R6ZDD
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | REF | Specification | |
6.0 Monoaxial Pedicle Screw | R6ZDD4525 | Ф4.5×25mm | ||
R6ZDD4530 | Ф4.5×30mm | |||
R6ZDD4535 | Ф4.5×35mm | |||
R6ZDD4540 | Ф4.5×40mm | |||
R6ZDD4545 | Ф4.5×45mm | |||
R6ZDD5030 | Ф5.0×30mm | |||
R6ZDD5035 | Ф5.0×35mm | |||
R6ZDD5040 | Ф5.0×40mm | |||
R6ZDD5045 | Ф5.0×45mm | |||
R6ZDD5530 | Ф5.5×30mm | |||
R6ZDD5535 | Ф5.5×35mm | |||
R6ZDD5540 | Ф5.5×40mm | |||
R6ZDD5545 | Ф5.5×45mm | |||
R6ZDD5550 | Ф5.5×50mm | |||
R6ZDD6030 | Ф6.0×30mm | |||
R6ZDD6035 | Ф6.0×35mm | |||
R6ZDD6040 | Ф6.0×40mm | |||
R6ZDD6045 | Ф6.0×45mm | |||
R6ZDD6050 | Ф6.0×50mm | |||
R6ZDD6530 | Ф6.5×30mm | |||
R6ZDD6535 | Ф6.5×35mm | |||
R6ZDD6540 | Ф6.5×40mm | |||
R6ZDD6545 | Ф6.5×45mm | |||
R6ZDD6550 | Ф6.5×50mm | |||
R6ZDD7035 | Ф7.0x35mm | |||
R6ZDD7040 | Ф7.0x40mm | |||
R6ZDD7045 | Ф7.0x45mm | |||
R6ZDD7050 | Ф7.0x50mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 6.0 Monoaxial Pedicle Screw Product Catalog.
2. Choose Your Interested 6.0 Monoaxial Pedicle Screw Product.
3. Ask For A Sample To Test 6.0 Monoaxial Pedicle Screw.
4.Make An Order Of XC Medico's 6.0 Monoaxial Pedicle Screw.
5.Become A Dealer Of XC Medico's 6.0 Monoaxial Pedicle Screw.
1.Better Purchase Prices Of 6.0 Monoaxial Pedicle Screw.
2.100% The Highest Quality 6.0 Monoaxial Pedicle Screw.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 6.0 Monoaxial Pedicle Screw.
6. Quick And Easy Assessment Of XC Medico's 6.0 Monoaxial Pedicle Screw.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 6.0 monoaxial pedicle screw is a cornerstone in spinal fixation systems, renowned for its stability and versatility in treating various spinal pathologies. Designed for precision and durability, this implant plays a critical role in spinal deformity correction, trauma stabilization, and degenerative spine surgeries. This guide provides an in-depth exploration of its features, applications, and future prospects, catering to the needs of orthopedic professionals, medical students, and researchers.
The 6.0 monoaxial pedicle screw is a spinal implant used in posterior fixation systems. "Monoaxial" refers to its rigid, fixed-angle design, providing stable support in a single axis. With a diameter of 6.0 mm, it is particularly suitable for robust fixation in the thoracic and lumbar spine. Crafted from biocompatible materials like titanium alloy, this screw ensures long-term stability and promotes bone integration. It is commonly used in spinal fusion procedures to correct deformities, stabilize fractures, and manage degenerative conditions.
Offers fixed-angle stability for precise alignment.
Enhances anchorage in the vertebral body, ensuring secure fixation.
Facilitates easy insertion without pre-drilling.
Works seamlessly with connecting rods and other hardware.
Titanium alloy construction ensures durability and biocompatibility.
Reduces friction and promotes osteointegration.
Fixed-angle design ensures rigidity, ideal for deformity correction and trauma cases.
Maintains anatomical integrity, supporting proper spinal biomechanics.
Compatible with a wide range of spinal fixation systems and surgical indications.
Self-tapping design simplifies implantation.
Titanium alloy construction resists mechanical stress and fatigue.
Promotes long-term stability and bone integration.
Stabilizes fractures and dislocations in the thoracic and lumbar regions.
Provides stability during spinal fusion to address disc degeneration.
Prevents vertebral slippage, restoring spinal alignment.
Corrects scoliosis, kyphosis, and other alignment abnormalities.
Stabilizes the spine following the removal of vertebral tumors.
Postoperative infections, though rare, may require additional intervention.
Improper placement or biological factors can lead to screw instability.
Altered biomechanics may accelerate degeneration in adjacent levels.
Precision during insertion is critical to avoid neurovascular injury.
Excessive stress or mechanical issues can compromise fixation.
Development of enhanced materials and minimally invasive implantation techniques.
Rising prevalence of degenerative spine conditions in aging populations.
Growing demand for robust fixation systems following spinal injuries.
Expansion of healthcare infrastructure in developing regions.
Advancements in patient-specific implants and navigation technologies.
The 6.0 monoaxial pedicle screw is a vital component in spinal fixation systems, offering unparalleled stability and precision in treating diverse spinal conditions. Its advanced features and robust performance make it a trusted choice for orthopedic surgeons. As the field of spinal surgery continues to evolve, the 6.0 monoaxial pedicle screw is poised to play a central role in enhancing patient outcomes and advancing surgical techniques.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | REF | Specification | |
6.0 Monoaxial Pedicle Screw | R6ZDD4525 | Ф4.5×25mm | ||
R6ZDD4530 | Ф4.5×30mm | |||
R6ZDD4535 | Ф4.5×35mm | |||
R6ZDD4540 | Ф4.5×40mm | |||
R6ZDD4545 | Ф4.5×45mm | |||
R6ZDD5030 | Ф5.0×30mm | |||
R6ZDD5035 | Ф5.0×35mm | |||
R6ZDD5040 | Ф5.0×40mm | |||
R6ZDD5045 | Ф5.0×45mm | |||
R6ZDD5530 | Ф5.5×30mm | |||
R6ZDD5535 | Ф5.5×35mm | |||
R6ZDD5540 | Ф5.5×40mm | |||
R6ZDD5545 | Ф5.5×45mm | |||
R6ZDD5550 | Ф5.5×50mm | |||
R6ZDD6030 | Ф6.0×30mm | |||
R6ZDD6035 | Ф6.0×35mm | |||
R6ZDD6040 | Ф6.0×40mm | |||
R6ZDD6045 | Ф6.0×45mm | |||
R6ZDD6050 | Ф6.0×50mm | |||
R6ZDD6530 | Ф6.5×30mm | |||
R6ZDD6535 | Ф6.5×35mm | |||
R6ZDD6540 | Ф6.5×40mm | |||
R6ZDD6545 | Ф6.5×45mm | |||
R6ZDD6550 | Ф6.5×50mm | |||
R6ZDD7035 | Ф7.0x35mm | |||
R6ZDD7040 | Ф7.0x40mm | |||
R6ZDD7045 | Ф7.0x45mm | |||
R6ZDD7050 | Ф7.0x50mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 6.0 Monoaxial Pedicle Screw Product Catalog.
2. Choose Your Interested 6.0 Monoaxial Pedicle Screw Product.
3. Ask For A Sample To Test 6.0 Monoaxial Pedicle Screw.
4.Make An Order Of XC Medico's 6.0 Monoaxial Pedicle Screw.
5.Become A Dealer Of XC Medico's 6.0 Monoaxial Pedicle Screw.
1.Better Purchase Prices Of 6.0 Monoaxial Pedicle Screw.
2.100% The Highest Quality 6.0 Monoaxial Pedicle Screw.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 6.0 Monoaxial Pedicle Screw.
6. Quick And Easy Assessment Of XC Medico's 6.0 Monoaxial Pedicle Screw.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 6.0 monoaxial pedicle screw is a cornerstone in spinal fixation systems, renowned for its stability and versatility in treating various spinal pathologies. Designed for precision and durability, this implant plays a critical role in spinal deformity correction, trauma stabilization, and degenerative spine surgeries. This guide provides an in-depth exploration of its features, applications, and future prospects, catering to the needs of orthopedic professionals, medical students, and researchers.
The 6.0 monoaxial pedicle screw is a spinal implant used in posterior fixation systems. "Monoaxial" refers to its rigid, fixed-angle design, providing stable support in a single axis. With a diameter of 6.0 mm, it is particularly suitable for robust fixation in the thoracic and lumbar spine. Crafted from biocompatible materials like titanium alloy, this screw ensures long-term stability and promotes bone integration. It is commonly used in spinal fusion procedures to correct deformities, stabilize fractures, and manage degenerative conditions.
Offers fixed-angle stability for precise alignment.
Enhances anchorage in the vertebral body, ensuring secure fixation.
Facilitates easy insertion without pre-drilling.
Works seamlessly with connecting rods and other hardware.
Titanium alloy construction ensures durability and biocompatibility.
Reduces friction and promotes osteointegration.
Fixed-angle design ensures rigidity, ideal for deformity correction and trauma cases.
Maintains anatomical integrity, supporting proper spinal biomechanics.
Compatible with a wide range of spinal fixation systems and surgical indications.
Self-tapping design simplifies implantation.
Titanium alloy construction resists mechanical stress and fatigue.
Promotes long-term stability and bone integration.
Stabilizes fractures and dislocations in the thoracic and lumbar regions.
Provides stability during spinal fusion to address disc degeneration.
Prevents vertebral slippage, restoring spinal alignment.
Corrects scoliosis, kyphosis, and other alignment abnormalities.
Stabilizes the spine following the removal of vertebral tumors.
Postoperative infections, though rare, may require additional intervention.
Improper placement or biological factors can lead to screw instability.
Altered biomechanics may accelerate degeneration in adjacent levels.
Precision during insertion is critical to avoid neurovascular injury.
Excessive stress or mechanical issues can compromise fixation.
Development of enhanced materials and minimally invasive implantation techniques.
Rising prevalence of degenerative spine conditions in aging populations.
Growing demand for robust fixation systems following spinal injuries.
Expansion of healthcare infrastructure in developing regions.
Advancements in patient-specific implants and navigation technologies.
The 6.0 monoaxial pedicle screw is a vital component in spinal fixation systems, offering unparalleled stability and precision in treating diverse spinal conditions. Its advanced features and robust performance make it a trusted choice for orthopedic surgeons. As the field of spinal surgery continues to evolve, the 6.0 monoaxial pedicle screw is poised to play a central role in enhancing patient outcomes and advancing surgical techniques.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact