RPDJS
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | Ref | Specification | Screw |
Greater Tubercle Locking Plate | RPDJS5HR | 5 H R | HA3.5 HC3.5 | |
RPDJS5HL | 5 H L | HA3.5 HC3.5 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Greater Tubercle Locking Plate Product Catalog.
2. Choose Your Interested Greater Tubercle Locking Plate Product.
3. Ask For A Sample To Test Greater Tubercle Locking Plate.
4.Make An Order Of XC Medico's Greater Tubercle Locking Plate.
5.Become A Dealer Of XC Medico's Greater Tubercle Locking Plate.
1.Better Purchase Prices Of Greater Tubercle Locking Plate.
2.100% The Highest Quality Greater Tubercle Locking Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Greater Tubercle Locking Plate.
6. Quick And Easy Assessment Of XC Medico's Greater Tubercle Locking Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The greater tubercle locking plate is a revolutionary orthopedic device designed for the management of complex shoulder fractures. Specifically utilized for fractures of the proximal humerus, it offers a stable and anatomically precise fixation, significantly improving patient outcomes. In this comprehensive guide, we will delve into the details of the greater tubercle locking plate, covering its features, advantages, disadvantages, and more.
A greater tubercle locking plate is an orthopedic implant specifically engineered for the treatment of greater tubercle fractures, commonly seen in proximal humeral fractures. The device is designed to stabilize the fractured bone fragments by locking screws into the plate, thereby reducing the risk of displacement.
Anatomical design,The plate shape accommodate humerus greater tubercle anatomy,fits close to minimize soft tissue irration.
Bone pins holes are used for bone plates temporary fixation.
Combination locking and compression holes(combi holes),using angular stability or compression according to the requirements.
Locking screws prevent the plate from shifting, providing a more stable fixation.
This plate is particularly beneficial in osteoporotic patients, as it provides a stable construct even in poor-quality bone.
The locking mechanism effectively reduces the risk of fracture displacement during the healing process.
The contoured design helps restore the natural anatomy of the shoulder, which is crucial for optimal range of motion and function.
Where the greater tubercle is pulled away from the humerus by the rotator cuff.
When the greater tubercle and surgical neck are both involved.
Particularly in elderly patients, where bone quality is poor, and stable fixation is challenging.
When the proximal humerus is shattered into multiple pieces, requiring multi-directional screw placement for stability.
As with all surgeries, there is a risk of infection, which can lead to implant failure or prolonged healing.
The proximity of the axillary nerve to the surgical site means there is a risk of nerve injury during plate placement.
The screws or plate may loosen or break, necessitating revision surgery.
Improper plate positioning or scarring can lead to impingement, affecting shoulder movement and causing pain.
In some cases, the bone may fail to heal as expected, requiring further treatment or surgical intervention.
Development of bioresorbable materials may reduce the need for hardware removal surgeries.
Personalized implants based on patient anatomy using 3D printing technology could offer even better anatomical conformity and fixation.
Innovations in minimally invasive surgery are making the implantation of locking plates less traumatic, reducing recovery time and improving cosmetic outcomes.
Future improvements in locking technology aim to increase stability while reducing the risk of hardware failure.
Overall, the greater tubercle locking plate represents a critical development in orthopedic surgery for the management of complex proximal humeral fractures. With continuous innovation, these implants will continue to evolve, offering better patient outcomes and improved surgical techniques.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | Ref | Specification | Screw |
Greater Tubercle Locking Plate | RPDJS5HR | 5 H R | HA3.5 HC3.5 | |
RPDJS5HL | 5 H L | HA3.5 HC3.5 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Greater Tubercle Locking Plate Product Catalog.
2. Choose Your Interested Greater Tubercle Locking Plate Product.
3. Ask For A Sample To Test Greater Tubercle Locking Plate.
4.Make An Order Of XC Medico's Greater Tubercle Locking Plate.
5.Become A Dealer Of XC Medico's Greater Tubercle Locking Plate.
1.Better Purchase Prices Of Greater Tubercle Locking Plate.
2.100% The Highest Quality Greater Tubercle Locking Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Greater Tubercle Locking Plate.
6. Quick And Easy Assessment Of XC Medico's Greater Tubercle Locking Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The greater tubercle locking plate is a revolutionary orthopedic device designed for the management of complex shoulder fractures. Specifically utilized for fractures of the proximal humerus, it offers a stable and anatomically precise fixation, significantly improving patient outcomes. In this comprehensive guide, we will delve into the details of the greater tubercle locking plate, covering its features, advantages, disadvantages, and more.
A greater tubercle locking plate is an orthopedic implant specifically engineered for the treatment of greater tubercle fractures, commonly seen in proximal humeral fractures. The device is designed to stabilize the fractured bone fragments by locking screws into the plate, thereby reducing the risk of displacement.
Anatomical design,The plate shape accommodate humerus greater tubercle anatomy,fits close to minimize soft tissue irration.
Bone pins holes are used for bone plates temporary fixation.
Combination locking and compression holes(combi holes),using angular stability or compression according to the requirements.
Locking screws prevent the plate from shifting, providing a more stable fixation.
This plate is particularly beneficial in osteoporotic patients, as it provides a stable construct even in poor-quality bone.
The locking mechanism effectively reduces the risk of fracture displacement during the healing process.
The contoured design helps restore the natural anatomy of the shoulder, which is crucial for optimal range of motion and function.
Where the greater tubercle is pulled away from the humerus by the rotator cuff.
When the greater tubercle and surgical neck are both involved.
Particularly in elderly patients, where bone quality is poor, and stable fixation is challenging.
When the proximal humerus is shattered into multiple pieces, requiring multi-directional screw placement for stability.
As with all surgeries, there is a risk of infection, which can lead to implant failure or prolonged healing.
The proximity of the axillary nerve to the surgical site means there is a risk of nerve injury during plate placement.
The screws or plate may loosen or break, necessitating revision surgery.
Improper plate positioning or scarring can lead to impingement, affecting shoulder movement and causing pain.
In some cases, the bone may fail to heal as expected, requiring further treatment or surgical intervention.
Development of bioresorbable materials may reduce the need for hardware removal surgeries.
Personalized implants based on patient anatomy using 3D printing technology could offer even better anatomical conformity and fixation.
Innovations in minimally invasive surgery are making the implantation of locking plates less traumatic, reducing recovery time and improving cosmetic outcomes.
Future improvements in locking technology aim to increase stability while reducing the risk of hardware failure.
Overall, the greater tubercle locking plate represents a critical development in orthopedic surgery for the management of complex proximal humeral fractures. With continuous innovation, these implants will continue to evolve, offering better patient outcomes and improved surgical techniques.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact