RP2H
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini 90°L-Plate | RP2H419L2L | 4 holes, 0.8mm, 19mm, Left | |
RP2H419L2R | 4 holes, 0.8mm, 19mm, Right | ||
RP2H423L2L | 4 holes, 0.8mm, 23mm, Left | ||
RP2H423L2R | 4 holes, 0.8mm, 23mm, Right |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini 90°L-Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini 90°L-Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini 90°L-Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini 90°L-Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini 90°L-Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini 90°L-Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini 90°L-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini 90°L-Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini 90°L-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini 90°L-Plate is an innovative orthopedic implant designed specifically for the delicate structures of the maxillofacial region. This plate is widely used in reconstructive surgeries, particularly in the treatment of fractures involving the zygoma, mandible, and orbital bones. Its design enables precise and secure fixation, offering both functional and aesthetic benefits. This comprehensive guide explores the features, advantages, clinical applications, potential risks, and the future market of this implant.
The 2.0 Maxillofacial Mini 90°L-Plate is a small, specialized implant used in maxillofacial surgery to stabilize fractures in the facial skeleton. It is typically made from biocompatible materials such as titanium or stainless steel, which are both strong and lightweight. The "90°" refers to the angle between the arms of the "L"-shaped plate, which is designed to provide enhanced mechanical stability and precise alignment during fracture fixation.
This plate is used in procedures requiring small and delicate plates for the reconstruction of facial fractures, including those of the mandible, zygomatic arch, and orbital rim. Its small size makes it ideal for minimally invasive surgeries, providing reduced trauma to surrounding tissues.
The L-Plate's unique design, with a 90° angle between the two arms, ensures optimal stabilization of fractures requiring angular support. This design enhances fixation, especially in fractures involving complex geometries.
The plate is compact, making it suitable for use in small, intricate areas of the face. Its small profile allows for minimal surgical access, promoting quicker recovery and less scarring.
This plate can be used with locking screws, which provide superior fixation compared to traditional plates, ensuring that the bone fragments remain securely aligned during the healing process.
The plate is often pre-contoured to closely match the natural contours of the maxillofacial bones. This reduces the need for extensive adjustments during surgery.
Made from medical-grade titanium or stainless steel, the plate is both strong and lightweight. Titanium, in particular, is favored for its resistance to corrosion and its biocompatibility, ensuring that the body will accept the implant with minimal adverse reactions.
The 90° design and locking screws provide rigid fixation, significantly reducing the chances of malunion or non-union. This ensures that the bone fragments are held in place during the healing process, leading to better outcomes.
Due to its small size and pre-contoured shape, the plate facilitates minimally invasive surgical techniques. This reduces soft tissue damage, leading to quicker recovery, less post-operative pain, and smaller scars.
The stability and rigidity provided by the locking mechanism allow for faster bone healing. With proper stabilization, patients often experience reduced swelling and faster functional recovery.
The plate's precision and adaptability to the anatomy of the maxillofacial region help minimize complications, such as plate migration, screw loosening, or infection.
The plate can be applied to a variety of maxillofacial fractures, including those in the mandible, zygomatic arch, and orbital rim, making it a versatile tool in the reconstructive surgeon's arsenal.
The plate is commonly used in the treatment of fractures to the zygomatic arch or malar bones. Its design helps in restoring the facial contour and ensuring proper alignment.
The plate is highly effective in stabilizing fractures of the mandibular body or ramus, providing support for the bony structures that are crucial for chewing and speaking.
The plate is also used in treating fractures of the orbital rim, a common site for trauma. Its rigid fixation helps restore the anatomical structure of the eye socket and prevents further injury to the eye or optic nerve.
In cases of Le Fort I, II, and III fractures, the plate helps to stabilize the maxilla and mid-face, ensuring the correct alignment of the facial bones during the healing process.
The mini L-Plate is often used in post-traumatic reconstruction of the facial skeleton,helping to restore both function and aesthetic appearance.
As with any surgical procedure involving implants, there is a risk of infection at the incision or around the implant site. Strict sterile techniques must be followed to minimize this risk.
Due to the proximity of the facial nerves, there is a risk of nerve damage during surgery. This can lead to temporary or permanent sensory or motor deficits, such as numbness or paralysis of facial muscles.
While the plate is designed for durability, it can still fail due to factors such as inadequate screw fixation, trauma during recovery, or excessive mechanical stress on the plate.
If the plate does not provide sufficient stability or if the bone fragments are not properly aligned, there is a risk of non-union (failure of the bone to heal) or malunion (improper bone healing), which may require further surgery.
In some cases, the plate or screws may cause irritation to the surrounding soft tissues, leading to discomfort or inflammation.
With the rise in motor vehicle accidents, sports injuries, and interpersonal violence, the demand for advanced facial fracture fixation devices is growing.
Innovations in surgical techniques, such as minimally invasive surgery, continue to enhance the adoption of implants like the 2.0 Maxillofacial Mini 90°L-Plate. The trend toward less invasive surgeries is expected to drive future growth.
As the global population ages, the incidence of fractures, including facial fractures, is likely to increase. This will further fuel the demand for facial reconstruction implants.
As healthcare systems in developing countries improve, there is an increasing demand for advanced implants and surgical tools, including the 2.0 Maxillofacial Mini 90°L-Plate.
Advances in 3D printing technology may allow for more personalized plates that are custom-designed to fit the unique anatomical structures of individual patients, improving outcomes and patient satisfaction.
The 2.0 Maxillofacial Mini 90°L-Plate is a highly effective implant for treating facial fractures, offering a combination of strength, stability, and versatility. Its 90° angled design, locking screw mechanism, and biocompatible materials make it an ideal choice for reconstructive surgeries. Despite the inherent risks, including infection and nerve injury, careful surgical planning and technique can minimize complications and lead to positive patient outcomes.
As the field of maxillofacial surgery continues to evolve, the 2.0 Maxillofacial Mini 90°L-Plate is likely to remain an essential tool for surgeons, offering reliable and durable solutions for facial fracture management. With continued advancements in surgical techniques and implant design, the future of this implant looks promising, with increased adoption in global markets.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini 90°L-Plate | RP2H419L2L | 4 holes, 0.8mm, 19mm, Left | |
RP2H419L2R | 4 holes, 0.8mm, 19mm, Right | ||
RP2H423L2L | 4 holes, 0.8mm, 23mm, Left | ||
RP2H423L2R | 4 holes, 0.8mm, 23mm, Right |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini 90°L-Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini 90°L-Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini 90°L-Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini 90°L-Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini 90°L-Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini 90°L-Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini 90°L-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini 90°L-Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini 90°L-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini 90°L-Plate is an innovative orthopedic implant designed specifically for the delicate structures of the maxillofacial region. This plate is widely used in reconstructive surgeries, particularly in the treatment of fractures involving the zygoma, mandible, and orbital bones. Its design enables precise and secure fixation, offering both functional and aesthetic benefits. This comprehensive guide explores the features, advantages, clinical applications, potential risks, and the future market of this implant.
The 2.0 Maxillofacial Mini 90°L-Plate is a small, specialized implant used in maxillofacial surgery to stabilize fractures in the facial skeleton. It is typically made from biocompatible materials such as titanium or stainless steel, which are both strong and lightweight. The "90°" refers to the angle between the arms of the "L"-shaped plate, which is designed to provide enhanced mechanical stability and precise alignment during fracture fixation.
This plate is used in procedures requiring small and delicate plates for the reconstruction of facial fractures, including those of the mandible, zygomatic arch, and orbital rim. Its small size makes it ideal for minimally invasive surgeries, providing reduced trauma to surrounding tissues.
The L-Plate's unique design, with a 90° angle between the two arms, ensures optimal stabilization of fractures requiring angular support. This design enhances fixation, especially in fractures involving complex geometries.
The plate is compact, making it suitable for use in small, intricate areas of the face. Its small profile allows for minimal surgical access, promoting quicker recovery and less scarring.
This plate can be used with locking screws, which provide superior fixation compared to traditional plates, ensuring that the bone fragments remain securely aligned during the healing process.
The plate is often pre-contoured to closely match the natural contours of the maxillofacial bones. This reduces the need for extensive adjustments during surgery.
Made from medical-grade titanium or stainless steel, the plate is both strong and lightweight. Titanium, in particular, is favored for its resistance to corrosion and its biocompatibility, ensuring that the body will accept the implant with minimal adverse reactions.
The 90° design and locking screws provide rigid fixation, significantly reducing the chances of malunion or non-union. This ensures that the bone fragments are held in place during the healing process, leading to better outcomes.
Due to its small size and pre-contoured shape, the plate facilitates minimally invasive surgical techniques. This reduces soft tissue damage, leading to quicker recovery, less post-operative pain, and smaller scars.
The stability and rigidity provided by the locking mechanism allow for faster bone healing. With proper stabilization, patients often experience reduced swelling and faster functional recovery.
The plate's precision and adaptability to the anatomy of the maxillofacial region help minimize complications, such as plate migration, screw loosening, or infection.
The plate can be applied to a variety of maxillofacial fractures, including those in the mandible, zygomatic arch, and orbital rim, making it a versatile tool in the reconstructive surgeon's arsenal.
The plate is commonly used in the treatment of fractures to the zygomatic arch or malar bones. Its design helps in restoring the facial contour and ensuring proper alignment.
The plate is highly effective in stabilizing fractures of the mandibular body or ramus, providing support for the bony structures that are crucial for chewing and speaking.
The plate is also used in treating fractures of the orbital rim, a common site for trauma. Its rigid fixation helps restore the anatomical structure of the eye socket and prevents further injury to the eye or optic nerve.
In cases of Le Fort I, II, and III fractures, the plate helps to stabilize the maxilla and mid-face, ensuring the correct alignment of the facial bones during the healing process.
The mini L-Plate is often used in post-traumatic reconstruction of the facial skeleton,helping to restore both function and aesthetic appearance.
As with any surgical procedure involving implants, there is a risk of infection at the incision or around the implant site. Strict sterile techniques must be followed to minimize this risk.
Due to the proximity of the facial nerves, there is a risk of nerve damage during surgery. This can lead to temporary or permanent sensory or motor deficits, such as numbness or paralysis of facial muscles.
While the plate is designed for durability, it can still fail due to factors such as inadequate screw fixation, trauma during recovery, or excessive mechanical stress on the plate.
If the plate does not provide sufficient stability or if the bone fragments are not properly aligned, there is a risk of non-union (failure of the bone to heal) or malunion (improper bone healing), which may require further surgery.
In some cases, the plate or screws may cause irritation to the surrounding soft tissues, leading to discomfort or inflammation.
With the rise in motor vehicle accidents, sports injuries, and interpersonal violence, the demand for advanced facial fracture fixation devices is growing.
Innovations in surgical techniques, such as minimally invasive surgery, continue to enhance the adoption of implants like the 2.0 Maxillofacial Mini 90°L-Plate. The trend toward less invasive surgeries is expected to drive future growth.
As the global population ages, the incidence of fractures, including facial fractures, is likely to increase. This will further fuel the demand for facial reconstruction implants.
As healthcare systems in developing countries improve, there is an increasing demand for advanced implants and surgical tools, including the 2.0 Maxillofacial Mini 90°L-Plate.
Advances in 3D printing technology may allow for more personalized plates that are custom-designed to fit the unique anatomical structures of individual patients, improving outcomes and patient satisfaction.
The 2.0 Maxillofacial Mini 90°L-Plate is a highly effective implant for treating facial fractures, offering a combination of strength, stability, and versatility. Its 90° angled design, locking screw mechanism, and biocompatible materials make it an ideal choice for reconstructive surgeries. Despite the inherent risks, including infection and nerve injury, careful surgical planning and technique can minimize complications and lead to positive patient outcomes.
As the field of maxillofacial surgery continues to evolve, the 2.0 Maxillofacial Mini 90°L-Plate is likely to remain an essential tool for surgeons, offering reliable and durable solutions for facial fracture management. With continued advancements in surgical techniques and implant design, the future of this implant looks promising, with increased adoption in global markets.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact