GX203006
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Combination | Name | NO. | Size | Picture | Qty. | ||
Double rods tuberosity Combinational fixator C type | Double rods pin clamp | 203003-0845 | φ8/4-5 | 5 | |||
Connecting rod | SS08-300 | φ8×300 | 2 | ||||
Bone screws | SS10501345 | φ5×130 | 2 | ||||
Bone screws | SS10501850 | φ5×180 | 3 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Double rods tuberosity Combinational fixator C type Product Catalog.
2. Choose Your Interested Double rods tuberosity Combinational fixator C type Product.
3. Ask For A Sample To Test Double rods tuberosity Combinational fixator C type.
4.Make An Order Of XC Medico's Double rods tuberosity Combinational fixator C type.
5.Become A Dealer Of XC Medico's Double rods tuberosity Combinational fixator C type.
1.Better Purchase Prices Of Double rods tuberosity Combinational fixator C type.
2.100% The Highest Quality Double rods tuberosity Combinational fixator C type.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Double rods tuberosity Combinational fixator C type.
6. Quick And Easy Assessment Of XC Medico's Double rods tuberosity Combinational fixator C type.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The Double Rods Tuberosity Combinational Fixator C Type is an advanced orthopedic device specifically designed to provide superior stabilization for complex fractures and deformities in weight-bearing bones. Its unique dual-rod configuration enhances structural integrity, making it ideal for managing high-stress areas such as the tibial tuberosity or similar anatomical regions. This comprehensive guide explores the features, applications, advantages, and future potential of this innovative fixation system.
The Double Rods Tuberosity Combinational Fixator C Type is an external fixation device designed for fractures and deformities that involve high-stress anatomical regions, particularly those requiring enhanced stability, such as the tibial tuberosity. The "C Type" denotes the semi-circular frame design, which conforms to the natural curvature of the body, providing ergonomic support and precise alignment.
This fixator incorporates dual rods, which distribute mechanical forces evenly, reducing stress on the bone and surrounding soft tissues. It is particularly effective for open fractures, comminuted fractures, and cases requiring deformity correction or gradual realignment.
Provides superior mechanical stability and ensures even distribution of forces, reducing the risk of complications during recovery.
Conforms to the natural curvature of the limb, ensuring secure and ergonomic fixation.
Allows for fine-tuned adjustments during and after surgery to maintain proper alignment throughout the healing process.
Made from titanium or stainless steel for durability, patient comfort, and reduced risk of infection.
Ensures compatibility with imaging modalities, enabling accurate assessment of fracture healing.
The system is adaptable for different fracture patterns and anatomical regions, providing tailored solutions for diverse cases.
The dual rods provide exceptional support for high-stress areas, preventing displacement and ensuring proper alignment.
The external application minimizes trauma to surrounding tissues, preserving the integrity of muscles, tendons, and nerves.
The external design is ideal for open fractures, as it avoids placing hardware directly in the fracture site, lowering the risk of deep infections.
Surgeons can make postoperative modifications without additional surgeries, allowing for gradual corrections as needed.
The robust fixation allows patients to begin weight-bearing exercises earlier, promoting faster recovery.
Suitable for a wide range of fractures and deformities, including those requiring gradual correction or distraction osteogenesis.
Stabilizes fractures with multiple bone fragments, ensuring proper alignment and healing.
Provides secure fixation while accommodating wound care and minimizing infection risks.
Maintains alignment near joint surfaces, preserving functionality and preventing deformities.
Offers targeted stabilization for high-stress fractures in weight-bearing regions.
Enables gradual correction of angular or rotational deformities caused by trauma.
Supports distraction osteogenesis for controlled bone lengthening and regeneration.
The external pins may become infected if not properly maintained, requiring diligent hygiene and monitoring.
Suboptimal alignment or patient non-compliance can slow or prevent proper fracture healing.
The external components may cause discomfort or inflammation in adjacent tissues.
Rare cases of pin loosening or frame instability may necessitate adjustment or replacement.
Prolonged immobilization without appropriate rehabilitation may lead to reduced range of motion.
The visible and prolonged nature of the fixator may affect patient adherence to postoperative care protocols.
Rising rates of road accidents, workplace injuries, and sports-related trauma are driving demand for advanced fixation solutions.
The global rise in elderly populations is contributing to a higher prevalence of fractures and degenerative conditions.
Innovations in materials, design, and imaging compatibility are enhancing the effectiveness and comfort of external fixators.
Growing preference for less invasive treatments is promoting the use of external fixation systems.
Expanding healthcare infrastructure in developing regions is increasing access to advanced orthopedic devices.
The Double Rods Tuberosity Combinational Fixator C Type is a state-of-the-art device that provides exceptional stabilization for complex fractures and deformities in high-stress anatomical regions. Its dual-rod design, advanced features, and numerous advantages make it an indispensable tool in modern orthopedic surgery. While there are potential risks associated with its use, proper planning and diligent care ensure successful outcomes. As technological advancements and market demand continue to grow, this fixator is poised to play a pivotal role in improving patient outcomes and advancing orthopedic care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Combination | Name | NO. | Size | Picture | Qty. | ||
Double rods tuberosity Combinational fixator C type | Double rods pin clamp | 203003-0845 | φ8/4-5 | 5 | |||
Connecting rod | SS08-300 | φ8×300 | 2 | ||||
Bone screws | SS10501345 | φ5×130 | 2 | ||||
Bone screws | SS10501850 | φ5×180 | 3 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Double rods tuberosity Combinational fixator C type Product Catalog.
2. Choose Your Interested Double rods tuberosity Combinational fixator C type Product.
3. Ask For A Sample To Test Double rods tuberosity Combinational fixator C type.
4.Make An Order Of XC Medico's Double rods tuberosity Combinational fixator C type.
5.Become A Dealer Of XC Medico's Double rods tuberosity Combinational fixator C type.
1.Better Purchase Prices Of Double rods tuberosity Combinational fixator C type.
2.100% The Highest Quality Double rods tuberosity Combinational fixator C type.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Double rods tuberosity Combinational fixator C type.
6. Quick And Easy Assessment Of XC Medico's Double rods tuberosity Combinational fixator C type.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The Double Rods Tuberosity Combinational Fixator C Type is an advanced orthopedic device specifically designed to provide superior stabilization for complex fractures and deformities in weight-bearing bones. Its unique dual-rod configuration enhances structural integrity, making it ideal for managing high-stress areas such as the tibial tuberosity or similar anatomical regions. This comprehensive guide explores the features, applications, advantages, and future potential of this innovative fixation system.
The Double Rods Tuberosity Combinational Fixator C Type is an external fixation device designed for fractures and deformities that involve high-stress anatomical regions, particularly those requiring enhanced stability, such as the tibial tuberosity. The "C Type" denotes the semi-circular frame design, which conforms to the natural curvature of the body, providing ergonomic support and precise alignment.
This fixator incorporates dual rods, which distribute mechanical forces evenly, reducing stress on the bone and surrounding soft tissues. It is particularly effective for open fractures, comminuted fractures, and cases requiring deformity correction or gradual realignment.
Provides superior mechanical stability and ensures even distribution of forces, reducing the risk of complications during recovery.
Conforms to the natural curvature of the limb, ensuring secure and ergonomic fixation.
Allows for fine-tuned adjustments during and after surgery to maintain proper alignment throughout the healing process.
Made from titanium or stainless steel for durability, patient comfort, and reduced risk of infection.
Ensures compatibility with imaging modalities, enabling accurate assessment of fracture healing.
The system is adaptable for different fracture patterns and anatomical regions, providing tailored solutions for diverse cases.
The dual rods provide exceptional support for high-stress areas, preventing displacement and ensuring proper alignment.
The external application minimizes trauma to surrounding tissues, preserving the integrity of muscles, tendons, and nerves.
The external design is ideal for open fractures, as it avoids placing hardware directly in the fracture site, lowering the risk of deep infections.
Surgeons can make postoperative modifications without additional surgeries, allowing for gradual corrections as needed.
The robust fixation allows patients to begin weight-bearing exercises earlier, promoting faster recovery.
Suitable for a wide range of fractures and deformities, including those requiring gradual correction or distraction osteogenesis.
Stabilizes fractures with multiple bone fragments, ensuring proper alignment and healing.
Provides secure fixation while accommodating wound care and minimizing infection risks.
Maintains alignment near joint surfaces, preserving functionality and preventing deformities.
Offers targeted stabilization for high-stress fractures in weight-bearing regions.
Enables gradual correction of angular or rotational deformities caused by trauma.
Supports distraction osteogenesis for controlled bone lengthening and regeneration.
The external pins may become infected if not properly maintained, requiring diligent hygiene and monitoring.
Suboptimal alignment or patient non-compliance can slow or prevent proper fracture healing.
The external components may cause discomfort or inflammation in adjacent tissues.
Rare cases of pin loosening or frame instability may necessitate adjustment or replacement.
Prolonged immobilization without appropriate rehabilitation may lead to reduced range of motion.
The visible and prolonged nature of the fixator may affect patient adherence to postoperative care protocols.
Rising rates of road accidents, workplace injuries, and sports-related trauma are driving demand for advanced fixation solutions.
The global rise in elderly populations is contributing to a higher prevalence of fractures and degenerative conditions.
Innovations in materials, design, and imaging compatibility are enhancing the effectiveness and comfort of external fixators.
Growing preference for less invasive treatments is promoting the use of external fixation systems.
Expanding healthcare infrastructure in developing regions is increasing access to advanced orthopedic devices.
The Double Rods Tuberosity Combinational Fixator C Type is a state-of-the-art device that provides exceptional stabilization for complex fractures and deformities in high-stress anatomical regions. Its dual-rod design, advanced features, and numerous advantages make it an indispensable tool in modern orthopedic surgery. While there are potential risks associated with its use, proper planning and diligent care ensure successful outcomes. As technological advancements and market demand continue to grow, this fixator is poised to play a pivotal role in improving patient outcomes and advancing orthopedic care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact