RSQSP
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | REF | Specification |
4.0mm Cancellous Screw (full threaded) | RSQSP4012 | 4.0*12mm | |
RSQSP4014 | 4.0*14mm | ||
RSQSP4016 | 4.0*16mm | ||
RSQSP4018 | 4.0*18mm | ||
RSQSP4020 | 4.0*20mm | ||
RSQSP4022 | 4.0*22mm | ||
RSQSP4024 | 4.0*24mm | ||
RSQSP4026 | 4.0*26mm | ||
RSQSP4028 | 4.0*28mm | ||
RSQSP4030 | 4.0*30mm | ||
RSQSP4032 | 4.0*32mm | ||
RSQSP4034 | 4.0*34mm | ||
RSQSP4036 | 4.0*36mm | ||
RSQSP4038 | 4.0*38mm | ||
RSQSP4040 | 4.0*40mm | ||
RSQSP4042 | 4.0*42mm | ||
RSQSP4044 | 4.0*44mm | ||
RSQSP4046 | 4.0*46mm | ||
RSQSP4048 | 4.0*48mm | ||
RSQSP4050 | 4.0*50mm | ||
6.5 Cancellous Screw (full threaded) | RSQSP6550 | 6.5*50mm | |
RSQSP6555 | 6.5*55mm | ||
RSQSP6560 | 6.5*60mm | ||
RSQSP6565 | 6.5*65mm | ||
RSQSP6570 | 6.5*70mm | ||
RSQSP6575 | 6.5*75mm | ||
RSQSP6580 | 6.5*80mm | ||
RSQSP6585 | 6.5*85mm | ||
RSQSP6590 | 6.5*90mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 4.0/6.5mm Cancellous Screw Product Catalog.
2. Choose Your Interested 4.0/6.5mm Cancellous Screw Product.
3. Ask For A Sample To Test 4.0/6.5mm Cancellous Screw Plate.
4.Make An Order Of XC Medico's 4.0/6.5mm Cancellous Screw Plate.
5.Become A Dealer Of XC Medico's 4.0/6.5mm Cancellous Screw Plate.
1.Better Purchase Prices Of 4.0/6.5mm Cancellous Screw Plate.
2.100% The Highest Quality 4.0/6.5mm Cancellous Screw Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 4.0/6.5mm Cancellous Screw Plate.
6. Quick And Easy Assessment Of XC Medico's 4.0/6.5mm Cancellous Screw Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 4.0/6.5mm Cancellous Screw is a specialized orthopedic implant designed for use in cancellous bone, which is less dense and more porous than cortical bone. These screws provide strong purchase in cancellous bone due to their wider threads, making them ideal for fixation in metaphyseal regions or for compression at fracture sites. This guide explores the features, concepts, and applications of cancellous screws in modern orthopedic surgery, offering insights for patients, medical professionals, and researchers.
The 4.0/6.5mm Cancellous Screw is a threaded orthopedic implant optimized for fixation in cancellous bone. The screw’s diameter—4.0mm or 6.5mm—determines its application, with smaller sizes used for delicate anatomical regions like the wrist, and larger sizes applied to load-bearing areas such as the pelvis or proximal femur. These screws can function independently or as part of a fixation system, providing compression and stabilization for fracture healing.
Enhances grip in porous cancellous bone, ensuring stable fixation.
Partially threaded screws provide compression across fracture sites, while fully threaded screws offer uniform stabilization.
Simplifies insertion by cutting threads during placement, reducing operative time.
Typically made from titanium or stainless steel for strength, corrosion resistance, and compatibility with biological tissues.
Facilitates guided placement over a guidewire for precision in minimally invasive procedures.
Wide threads provide superior grip in cancellous bone, ensuring stable fixation.
Partially threaded screws effectively compress fracture fragments, accelerating healing.
Available in various sizes and designs, making it suitable for multiple anatomical regions and fracture types.
Self-tapping tips simplify insertion, reducing the need for pre-drilling in many cases.
Cannulated designs allow for precise placement with minimal disruption to surrounding tissues.
Provides secure fixation in regions with a high proportion of cancellous bone.
Generates stability and promotes healing through effective compression.
Stabilizes articular cartilage and bone in joint injuries.
Larger screws are used to stabilize the pelvis and sacroiliac joints.
Often used in conjunction with plates or nails for enhanced fixation.
Postoperative infections, though rare, require stringent aseptic protocols.
High mechanical loads or poor bone quality can compromise fixation.
Improper placement or insufficient compression may hinder proper healing.
Screws placed too superficially can cause discomfort or damage to surrounding tissues.
Misplacement near critical structures increases the risk of complications.
The 4.0/6.5mm Cancellous Screw is poised for continued growth and innovation in the global orthopedic implant market.
Advancements in materials science may lead to bioactive coatings that enhance bone integration and healing. The adoption of patient-specific screws through 3D printing technology will further improve surgical precision. As minimally invasive techniques gain popularity, the demand for cannulated screws is expected to rise. With an increasing global incidence of fractures due to aging populations and trauma, the cancellous screw market is set to expand significantly.
The 4.0/6.5mm Cancellous Screw is a vital component of modern orthopedic surgery, providing effective fixation in cancellous bone regions. Its ability to offer stability, compression, and versatility makes it indispensable for fracture management. With ongoing advancements in design and material science, cancellous screws will continue to play a pivotal role in enhancing surgical outcomes and improving patient care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | REF | Specification |
4.0mm Cancellous Screw (full threaded) | RSQSP4012 | 4.0*12mm | |
RSQSP4014 | 4.0*14mm | ||
RSQSP4016 | 4.0*16mm | ||
RSQSP4018 | 4.0*18mm | ||
RSQSP4020 | 4.0*20mm | ||
RSQSP4022 | 4.0*22mm | ||
RSQSP4024 | 4.0*24mm | ||
RSQSP4026 | 4.0*26mm | ||
RSQSP4028 | 4.0*28mm | ||
RSQSP4030 | 4.0*30mm | ||
RSQSP4032 | 4.0*32mm | ||
RSQSP4034 | 4.0*34mm | ||
RSQSP4036 | 4.0*36mm | ||
RSQSP4038 | 4.0*38mm | ||
RSQSP4040 | 4.0*40mm | ||
RSQSP4042 | 4.0*42mm | ||
RSQSP4044 | 4.0*44mm | ||
RSQSP4046 | 4.0*46mm | ||
RSQSP4048 | 4.0*48mm | ||
RSQSP4050 | 4.0*50mm | ||
6.5 Cancellous Screw (full threaded) | RSQSP6550 | 6.5*50mm | |
RSQSP6555 | 6.5*55mm | ||
RSQSP6560 | 6.5*60mm | ||
RSQSP6565 | 6.5*65mm | ||
RSQSP6570 | 6.5*70mm | ||
RSQSP6575 | 6.5*75mm | ||
RSQSP6580 | 6.5*80mm | ||
RSQSP6585 | 6.5*85mm | ||
RSQSP6590 | 6.5*90mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 4.0/6.5mm Cancellous Screw Product Catalog.
2. Choose Your Interested 4.0/6.5mm Cancellous Screw Product.
3. Ask For A Sample To Test 4.0/6.5mm Cancellous Screw Plate.
4.Make An Order Of XC Medico's 4.0/6.5mm Cancellous Screw Plate.
5.Become A Dealer Of XC Medico's 4.0/6.5mm Cancellous Screw Plate.
1.Better Purchase Prices Of 4.0/6.5mm Cancellous Screw Plate.
2.100% The Highest Quality 4.0/6.5mm Cancellous Screw Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 4.0/6.5mm Cancellous Screw Plate.
6. Quick And Easy Assessment Of XC Medico's 4.0/6.5mm Cancellous Screw Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 4.0/6.5mm Cancellous Screw is a specialized orthopedic implant designed for use in cancellous bone, which is less dense and more porous than cortical bone. These screws provide strong purchase in cancellous bone due to their wider threads, making them ideal for fixation in metaphyseal regions or for compression at fracture sites. This guide explores the features, concepts, and applications of cancellous screws in modern orthopedic surgery, offering insights for patients, medical professionals, and researchers.
The 4.0/6.5mm Cancellous Screw is a threaded orthopedic implant optimized for fixation in cancellous bone. The screw’s diameter—4.0mm or 6.5mm—determines its application, with smaller sizes used for delicate anatomical regions like the wrist, and larger sizes applied to load-bearing areas such as the pelvis or proximal femur. These screws can function independently or as part of a fixation system, providing compression and stabilization for fracture healing.
Enhances grip in porous cancellous bone, ensuring stable fixation.
Partially threaded screws provide compression across fracture sites, while fully threaded screws offer uniform stabilization.
Simplifies insertion by cutting threads during placement, reducing operative time.
Typically made from titanium or stainless steel for strength, corrosion resistance, and compatibility with biological tissues.
Facilitates guided placement over a guidewire for precision in minimally invasive procedures.
Wide threads provide superior grip in cancellous bone, ensuring stable fixation.
Partially threaded screws effectively compress fracture fragments, accelerating healing.
Available in various sizes and designs, making it suitable for multiple anatomical regions and fracture types.
Self-tapping tips simplify insertion, reducing the need for pre-drilling in many cases.
Cannulated designs allow for precise placement with minimal disruption to surrounding tissues.
Provides secure fixation in regions with a high proportion of cancellous bone.
Generates stability and promotes healing through effective compression.
Stabilizes articular cartilage and bone in joint injuries.
Larger screws are used to stabilize the pelvis and sacroiliac joints.
Often used in conjunction with plates or nails for enhanced fixation.
Postoperative infections, though rare, require stringent aseptic protocols.
High mechanical loads or poor bone quality can compromise fixation.
Improper placement or insufficient compression may hinder proper healing.
Screws placed too superficially can cause discomfort or damage to surrounding tissues.
Misplacement near critical structures increases the risk of complications.
The 4.0/6.5mm Cancellous Screw is poised for continued growth and innovation in the global orthopedic implant market.
Advancements in materials science may lead to bioactive coatings that enhance bone integration and healing. The adoption of patient-specific screws through 3D printing technology will further improve surgical precision. As minimally invasive techniques gain popularity, the demand for cannulated screws is expected to rise. With an increasing global incidence of fractures due to aging populations and trauma, the cancellous screw market is set to expand significantly.
The 4.0/6.5mm Cancellous Screw is a vital component of modern orthopedic surgery, providing effective fixation in cancellous bone regions. Its ability to offer stability, compression, and versatility makes it indispensable for fracture management. With ongoing advancements in design and material science, cancellous screws will continue to play a pivotal role in enhancing surgical outcomes and improving patient care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact