PRG1LDP
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Pic | Screw | REF. | Spec. |
LC-DCP Humeral Plate | HA3.5 | PRG1LDP4H | 4H | |
PRG1LDP5H | 5H | |||
PRG1LDP6H | 6H | |||
PRG1LDP7H | 7H | |||
PRG1LDP8H | 8H | |||
PRG1LDP9H | 9H | |||
PRG1LDP10H | 10H | |||
PRG1LDP11H | 11H | |||
PRG1LDP12H | 12H |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For LC-DCP Humeral Plate Product Catalog.
2. Choose Your Interested LC-DCP Humeral Plate Product.
3. Ask For A Sample To Test LC-DCP Humeral Plate.
4.Make An Order Of XC Medico's LC-DCP Humeral Plate.
5.Become A Dealer Of XC Medico's LC-DCP Humeral Plate.
1.Better Purchase Prices Of LC-DCP Humeral Plate.
2.100% The Highest Quality LC-DCP Humeral Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient LC-DCP Humeral Plate.
6. Quick And Easy Assessment Of XC Medico's LC-DCP Humeral Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The LC-DCP (Limited Contact Dynamic Compression Plate) Humeral Plate is an advanced orthopedic implant designed to optimize fracture stabilization and promote effective healing in the humerus, the bone of the upper arm. Known for its innovative design and biomechanical benefits, the LC-DCP humeral plate has become a standard in treating complex fractures. This article delves into its features, advantages, applications, risks, and the future of this vital implant.
The LC-DCP Humeral Plate is a metallic implant specifically engineered for the surgical fixation of humeral fractures. The "limited contact" aspect refers to the reduced surface area of the plate that comes into contact with the bone, preserving the periosteal blood supply and minimizing disruption to bone healing. Additionally, the plate facilitates dynamic compression, which enhances interfragmentary stability and fosters proper bone union. Commonly made from biocompatible materials such as titanium or stainless steel, the LC-DCP humeral plate is a cornerstone in modern orthopedic trauma care.
Minimizes interference with periosteal blood supply, promoting biological healing.
Enhances fracture stability by enabling controlled interfragmentary compression.
Pre-contoured to the natural shape of the humerus, reducing the need for intraoperative bending.
Supports locking, cortical, and cancellous screws for a variety of fixation scenarios.
Manufactured from titanium or stainless steel to minimize allergic reactions and ensure durability.
Allow precise placement and visualization under fluoroscopy.
The limited contact design reduces damage to the bone surface, preserving biological integrity.
Suitable for proximal, midshaft, and distal humeral fractures.
Pre-contoured design and flexible screw compatibility simplify surgical procedures.
Promotes faster recovery and reduced complications compared to traditional plates.
Resistant to mechanical stress, ensuring reliable fixation over time.
The low-profile design minimizes discomfort post-surgery.
Provides stable fixation for displaced and comminuted fractures in the upper humerus.
Offers robust stabilization for transverse, oblique, and spiral fractures.
Ensures anatomical alignment in complex intra-articular and extra-articular fractures.
Supports fractures caused by underlying bone conditions such as osteoporosis or metastatic lesions.
Stabilizes multiple fracture sites within the same bone.
A common risk associated with any surgical procedure.
Rare cases of plate or screw loosening, breakage, or migration.
Suboptimal fixation or biological factors may impair fracture healing.
The implant may cause discomfort in some patients, especially those with minimal soft tissue coverage.
Although rare, hypersensitivity to the implant material can occur.
The LC-DCP Humeral Plate market is poised for growth, driven by advancements in material science, surgical techniques, and an increasing prevalence of trauma cases. Emerging technologies such as bioresorbable materials and patient-specific 3D-printed implants are expected to redefine the future of fracture fixation. Moreover, the rising adoption of minimally invasive procedures and increasing healthcare investment in developing regions will further bolster market demand. Innovations focused on improving patient outcomes and reducing complications will continue to enhance the relevance of the LC-DCP Humeral Plate in orthopedic care.
The LC-DCP Humeral Plate represents a significant advancement in orthopedic implant technology, providing effective solutions for humeral fractures with enhanced healing and reduced complications. Its limited contact design, dynamic compression capabilities, and biocompatible materials make it a preferred choice for orthopedic surgeons worldwide. As technology evolves, the LC-DCP Humeral Plate will continue to play a crucial role in trauma management, ensuring better outcomes for patients and driving progress in orthopedic care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Pic | Screw | REF. | Spec. |
LC-DCP Humeral Plate | HA3.5 | PRG1LDP4H | 4H | |
PRG1LDP5H | 5H | |||
PRG1LDP6H | 6H | |||
PRG1LDP7H | 7H | |||
PRG1LDP8H | 8H | |||
PRG1LDP9H | 9H | |||
PRG1LDP10H | 10H | |||
PRG1LDP11H | 11H | |||
PRG1LDP12H | 12H |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For LC-DCP Humeral Plate Product Catalog.
2. Choose Your Interested LC-DCP Humeral Plate Product.
3. Ask For A Sample To Test LC-DCP Humeral Plate.
4.Make An Order Of XC Medico's LC-DCP Humeral Plate.
5.Become A Dealer Of XC Medico's LC-DCP Humeral Plate.
1.Better Purchase Prices Of LC-DCP Humeral Plate.
2.100% The Highest Quality LC-DCP Humeral Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient LC-DCP Humeral Plate.
6. Quick And Easy Assessment Of XC Medico's LC-DCP Humeral Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The LC-DCP (Limited Contact Dynamic Compression Plate) Humeral Plate is an advanced orthopedic implant designed to optimize fracture stabilization and promote effective healing in the humerus, the bone of the upper arm. Known for its innovative design and biomechanical benefits, the LC-DCP humeral plate has become a standard in treating complex fractures. This article delves into its features, advantages, applications, risks, and the future of this vital implant.
The LC-DCP Humeral Plate is a metallic implant specifically engineered for the surgical fixation of humeral fractures. The "limited contact" aspect refers to the reduced surface area of the plate that comes into contact with the bone, preserving the periosteal blood supply and minimizing disruption to bone healing. Additionally, the plate facilitates dynamic compression, which enhances interfragmentary stability and fosters proper bone union. Commonly made from biocompatible materials such as titanium or stainless steel, the LC-DCP humeral plate is a cornerstone in modern orthopedic trauma care.
Minimizes interference with periosteal blood supply, promoting biological healing.
Enhances fracture stability by enabling controlled interfragmentary compression.
Pre-contoured to the natural shape of the humerus, reducing the need for intraoperative bending.
Supports locking, cortical, and cancellous screws for a variety of fixation scenarios.
Manufactured from titanium or stainless steel to minimize allergic reactions and ensure durability.
Allow precise placement and visualization under fluoroscopy.
The limited contact design reduces damage to the bone surface, preserving biological integrity.
Suitable for proximal, midshaft, and distal humeral fractures.
Pre-contoured design and flexible screw compatibility simplify surgical procedures.
Promotes faster recovery and reduced complications compared to traditional plates.
Resistant to mechanical stress, ensuring reliable fixation over time.
The low-profile design minimizes discomfort post-surgery.
Provides stable fixation for displaced and comminuted fractures in the upper humerus.
Offers robust stabilization for transverse, oblique, and spiral fractures.
Ensures anatomical alignment in complex intra-articular and extra-articular fractures.
Supports fractures caused by underlying bone conditions such as osteoporosis or metastatic lesions.
Stabilizes multiple fracture sites within the same bone.
A common risk associated with any surgical procedure.
Rare cases of plate or screw loosening, breakage, or migration.
Suboptimal fixation or biological factors may impair fracture healing.
The implant may cause discomfort in some patients, especially those with minimal soft tissue coverage.
Although rare, hypersensitivity to the implant material can occur.
The LC-DCP Humeral Plate market is poised for growth, driven by advancements in material science, surgical techniques, and an increasing prevalence of trauma cases. Emerging technologies such as bioresorbable materials and patient-specific 3D-printed implants are expected to redefine the future of fracture fixation. Moreover, the rising adoption of minimally invasive procedures and increasing healthcare investment in developing regions will further bolster market demand. Innovations focused on improving patient outcomes and reducing complications will continue to enhance the relevance of the LC-DCP Humeral Plate in orthopedic care.
The LC-DCP Humeral Plate represents a significant advancement in orthopedic implant technology, providing effective solutions for humeral fractures with enhanced healing and reduced complications. Its limited contact design, dynamic compression capabilities, and biocompatible materials make it a preferred choice for orthopedic surgeons worldwide. As technology evolves, the LC-DCP Humeral Plate will continue to play a crucial role in trauma management, ensuring better outcomes for patients and driving progress in orthopedic care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact