XN-Revision Femoral Condylar | ||||
Code | Size | Description | Material | ![]() |
5270-01021 | 2L# | width 60.5mm | CoCrMo | |
5270-01022 | 2R# | width 60.5mm | ||
5270-01031 | 3L# | width 63mm | ||
5270-01032 | 3R# | width 63mm | ||
5270-01041 | 4L# | width 65mm | ||
5270-01042 | 4R# | width 65mm | ||
5270-01051 | 5L# | width 67.5mm | ||
5270-01052 | 5R# | width 67.5mm | ||
5270-01061 | 6L# | width 70.5mm | ||
5270-01062 | 6R# | width 70.5mm | ||
5270-01071 | 7L# | width 75mm | ||
5270-01072 | 7R# | width 75mm | ||
XN-(R-CCK/PSP) Fully / Semi Constrained Insert | ||||
Code | Size | Description | Material | ![]() |
5271-09031 | 2/3/4# | H 9mm, W 68mm | UHMWPE / HXLPE /VE-HXL | |
5271-11031 | H 11mm, W 68mm | |||
5271-13031 | H 13mm, W 68mm | |||
5271-15031 | H 15mm, W 68mm | |||
5271-17031 | H 17mm, W 68mm | |||
5271-19031 | H 19mm, W 68mm | |||
5271-09051 | 5/6# | H 9mm, W 75mm | ||
5271-11051 | H 11mm, W 75mm | |||
5271-13051 | H 13mm, W 75mm | |||
5271-15051 | H 15mm, W 75mm | |||
5271-17051 | H 17mm, W 75mm | |||
5271-19051 | H 19mm, W 75mm | |||
5271-09071 | 7# | H 9mm, W 84mm | ||
5271-11071 | H 11mm, W 84mm | |||
5271-13071 | H 13mm, W 84mm | |||
5271-15071 | H 15mm, W 84mm | |||
5271-17071 | H 17mm, W 84mm | |||
5271-19071 | H 19mm, W 84mm | |||
XN-Revision Tibial Tray (compatible with primary system) | ||||
Code | Size | Material | ![]() | |
5171-01020 | Tibial tray(CLJMC) 2#, width 61mm | CoCrMo | ||
5171-01030 | Tibial tray(CLJMC) 3#, width 65mm | |||
5171-01040 | Tibial tray(CLJMC) 4#, width 68mm | |||
5171-01050 | Tibial tray(CLJMC) 5#, width 70mm | |||
5171-01060 | Tibial tray(CLJMC) 6#, width 75mm | |||
5171-01070 | Tibial tray(CLJMC) 7#, width 79mm | |||
Straight Femoral/Tibial Universal Extension Stem (ST) | ||||
Code | Size | Material | ![]() | |
5273-09060 | Diameter 9mm, Length 60mm | Ti6Al4V | ||
5273-10060 | Diameter 10mm, Length 60mm | |||
5273-11060 | Diameter 11mm, Length 60mm | |||
5273-12060 | Diameter 12mm, Length 60mm | |||
5273-13060 | Diameter 13mm, Length 60mm | |||
5273-14060 | Diameter 14mm, Length 60mm | |||
5273-15060 | Diameter 15mm, Length 60mm | |||
5273-16060 | Diameter 16mm, Length 60mm | |||
5273-09100 | Diameter 9mm, Length 100mm | |||
5273-10100 | Diameter 10mm, Length 100mm | |||
5273-11100 | Diameter 11mm, Length 100mm | |||
5273-12100 | Diameter 12mm, Length 100mm | |||
5273-13100 | Diameter 13mm, Length 100mm | |||
5273-14100 | Diameter 14mm, Length 100mm | |||
5273-15100 | Diameter 15mm, Length 100mm | |||
5273-16100 | Diameter 16mm, Length 100mm | |||
5273-09130 | Diameter 9mm, Length 130mm | |||
5273-10130 | Diameter 10mm, Length 130mm | |||
5273-11130 | Diameter 11mm, Length 130mm | |||
5273-12130 | Diameter 12mm, Length 130mm | |||
5273-13130 | Diameter 13mm, Length 130mm | |||
5273-14130 | Diameter 14mm, Length 130mm | |||
5273-15130 | Diameter 15mm, Length 130mm | |||
5273-16130 | Diameter 16mm, Length 130mm | |||
Offset Femoral/Tibial Universal Extension Stem (OT) | ||||
Code | Size | Material | ![]() | |
5273-09103 | Diameter 9mm, Length 100mm | Ti6Al4V | ||
5273-10103 | Diameter 10mm, Length 100mm | |||
5273-11103 | Diameter 11mm, Length 100mm | |||
5273-12103 | Diameter 12mm, Length 100mm | |||
5273-13103 | Diameter 13mm, Length 100mm | |||
5273-14103 | Diameter 14mm, Length 100mm | |||
5273-15103 | Diameter 15mm, Length 100mm | |||
5273-16103 | Diameter 16mm, Length 100mm | |||
5273-09133 | Diameter 9mm, Length 130mm | |||
5273-10133 | Diameter 10mm, Length 130mm | |||
5273-11133 | Diameter 11mm, Length 130mm | |||
5273-12133 | Diameter 12mm, Length 130mm | |||
5273-13133 | Diameter 13mm, Length 130mm | |||
5273-14133 | Diameter 14mm, Length 130mm | |||
5273-15133 | Diameter 15mm, Length 130mm | |||
5273-16133 | Diameter 16mm, Length 130mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Revision Total Knee Product Catalog.
2. Choose Your Interested Revision Total Knee Product.
3. Ask For A Sample To Test Revision Total Knee.
4.Make An Order Of XC Medico's Revision Total Knee.
5.Become A Dealer Of XC Medico's Revision Total Knee.
1.Better Purchase Prices Of Revision Total Knee.
2.100% The Highest Quality Revision Total Knee.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Revision Total Knee.
6. Quick And Easy Assessment Of XC Medico's Revision Total Knee.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Revision Total Knee Replacement is a critical procedure in orthopedic care, addressing the needs of patients who experience complications or failures following primary knee replacement surgery. This guide provides a detailed exploration of Revision Total Knee Replacement, including its features, benefits, applications, risks, and future market trends.
Revision Total Knee Replacement refers to a secondary surgical procedure performed to replace or repair a failed or problematic primary knee prosthesis. It is typically indicated for patients who develop issues such as implant loosening, infection, wear, or misalignment after their initial knee replacement. The objective of revision surgery is to restore joint function, alleviate pain, and address any complications from the primary procedure.
Allows for customization to address bone loss, alignment issues, and soft tissue balancing.
Constructed from high-quality materials such as cobalt-chromium alloys, titanium, and advanced polyethylene to withstand the increased demands of revision surgery.
Incorporates stems, augments, and constrained components to provide additional support and stability.
Includes cemented and cementless fixation methods to accommodate varying bone qualities.
Designed to mimic natural knee movement while minimizing wear and tear.
Specialized tools and techniques ensure accurate implantation and alignment.
Effectively addresses pain caused by implant failure or complications.
Enables patients to regain mobility and perform daily activities.
Addresses bone loss and soft tissue deficiencies for reliable joint stability.
Incorporates advanced materials and designs to enhance the durability of the revision implant.
Modular designs and precise instrumentation enhance the success of complex revision surgeries.
Suitable for addressing a wide range of complications and patient-specific needs.
Fractures occurring around a previous knee implant often require revision surgery for stabilization.
Cases involving extensive bone loss due to osteolysis or trauma can be addressed with augment-supported revision implants.
Instances where prior fracture fixation has failed may necessitate revision knee replacement.
Revision implants provide robust solutions for fractures that compromise joint integrity.
Revision surgeries have a higher risk of infection compared to primary procedures.
Although designed for durability, revision implants may loosen over time.
Deep vein thrombosis (DVT) and pulmonary embolism are possible postoperative complications.
Rare but serious injuries to surrounding structures may occur during surgery.
Recovery from revision surgery may take longer due to its complexity.
Some patients may experience residual discomfort or limited motion.
Innovations in implant design, materials, and surgical techniques continue to improve outcomes.
Robotics enhances precision, particularly in complex revision cases.
3D printing and imaging technologies enable the creation of patient-specific implants for better fit and performance.
Increasing access to advanced healthcare in emerging markets fuels growth.
Research into materials and designs aims to extend implant lifespan and reduce the need for further revisions.
Revision Total Knee Replacement is a vital solution for addressing complications and failures associated with primary knee replacements. With features such as modular designs, durable materials, and advanced surgical tools, it ensures improved outcomes for complex cases. Although associated with risks, the benefits of pain relief, restored functionality, and enhanced stability make it a cornerstone of modern orthopedic care. As technology and market dynamics evolve, the future of Revision Total Knee Replacement promises greater innovation and improved patient outcomes.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
XN-Revision Femoral Condylar | ||||
Code | Size | Description | Material | ![]() |
5270-01021 | 2L# | width 60.5mm | CoCrMo | |
5270-01022 | 2R# | width 60.5mm | ||
5270-01031 | 3L# | width 63mm | ||
5270-01032 | 3R# | width 63mm | ||
5270-01041 | 4L# | width 65mm | ||
5270-01042 | 4R# | width 65mm | ||
5270-01051 | 5L# | width 67.5mm | ||
5270-01052 | 5R# | width 67.5mm | ||
5270-01061 | 6L# | width 70.5mm | ||
5270-01062 | 6R# | width 70.5mm | ||
5270-01071 | 7L# | width 75mm | ||
5270-01072 | 7R# | width 75mm | ||
XN-(R-CCK/PSP) Fully / Semi Constrained Insert | ||||
Code | Size | Description | Material | ![]() |
5271-09031 | 2/3/4# | H 9mm, W 68mm | UHMWPE / HXLPE /VE-HXL | |
5271-11031 | H 11mm, W 68mm | |||
5271-13031 | H 13mm, W 68mm | |||
5271-15031 | H 15mm, W 68mm | |||
5271-17031 | H 17mm, W 68mm | |||
5271-19031 | H 19mm, W 68mm | |||
5271-09051 | 5/6# | H 9mm, W 75mm | ||
5271-11051 | H 11mm, W 75mm | |||
5271-13051 | H 13mm, W 75mm | |||
5271-15051 | H 15mm, W 75mm | |||
5271-17051 | H 17mm, W 75mm | |||
5271-19051 | H 19mm, W 75mm | |||
5271-09071 | 7# | H 9mm, W 84mm | ||
5271-11071 | H 11mm, W 84mm | |||
5271-13071 | H 13mm, W 84mm | |||
5271-15071 | H 15mm, W 84mm | |||
5271-17071 | H 17mm, W 84mm | |||
5271-19071 | H 19mm, W 84mm | |||
XN-Revision Tibial Tray (compatible with primary system) | ||||
Code | Size | Material | ![]() | |
5171-01020 | Tibial tray(CLJMC) 2#, width 61mm | CoCrMo | ||
5171-01030 | Tibial tray(CLJMC) 3#, width 65mm | |||
5171-01040 | Tibial tray(CLJMC) 4#, width 68mm | |||
5171-01050 | Tibial tray(CLJMC) 5#, width 70mm | |||
5171-01060 | Tibial tray(CLJMC) 6#, width 75mm | |||
5171-01070 | Tibial tray(CLJMC) 7#, width 79mm | |||
Straight Femoral/Tibial Universal Extension Stem (ST) | ||||
Code | Size | Material | ![]() | |
5273-09060 | Diameter 9mm, Length 60mm | Ti6Al4V | ||
5273-10060 | Diameter 10mm, Length 60mm | |||
5273-11060 | Diameter 11mm, Length 60mm | |||
5273-12060 | Diameter 12mm, Length 60mm | |||
5273-13060 | Diameter 13mm, Length 60mm | |||
5273-14060 | Diameter 14mm, Length 60mm | |||
5273-15060 | Diameter 15mm, Length 60mm | |||
5273-16060 | Diameter 16mm, Length 60mm | |||
5273-09100 | Diameter 9mm, Length 100mm | |||
5273-10100 | Diameter 10mm, Length 100mm | |||
5273-11100 | Diameter 11mm, Length 100mm | |||
5273-12100 | Diameter 12mm, Length 100mm | |||
5273-13100 | Diameter 13mm, Length 100mm | |||
5273-14100 | Diameter 14mm, Length 100mm | |||
5273-15100 | Diameter 15mm, Length 100mm | |||
5273-16100 | Diameter 16mm, Length 100mm | |||
5273-09130 | Diameter 9mm, Length 130mm | |||
5273-10130 | Diameter 10mm, Length 130mm | |||
5273-11130 | Diameter 11mm, Length 130mm | |||
5273-12130 | Diameter 12mm, Length 130mm | |||
5273-13130 | Diameter 13mm, Length 130mm | |||
5273-14130 | Diameter 14mm, Length 130mm | |||
5273-15130 | Diameter 15mm, Length 130mm | |||
5273-16130 | Diameter 16mm, Length 130mm | |||
Offset Femoral/Tibial Universal Extension Stem (OT) | ||||
Code | Size | Material | ![]() | |
5273-09103 | Diameter 9mm, Length 100mm | Ti6Al4V | ||
5273-10103 | Diameter 10mm, Length 100mm | |||
5273-11103 | Diameter 11mm, Length 100mm | |||
5273-12103 | Diameter 12mm, Length 100mm | |||
5273-13103 | Diameter 13mm, Length 100mm | |||
5273-14103 | Diameter 14mm, Length 100mm | |||
5273-15103 | Diameter 15mm, Length 100mm | |||
5273-16103 | Diameter 16mm, Length 100mm | |||
5273-09133 | Diameter 9mm, Length 130mm | |||
5273-10133 | Diameter 10mm, Length 130mm | |||
5273-11133 | Diameter 11mm, Length 130mm | |||
5273-12133 | Diameter 12mm, Length 130mm | |||
5273-13133 | Diameter 13mm, Length 130mm | |||
5273-14133 | Diameter 14mm, Length 130mm | |||
5273-15133 | Diameter 15mm, Length 130mm | |||
5273-16133 | Diameter 16mm, Length 130mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Revision Total Knee Product Catalog.
2. Choose Your Interested Revision Total Knee Product.
3. Ask For A Sample To Test Revision Total Knee.
4.Make An Order Of XC Medico's Revision Total Knee.
5.Become A Dealer Of XC Medico's Revision Total Knee.
1.Better Purchase Prices Of Revision Total Knee.
2.100% The Highest Quality Revision Total Knee.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Revision Total Knee.
6. Quick And Easy Assessment Of XC Medico's Revision Total Knee.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Revision Total Knee Replacement is a critical procedure in orthopedic care, addressing the needs of patients who experience complications or failures following primary knee replacement surgery. This guide provides a detailed exploration of Revision Total Knee Replacement, including its features, benefits, applications, risks, and future market trends.
Revision Total Knee Replacement refers to a secondary surgical procedure performed to replace or repair a failed or problematic primary knee prosthesis. It is typically indicated for patients who develop issues such as implant loosening, infection, wear, or misalignment after their initial knee replacement. The objective of revision surgery is to restore joint function, alleviate pain, and address any complications from the primary procedure.
Allows for customization to address bone loss, alignment issues, and soft tissue balancing.
Constructed from high-quality materials such as cobalt-chromium alloys, titanium, and advanced polyethylene to withstand the increased demands of revision surgery.
Incorporates stems, augments, and constrained components to provide additional support and stability.
Includes cemented and cementless fixation methods to accommodate varying bone qualities.
Designed to mimic natural knee movement while minimizing wear and tear.
Specialized tools and techniques ensure accurate implantation and alignment.
Effectively addresses pain caused by implant failure or complications.
Enables patients to regain mobility and perform daily activities.
Addresses bone loss and soft tissue deficiencies for reliable joint stability.
Incorporates advanced materials and designs to enhance the durability of the revision implant.
Modular designs and precise instrumentation enhance the success of complex revision surgeries.
Suitable for addressing a wide range of complications and patient-specific needs.
Fractures occurring around a previous knee implant often require revision surgery for stabilization.
Cases involving extensive bone loss due to osteolysis or trauma can be addressed with augment-supported revision implants.
Instances where prior fracture fixation has failed may necessitate revision knee replacement.
Revision implants provide robust solutions for fractures that compromise joint integrity.
Revision surgeries have a higher risk of infection compared to primary procedures.
Although designed for durability, revision implants may loosen over time.
Deep vein thrombosis (DVT) and pulmonary embolism are possible postoperative complications.
Rare but serious injuries to surrounding structures may occur during surgery.
Recovery from revision surgery may take longer due to its complexity.
Some patients may experience residual discomfort or limited motion.
Innovations in implant design, materials, and surgical techniques continue to improve outcomes.
Robotics enhances precision, particularly in complex revision cases.
3D printing and imaging technologies enable the creation of patient-specific implants for better fit and performance.
Increasing access to advanced healthcare in emerging markets fuels growth.
Research into materials and designs aims to extend implant lifespan and reduce the need for further revisions.
Revision Total Knee Replacement is a vital solution for addressing complications and failures associated with primary knee replacements. With features such as modular designs, durable materials, and advanced surgical tools, it ensures improved outcomes for complex cases. Although associated with risks, the benefits of pain relief, restored functionality, and enhanced stability make it a cornerstone of modern orthopedic care. As technology and market dynamics evolve, the future of Revision Total Knee Replacement promises greater innovation and improved patient outcomes.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
content is empty!
Contact