RP2H
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Straight Plate | RP2H635Z2 | 6 holes, 0.8mm, 35mm | |
RP2H847Z2 | 8 holes, 0.8mm, 47mm | ||
RP2H1059Z2 | 10 holes, 0.8mm, 59mm | ||
RP2H1271Z2 | 12 holes, 0.8mm, 71mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Straight Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Straight Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Straight Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Straight Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Straight Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Straight Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Straight Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Straight Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Straight Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini Straight Plate is an advanced orthopedic implant used in the fixation of fractures in the delicate bones of the maxillofacial region. As a part of the growing field of maxillofacial reconstructive surgery, this implant plays a vital role in restoring both function and appearance following trauma or congenital defects. This comprehensive guide explores the characteristics, benefits, risks, and future potential of the 2.0 Maxillofacial Mini Straight Plate, aiming to provide medical professionals, students, and patients with a clear understanding of its significance in clinical practice.
The 2.0 Maxillofacial Mini Straight Plate is a small, flat orthopedic implant designed specifically for the fixation of fractures in the maxillofacial region, such as the mandible, zygomatic arch, and orbital rims. Made from durable, biocompatible materials like titanium or stainless steel, it provides strong, reliable support for the bones while minimizing the risk of infection or rejection.
The "2.0" refers to the plate's specific design, optimized for use in small, delicate areas, with a thickness of 2.0 mm. Its straight configuration allows for easy alignment of the fractured bones, making it particularly suitable for linear fractures or fractures in areas requiring straightforward bone stabilization.
The straight structure of the plate ensures easy alignment with fractured bones, making it ideal for linear or uncomplicated fractures. It provides solid and direct support to maintain bone position during the healing process.
The plate is typically used with locking screws, which provide additional stability and prevent screw loosening over time. This is particularly beneficial for maintaining long-term fixation and preventing complications.
Designed for the maxillofacial region, the plate is compact, which allows it to fit easily into small bone structures without causing damage to surrounding tissues. Its precision design ensures minimal disruption to soft tissues and reduces surgical time.
The titanium or stainless steel materials used in the plate provide high strength, resistance to corrosion, and biocompatibility, ensuring that the plate remains functional over time while being well tolerated by the body.
Many 2.0 Maxillofacial Mini Straight Plates are pre-contoured to match the natural shape of facial bones. This feature allows for quicker, more efficient surgery with less intraoperative adjustment required.
The locking mechanism, combined with the straight design, ensures enhanced stability for the fractured bones. This reduces the likelihood of non-union or malunion and promotes proper bone healing.
The small size of the plate makes it ideal for minimally invasive surgical techniques. With smaller incisions and reduced dissection of soft tissues, the procedure results in less pain, reduced scarring, and faster recovery for the patient.
By using locking screws and minimizing the amount of hardware required, the plate reduces the risk of implant failure and soft tissue irritation, leading to lower chances of infection and post-operative complications.
The 2.0 Maxillofacial Mini Straight Plate can be used for a variety of fracture types, including those in the mandible, zygomatic bones, and orbital region. Its adaptability makes it a go-to option in maxillofacial reconstructive surgery.
Facial fractures often require reconstruction with aesthetic outcomes in mind. The plate helps restore the natural shape of the face while maintaining symmetry and function.
Fractures involving the mandible, particularly in the body or symphysis area, are commonly treated with the 2.0 straight plate. The plate provides sufficient stability for the restoration of chewing function and facial appearance.
The plate is frequently used to stabilize fractures of the zygomatic arch or malar bones, which are crucial in preserving facial structure and function. Its straight design ensures a proper fit, facilitating the alignment of fractured bone segments.
Orbital rim fractures, which may affect vision or lead to facial asymmetry, can also be effectively managed with the 2.0 Maxillofacial Mini Straight Plate. The plate's precise fit aids in restoring the normal contour of the orbital rim, improving both function and appearance.
The mini straight plate is sometimes used in Le Fort I, II, and III fractures, where the maxilla is fractured. This enables reconstruction of the mid-face and improves the patient's ability to chew, breathe, and speak.
In patients who have experienced trauma, the plate provides a reliable method for restoring bone integrity and facial aesthetics after fractures from accidents, falls, or violence.
As with any implant, there is a risk of infection following surgery. Proper sterilization techniques and post-operative care, such as antibiotics, are essential to minimizing this risk.
The proximity of facial nerves during surgery increases the possibility of nerve damage. Sensory deficits, such as numbness, or motor deficits, such as weakness or paralysis in facial muscles, may occur, although these complications are rare.
While the locking mechanism enhances stability, there is still a small risk of plate failure or migration. Over time, mechanical stress, trauma, or complications with the healing process may result in the need for revision surgery.
Improper alignment or inadequate stabilization of the fracture during surgery can lead to malunion (incorrect bone healing) or non-union (failure of the bone to heal). Proper surgical technique and post-operative care are crucial to avoid these issues.
In some cases, the plate may irritate surrounding tissues, causing inflammation or discomfort. This can sometimes lead to wound complications or the need for implant removal.
As the global population continues to grow and urbanization increases, the incidence of facial fractures due to trauma, accidents, and violence is expected to rise. This will increase demand for effective fracture fixation devices like the 2.0 Maxillofacial Mini Straight Plate.
With ongoing improvements in surgical techniques and materials, including 3D printing for custom implants, the future of maxillofacial reconstructive surgery will involve even more precise and personalized solutions. Plates like the 2.0 Mini Straight Plate are likely to evolve in line with these advances.
An aging population with increased rates of bone fragility and fractures, particularly in the mandible and zygomatic bones, will drive the demand for these implants. The ability of the plate to restore function and aesthetics in older adults is an important consideration.
As healthcare infrastructure improves in developing regions, the demand for advanced medical devices, including maxillofacial implants, is likely to expand. This creates significant growth opportunities for the 2.0 Maxillofacial Mini Straight Plate in global markets.
The 2.0 Maxillofacial Mini Straight Plate plays an essential role in maxillofacial reconstructive surgery, providing a stable and effective solution for treating fractures in the face. With its small size, locking mechanism, and precision design, the plate offers numerous advantages, including enhanced stability, minimally invasive procedures, and aesthetic outcomes.
While there are some risks associated with its use, such as infection or nerve injury, these can be managed with proper surgical techniques and aftercare. The future market for the plate looks promising, driven by factors such as an aging population, increasing facial trauma cases, and advancements in surgical technology.
In summary, the 2.0 Maxillofacial Mini Straight Plate remains a versatile, reliable implant that plays a crucial role in restoring both function and aesthetics in patients who require maxillofacial fracture fixation.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Straight Plate | RP2H635Z2 | 6 holes, 0.8mm, 35mm | |
RP2H847Z2 | 8 holes, 0.8mm, 47mm | ||
RP2H1059Z2 | 10 holes, 0.8mm, 59mm | ||
RP2H1271Z2 | 12 holes, 0.8mm, 71mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Straight Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Straight Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Straight Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Straight Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Straight Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Straight Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Straight Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Straight Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Straight Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini Straight Plate is an advanced orthopedic implant used in the fixation of fractures in the delicate bones of the maxillofacial region. As a part of the growing field of maxillofacial reconstructive surgery, this implant plays a vital role in restoring both function and appearance following trauma or congenital defects. This comprehensive guide explores the characteristics, benefits, risks, and future potential of the 2.0 Maxillofacial Mini Straight Plate, aiming to provide medical professionals, students, and patients with a clear understanding of its significance in clinical practice.
The 2.0 Maxillofacial Mini Straight Plate is a small, flat orthopedic implant designed specifically for the fixation of fractures in the maxillofacial region, such as the mandible, zygomatic arch, and orbital rims. Made from durable, biocompatible materials like titanium or stainless steel, it provides strong, reliable support for the bones while minimizing the risk of infection or rejection.
The "2.0" refers to the plate's specific design, optimized for use in small, delicate areas, with a thickness of 2.0 mm. Its straight configuration allows for easy alignment of the fractured bones, making it particularly suitable for linear fractures or fractures in areas requiring straightforward bone stabilization.
The straight structure of the plate ensures easy alignment with fractured bones, making it ideal for linear or uncomplicated fractures. It provides solid and direct support to maintain bone position during the healing process.
The plate is typically used with locking screws, which provide additional stability and prevent screw loosening over time. This is particularly beneficial for maintaining long-term fixation and preventing complications.
Designed for the maxillofacial region, the plate is compact, which allows it to fit easily into small bone structures without causing damage to surrounding tissues. Its precision design ensures minimal disruption to soft tissues and reduces surgical time.
The titanium or stainless steel materials used in the plate provide high strength, resistance to corrosion, and biocompatibility, ensuring that the plate remains functional over time while being well tolerated by the body.
Many 2.0 Maxillofacial Mini Straight Plates are pre-contoured to match the natural shape of facial bones. This feature allows for quicker, more efficient surgery with less intraoperative adjustment required.
The locking mechanism, combined with the straight design, ensures enhanced stability for the fractured bones. This reduces the likelihood of non-union or malunion and promotes proper bone healing.
The small size of the plate makes it ideal for minimally invasive surgical techniques. With smaller incisions and reduced dissection of soft tissues, the procedure results in less pain, reduced scarring, and faster recovery for the patient.
By using locking screws and minimizing the amount of hardware required, the plate reduces the risk of implant failure and soft tissue irritation, leading to lower chances of infection and post-operative complications.
The 2.0 Maxillofacial Mini Straight Plate can be used for a variety of fracture types, including those in the mandible, zygomatic bones, and orbital region. Its adaptability makes it a go-to option in maxillofacial reconstructive surgery.
Facial fractures often require reconstruction with aesthetic outcomes in mind. The plate helps restore the natural shape of the face while maintaining symmetry and function.
Fractures involving the mandible, particularly in the body or symphysis area, are commonly treated with the 2.0 straight plate. The plate provides sufficient stability for the restoration of chewing function and facial appearance.
The plate is frequently used to stabilize fractures of the zygomatic arch or malar bones, which are crucial in preserving facial structure and function. Its straight design ensures a proper fit, facilitating the alignment of fractured bone segments.
Orbital rim fractures, which may affect vision or lead to facial asymmetry, can also be effectively managed with the 2.0 Maxillofacial Mini Straight Plate. The plate's precise fit aids in restoring the normal contour of the orbital rim, improving both function and appearance.
The mini straight plate is sometimes used in Le Fort I, II, and III fractures, where the maxilla is fractured. This enables reconstruction of the mid-face and improves the patient's ability to chew, breathe, and speak.
In patients who have experienced trauma, the plate provides a reliable method for restoring bone integrity and facial aesthetics after fractures from accidents, falls, or violence.
As with any implant, there is a risk of infection following surgery. Proper sterilization techniques and post-operative care, such as antibiotics, are essential to minimizing this risk.
The proximity of facial nerves during surgery increases the possibility of nerve damage. Sensory deficits, such as numbness, or motor deficits, such as weakness or paralysis in facial muscles, may occur, although these complications are rare.
While the locking mechanism enhances stability, there is still a small risk of plate failure or migration. Over time, mechanical stress, trauma, or complications with the healing process may result in the need for revision surgery.
Improper alignment or inadequate stabilization of the fracture during surgery can lead to malunion (incorrect bone healing) or non-union (failure of the bone to heal). Proper surgical technique and post-operative care are crucial to avoid these issues.
In some cases, the plate may irritate surrounding tissues, causing inflammation or discomfort. This can sometimes lead to wound complications or the need for implant removal.
As the global population continues to grow and urbanization increases, the incidence of facial fractures due to trauma, accidents, and violence is expected to rise. This will increase demand for effective fracture fixation devices like the 2.0 Maxillofacial Mini Straight Plate.
With ongoing improvements in surgical techniques and materials, including 3D printing for custom implants, the future of maxillofacial reconstructive surgery will involve even more precise and personalized solutions. Plates like the 2.0 Mini Straight Plate are likely to evolve in line with these advances.
An aging population with increased rates of bone fragility and fractures, particularly in the mandible and zygomatic bones, will drive the demand for these implants. The ability of the plate to restore function and aesthetics in older adults is an important consideration.
As healthcare infrastructure improves in developing regions, the demand for advanced medical devices, including maxillofacial implants, is likely to expand. This creates significant growth opportunities for the 2.0 Maxillofacial Mini Straight Plate in global markets.
The 2.0 Maxillofacial Mini Straight Plate plays an essential role in maxillofacial reconstructive surgery, providing a stable and effective solution for treating fractures in the face. With its small size, locking mechanism, and precision design, the plate offers numerous advantages, including enhanced stability, minimally invasive procedures, and aesthetic outcomes.
While there are some risks associated with its use, such as infection or nerve injury, these can be managed with proper surgical techniques and aftercare. The future market for the plate looks promising, driven by factors such as an aging population, increasing facial trauma cases, and advancements in surgical technology.
In summary, the 2.0 Maxillofacial Mini Straight Plate remains a versatile, reliable implant that plays a crucial role in restoring both function and aesthetics in patients who require maxillofacial fracture fixation.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact