RP1H
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
1.5 Maxillofacial Micro Arc Plate | RP1H623H1 | 6Holes,23mm | |
RP1H830H1 | 8Holes,30mm | ||
RP1H1037H1 | 10Holes,37mm | ||
RP1H1243H1 | 12Holes,43mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Maxillofacial Micro Arc Plate Product Catalog.
2. Choose Your Interested 1.5 Maxillofacial Micro Arc Plate Product.
3. Ask For A Sample To Test 1.5 Maxillofacial Micro Arc Plate.
4.Make An Order Of XC Medico's 1.5 Maxillofacial Micro Arc Plate.
5.Become A Dealer Of XC Medico's 1.5 Maxillofacial Micro Arc Plate.
1.Better Purchase Prices Of 1.5 Maxillofacial Micro Arc Plate.
2.100% The Highest Quality 1.5 Maxillofacial Micro Arc Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Maxillofacial Micro Arc Plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Maxillofacial Micro Arc Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 1.5 Maxillofacial Micro Arc Plate is an advanced orthopedic implant used in the repair of fractures in the maxillofacial region. Characterized by its micro-thickness and curved design, this plate is specifically designed to offer precise, stable fixation for fractures of the facial bones, including the mandible, maxilla, and zygomatic arch. With its application primarily in trauma cases and reconstructive surgeries, the 1.5 Maxillofacial Micro Arc Plate provides a blend of strength, flexibility, and minimal invasiveness. This comprehensive guide aims to explore the features, advantages, risks, and future market outlook of the 1.5 Maxillofacial Micro Arc Plate, focusing on its role in modern maxillofacial surgery.
The 1.5 Maxillofacial Micro Arc Plate is a titanium or stainless steel implant designed for the stabilization and fixation of facial bone fractures. The "1.5" refers to the plate's thickness (1.5 mm), which strikes an ideal balance between strength and minimal invasiveness. The "arc" design refers to the curved shape of the plate, which is typically used for fractures in areas like the zygomatic arch or the orbital rim, where the natural curvature of the bone needs to be restored. This plate is commonly used in both traumatic injuries and elective reconstructive surgeries, offering a secure and stable method to align fractured bones during the healing process.
At just 1.5 mm thick, the plate offers a low profile that minimizes soft tissue damage and provides a more aesthetic outcome with less visible scarring.
The curved design allows the plate to follow the natural contours of the facial bones, especially in regions like the zygomatic arch and orbital rim, ensuring a snug fit and stable fixation.
Made from high-strength titanium or stainless steel, the plate offers excellent strength-to-weight ratio, biocompatibility, and resistance to corrosion. These properties reduce the risk of rejection and ensure long-term stability.
The plate features multiple screw holes along its length, allowing for flexible screw placement and optimal alignment of fractured bone fragments.
The plate can be easily contoured to match the unique anatomical structure of each patient’s facial bones, providing a customized fit for better stability and recovery.
Its small size and low profile allow for minimally invasive procedures, which reduce tissue trauma, minimize scarring, and shorten recovery times.
The plate's curved design helps restore the natural shape and function of the facial bones, which is essential for preserving facial aesthetics after trauma.
Despite its thin profile, the plate provides excellent mechanical strength, ensuring stable fixation of fractured bone segments during the healing process.
By providing stable support, the plate allows for early functional rehabilitation, such as jaw movement, which can reduce the risk of complications like joint stiffness or muscle atrophy.
Made from titanium or stainless steel, the materials used in the plate are highly biocompatible, reducing the risk of infection and rejection.
The arc-shaped design of the plate is ideal for stabilizing fractures in the zygomatic arch, where precise alignment of the bone is critical for both functional and cosmetic outcomes.
The plate's curvature makes it well-suited for stabilizing fractures in the orbital rim and floor, areas that are crucial for eye function and facial symmetry.
In some cases, the plate can be used to stabilize fractures of the maxilla, especially when the fractures involve the upper jaw or the area around the nose and cheekbones.
While less common, the plate can be used for certain mandibular fractures, particularly in the areas of the body and angle of the mandible.
For more complex fractures involving the midface, the 1.5 Maxillofacial Micro Arc Plate can provide stable fixation, particularly in the upper facial skeleton.
The introduction of a foreign object into the body always carries a risk of infection, especially if aseptic techniques are not followed during surgery.
In some cases, the plate may become exposed through the skin due to poor healing or tension on the incision site. This may require additional surgery to reposition or remove the plate.
The facial region contains several important nerves, including the facial nerve, and improper placement of the plate could result in nerve damage, leading to sensory or motor deficits.
In some cases, the fracture may not heal properly (nonunion), or the bones may heal incorrectly (malunion), which may require further intervention.
Though rare, some patients may develop an allergic reaction to the metal components of the plate, particularly if they have a sensitivity to titanium or stainless steel.
As medical technology continues to evolve, future versions of the plate may feature improved materials, such as bioresorbable metals or alloys, which can eliminate the need for secondary surgery to remove the implant.
The rising incidence of facial fractures due to accidents, sports injuries, and violence is likely to drive the demand for effective fracture fixation devices like the 1.5 Maxillofacial Micro Arc Plate.
As cosmetic surgery and facial reconstruction procedures become more popular, the demand for precise, minimally invasive implants will continue to rise.
The global aging population, which is more prone to bone fractures, including facial fractures, will contribute to the expanding market for maxillofacial implants.
The 1.5 Maxillofacial Micro Arc Plate is a cutting-edge implant designed for the stabilization and repair of fractures in the facial bones. Its small size, curved design, and biocompatible materials make it an excellent choice for surgeons looking to restore both the function and aesthetics of the face after trauma or surgery. With the ability to treat various types of fractures, including those in the zygomatic arch, orbit, and maxilla, this plate provides superior stability while minimizing invasiveness. While risks such as infection and nerve injury exist, proper surgical planning and technique can mitigate these complications. The future market for the 1.5 Maxillofacial Micro Arc Plate is promising, driven by technological advancements and the increasing demand for both trauma and cosmetic facial surgeries. Ultimately, this implant is a vital component of modern maxillofacial surgery, offering both medical and aesthetic benefits to patients worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
1.5 Maxillofacial Micro Arc Plate | RP1H623H1 | 6Holes,23mm | |
RP1H830H1 | 8Holes,30mm | ||
RP1H1037H1 | 10Holes,37mm | ||
RP1H1243H1 | 12Holes,43mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 1.5 Maxillofacial Micro Arc Plate Product Catalog.
2. Choose Your Interested 1.5 Maxillofacial Micro Arc Plate Product.
3. Ask For A Sample To Test 1.5 Maxillofacial Micro Arc Plate.
4.Make An Order Of XC Medico's 1.5 Maxillofacial Micro Arc Plate.
5.Become A Dealer Of XC Medico's 1.5 Maxillofacial Micro Arc Plate.
1.Better Purchase Prices Of 1.5 Maxillofacial Micro Arc Plate.
2.100% The Highest Quality 1.5 Maxillofacial Micro Arc Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 1.5 Maxillofacial Micro Arc Plate.
6. Quick And Easy Assessment Of XC Medico's 1.5 Maxillofacial Micro Arc Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 1.5 Maxillofacial Micro Arc Plate is an advanced orthopedic implant used in the repair of fractures in the maxillofacial region. Characterized by its micro-thickness and curved design, this plate is specifically designed to offer precise, stable fixation for fractures of the facial bones, including the mandible, maxilla, and zygomatic arch. With its application primarily in trauma cases and reconstructive surgeries, the 1.5 Maxillofacial Micro Arc Plate provides a blend of strength, flexibility, and minimal invasiveness. This comprehensive guide aims to explore the features, advantages, risks, and future market outlook of the 1.5 Maxillofacial Micro Arc Plate, focusing on its role in modern maxillofacial surgery.
The 1.5 Maxillofacial Micro Arc Plate is a titanium or stainless steel implant designed for the stabilization and fixation of facial bone fractures. The "1.5" refers to the plate's thickness (1.5 mm), which strikes an ideal balance between strength and minimal invasiveness. The "arc" design refers to the curved shape of the plate, which is typically used for fractures in areas like the zygomatic arch or the orbital rim, where the natural curvature of the bone needs to be restored. This plate is commonly used in both traumatic injuries and elective reconstructive surgeries, offering a secure and stable method to align fractured bones during the healing process.
