico's 2.0 Orthognathic Mini Anatomical L-Plate.


7. A Globally Recognized Brand - XC Medico.


8. Fast Access Time To XC Medico Sales Team.


9. Additional Quality Test By XC Medico Team.


10. Track Your XC Medico Order From Start To Finish.



2.0 Orthognathic Mini Anatomical L-Plate : A Comprehensive Guide

The 2.0 Orthognathic Mini Anatomical L-Plate is a specialized titanium implant designed for use in orthognathic surgery, particularly for correcting mandibular deformities or fractures. This plate is widely used in both trauma cases and aesthetic corrections, providing precise fixation of bone segments, enhancing healing, and restoring both function and appearance. In this comprehensive guide, we will explore the key features, advantages, and potential future market growth for the 2.0 Orthognathic Mini Anatomical L-Plate.



What is 2.0 Orthognathic Mini Anatomical L-Plate

The 2.0 Orthognathic Mini Anatomical L-Plate is a small and precisely designed implant used primarily in maxillofacial and orthognathic surgeries. It is a miniature version of a traditional L-plate, made from biocompatible titanium to ensure optimal strength, durability, and integration with the patient’s bone. This plate is typically 2.0 mm thick and specifically shaped to fit the anatomy of the mandible, offering enhanced stability during surgical procedures.


The L-shape of the plate is specifically designed to provide secure fixation at the angle of the mandible, which is a critical area in many fractures and osteotomy procedures. Its miniaturized design makes it an ideal choice for minimally invasive surgeries and for cases where smaller, more delicate plates are required to minimize tissue trauma while maintaining structural support.



2.0 Orthognathic Mini Anatomical L-Plate Features

Anatomical Design

The L-plate is designed to conform to the natural contours of the mandible, ensuring that it fits precisely at the angle or body of the mandible, minimizing the need for extensive modification during surgery.

Material Composition

Made from biocompatible titanium, this plate offers excellent strength, durability, and resistance to corrosion. Titanium's low weight and high strength-to-weight ratio ensure that the plate provides sufficient support without adding undue weight or burden to the surgical site.

Miniature Size

The 2.0 thickness of the plate allows for minimally invasive procedures, enabling precise fixation with minimal disruption to the surrounding tissue. This reduces the risk of complications and enhances the healing process.

Pre-Drilled Holes

The plate comes with pre-drilled holes, strategically positioned for optimal screw placement. These holes simplify the surgical procedure, providing accurate and secure screw placement without the need for additional adjustments.

Versatility

While commonly used in orthognathic surgeries for jaw correction, the 2.0 Orthognathic Mini Anatomical L-Plate is also used for fracture fixation in mandibular trauma cases, making it a versatile tool in oral and maxillofacial surgery.

Low Profile

The slim design of the plate helps minimize soft tissue irritation, ensuring better comfort for the patient and reducing post-operative complications.



2.0 Orthognathic Mini Anatomical L-Plate Advantages

Enhanced Stability

The precise fit and strong fixation capabilities of the L-Plate ensure that the mandibular bones are securely aligned during the healing process, promoting faster recovery and reducing the chances of misalignment or non-union.

Minimally Invasive Approach

Due to the miniaturized nature of the plate, the 2.0 Orthognathic Mini Anatomical L-Plate enables minimally invasive surgical procedures, reducing the need for extensive incisions and minimizing trauma to soft tissues. This leads to quicker recovery, less swelling, and a lower risk of complications such as infection.

Improved Aesthetic and Functional Outcomes

By offering precise fixation during orthognathic surgery, the plate helps correct jaw deformities, leading to improved aesthetic appearance and functional restoration of the jaw. This is especially important for patients undergoing surgery for cosmetic reasons or for those who have jaw-related functional impairments.

Reduced Post-Operative Pain and Recovery Time

The low profile and reduced size of the plate minimize soft tissue irritation and discomfort. As a result, patients often experience less pain and faster recovery times compared to larger, more invasive plates.

Reduced Risk of Infection

The titanium material reduces the risk of biological rejection or infection and is highly resistant to corrosion. Its biocompatibility ensures that the plate integrates well with the surrounding bone, promoting faster healing and reducing the chances of post-surgical complications.

Excellent Patient Comfort

The anatomical shape and low profile design minimize irritation to the surrounding soft tissues, ensuring greater comfort for the patient, especially during the post-operative period.



2.0 Orthognathic Mini Anatomical L-Plate Treatment of Fracture Types

Mandibular Angle Fractures

These fractures, often caused by trauma, occur at the angle of the mandible and are a common site for injury. The anatomical L-plate provides stable fixation to restore the alignment of the fractured bone segments.

Mandibular Body Fractures

Fractures in the body of the mandible are often treated using this plate to align the fractured bone segments accurately and provide support during the healing process.

Orthognathic Surgery

For patients undergoing jaw realignment surgery (BSSO, LeFort I osteotomy, etc.), the 2.0 Orthognathic Mini Anatomical L-Plate is ideal for stabilizing the bones and ensuring the success of the procedure, both functionally and aesthetically.

Post-Traumatic Reconstruction

In patients with complex jaw fractures resulting from trauma, this plate aids in reconstructing the mandible and providing the stability needed for proper healing.

Displaced Fractures

The mini anatomical L-plate offers a precise fixation technique, ensuring displaced fractures are securely aligned, reducing the risk of complications such as malunion or nonunion.



Risks of 2.0 Orthognathic Mini Anatomical L-Plate Surgery

Infection

Despite the use of biocompatible materials, there is still a risk of post-surgical infections, particularly if the surgical site is not adequately sterilized or the patient has underlying health conditions.

Nerve Damage

The close proximity of cranial nerves, such as the inferior alveolar nerve, can lead to complications like numbness, tingling, or loss of sensation in the lower lip or chin.

Plate Loosening or Failure

Over time, the plate or screws may loosen, particularly if bone healing is delayed or the patient engages in excessive physical activity. This may necessitate additional surgery to replace the plate.

Malunion or Nonunion

If the plate does not provide adequate stabilization, the bone fragments may fail to heal properly, leading to misalignment (malunion) or no healing at all (nonunion).

Swelling and Pain

While rare, some patients may experience swelling, pain, or discomfort around the implant site, particularly during the recovery phase.

Hardware Complications

 In some cases, the plate or screws may cause irritation to surrounding tissues, or the plate may fracture due to excessive force or abnormal bone healing.



2.0 Orthognathic Mini Anatomical L-Plate Future Marke

Rising Demand for Orthognathic Surgery

With increasing awareness of the importance of both aesthetic and functional outcomes in facial surgeries, there is an anticipated growth in the demand for orthognathic surgery, driving the need for advanced implant technologies such as the 2.0 Orthognathic Mini Anatomical L-Plate.

Technological Advancements

The development of new materials and 3D printing technologies for custom implants will likely increase the demand for more personalized and precise solutions, further boosting the adoption of miniaturized plates like the 2.0 Orthognathic Mini Anatomical L-Plate.

Aesthetic Surgery Market

As more individuals seek corrective surgeries for jaw alignment and facial aesthetics, the market for minimally invasive surgical tools, including the 2.0 Orthognathic Mini Anatomical L-Plate, will continue to expand.

Global Expansion

The growing healthcare infrastructure in emerging markets, along with a rise in disposable income, will facilitate increased adoption of advanced orthopedic implants and devices, supporting the global growth of the 2.0 Orthognathic Mini Anatomical L-Plate market.



Summary

The 2.0 Orthognathic Mini Anatomical L-Plate is an innovative and versatile solution in maxillofacial surgery, offering exceptional stability and precision in treating mandibular fractures and undergoing orthognathic procedures. Its anatomical design, biocompatible materials, and miniaturized structure make it an ideal choice for minimally invasive surgeries, ensuring both functional and aesthetic recovery for patients. While surgical risks exist, they can be managed effectively with proper technique and post-operative care. As demand for both trauma repair and cosmetic jaw procedures continues to grow, the market for the 2.0 Orthognathic Mini Anatomical L-Plate is expected to expand, solidifying its role in modern orthognathic and reconstructive surgery.


Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.

Previous: 
Next: 

Contact With Us Now!

We have an extremely strict delivery process,from sample approval to final product delivery, and then to shipment confirmation, which allow us more close to your accurate demand and requirement.
XC Medico is leading orthopedic implants and instruments distributor and manufacturer in China. We provide trauma systems, spine systems, CMF/maxillofacial systems, sport medicine systems, joint systems, external fixator systems, orthopedic instruments, and medical power tools.

Quick Links

Contact

Tianan Cyber City, Changwu Middle Road, Changzhou, China
86-18961187889

Keep In Touch

To know more about XC Medico, please subscribe our Youtube channel, or follow us on Linkedin or Facebook. We’ll keep updating our information for you.
© COPYRIGHT 2024 CHANGZHOU XC MEDICO TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.