At just 1.5 mm thick, the plate offers a low profile that minimizes soft tissue damage and provides a more aesthetic outcome with less visible scarring.
The curved design allows the plate to follow the natural contours of the facial bones, especially in regions like the zygomatic arch and orbital rim, ensuring a snug fit and stable fixation.
Made from high-strength titanium or stainless steel, the plate offers excellent strength-to-weight ratio, biocompatibility, and resistance to corrosion. These properties reduce the risk of rejection and ensure long-term stability.
The plate features multiple screw holes along its length, allowing for flexible screw placement and optimal alignment of fractured bone fragments.
The plate can be easily contoured to match the unique anatomical structure of each patient’s facial bones, providing a customized fit for better stability and recovery.
Its small size and low profile allow for minimally invasive procedures, which reduce tissue trauma, minimize scarring, and shorten recovery times.
The plate's curved design helps restore the natural shape and function of the facial bones, which is essential for preserving facial aesthetics after trauma.
Despite its thin profile, the plate provides excellent mechanical strength, ensuring stable fixation of fractured bone segments during the healing process.
By providing stable support, the plate allows for early functional rehabilitation, such as jaw movement, which can reduce the risk of complications like joint stiffness or muscle atrophy.
Made from titanium or stainless steel, the materials used in the plate are highly biocompatible, reducing the risk of infection and rejection.
The arc-shaped design of the plate is ideal for stabilizing fractures in the zygomatic arch, where precise alignment of the bone is critical for both functional and cosmetic outcomes.
The plate's curvature makes it well-suited for stabilizing fractures in the orbital rim and floor, areas that are crucial for eye function and facial symmetry.
In some cases, the plate can be used to stabilize fractures of the maxilla, especially when the fractures involve the upper jaw or the area around the nose and cheekbones.
While less common, the plate can be used for certain mandibular fractures, particularly in the areas of the body and angle of the mandible.
For more complex fractures involving the midface, the 1.5 Maxillofacial Micro Arc Plate can provide stable fixation, particularly in the upper facial skeleton.
The introduction of a foreign object into the body always carries a risk of infection, especially if aseptic techniques are not followed during surgery.
In some cases, the plate may become exposed through the skin due to poor healing or tension on the incision site. This may require additional surgery to reposition or remove the plate.
The facial region contains several important nerves, including the facial nerve, and improper placement of the plate could result in nerve damage, leading to sensory or motor deficits.
In some cases, the fracture may not heal properly (nonunion), or the bones may heal incorrectly (malunion), which may require further intervention.
Though rare, some patients may develop an allergic reaction to the metal components of the plate, particularly if they have a sensitivity to titanium or stainless steel.
As medical technology continues to evolve, future versions of the plate may feature improved materials, such as bioresorbable metals or alloys, which can eliminate the need for secondary surgery to remove the implant.
The rising incidence of facial fractures due to accidents, sports injuries, and violence is likely to drive the demand for effective fracture fixation devices like the 1.5 Maxillofacial Micro Arc Plate.
As cosmetic surgery and facial reconstruction procedures become more popular, the demand for precise, minimally invasive implants will continue to rise.
The global aging population, which is more prone to bone fractures, including facial fractures, will contribute to the expanding market for maxillofacial implants.
The 1.5 Maxillofacial Micro Arc Plate is a cutting-edge implant designed for the stabilization and repair of fractures in the facial bones. Its small size, curved design, and biocompatible materials make it an excellent choice for surgeons looking to restore both the function and aesthetics of the face after trauma or surgery. With the ability to treat various types of fractures, including those in the zygomatic arch, orbit, and maxilla, this plate provides superior stability while minimizing invasiveness. While risks such as infection and nerve injury exist, proper surgical planning and technique can mitigate these complications. The future market for the 1.5 Maxillofacial Micro Arc Plate is promising, driven by technological advancements and the increasing demand for both trauma and cosmetic facial surgeries. Ultimately, this implant is a vital component of modern maxillofacial surgery, offering both medical and aesthetic benefits to patients worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact