RP2H
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Arc Plate | RP2H634H2 | 6 holes, 0.8mm, 34mm | |
RP2H844H2 | 8 holes, 0.8mm, 44mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Arc Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Arc Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Arc Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Arc Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Arc Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Arc Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Arc Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Arc Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Arc Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini Arc Plate is an essential orthopedic implant used in the treatment of fractures in the maxillofacial region. Designed for small and delicate bones, this plate has become a critical tool in reconstructive surgery, providing both functional and aesthetic benefits to patients. This guide covers the features, advantages, surgical applications, and potential risks associated with the 2.0 Maxillofacial Mini Arc Plate, offering valuable insights for medical professionals and patients alike.
The 2.0 Maxillofacial Mini Arc Plate is a small, curved orthopedic implant used in the reconstruction of fractures within the maxillofacial skeleton. The plate is made from biocompatible materials, typically titanium or stainless steel, and features a smooth arc shape that allows it to fit naturally along the contours of facial bones. This arc design provides enhanced support and stability, particularly for fractures involving the zygomatic bone, mandible, and orbital rim.
The "2.0" designation refers to the plate's specific size, tailored for use in smaller, more intricate surgical areas. Its miniature dimensions make it ideal for minimally invasive surgeries, reducing soft tissue damage and promoting faster recovery.
The curved shape of the plate is specifically engineered to match the natural anatomy of the maxillofacial skeleton, ensuring a better fit and more effective support for fractured bones.
The miniaturized dimensions of the plate are designed for use in delicate, small bones of the face. This ensures minimal disruption to surrounding tissues, making the plate ideal for procedures requiring high precision.
The plate works with locking screws, which provide superior stability compared to traditional non-locking plates. This locking system helps prevent screw loosening over time, ensuring long-term stability of the fixation.
The plate is pre-contoured to fit specific facial areas, reducing the need for intraoperative bending and adjustments. This facilitates a more efficient and accurate surgical procedure.
The plate is typically made from titanium or stainless steel, both of which are known for their biocompatibility, strength, and resistance to corrosion. These materials ensure the plate remains stable and functional within the body over time.
The mini arc plate can be used for a wide variety of facial fractures, making it a versatile tool in maxillofacial surgery.
The locking mechanism combined with the arc design provides superior stability compared to traditional plates. This helps prevent the plate from shifting, leading to more secure fixation and reducing the risk of complications such as non-union or malunion.
Due to its small size and precise design, the plate is well-suited for minimally invasive surgery. Smaller incisions and reduced soft tissue dissection result in less pain, quicker recovery, and smaller scars.
The pre-contoured shape of the plate means less time spent on adjusting the plate to fit the bone. Surgeons can focus on the precise placement and securing of the implant, improving surgical efficiency.
The plate is designed to minimize soft tissue damage, which is particularly important for facial surgeries. This leads to better cosmetic outcomes and a more natural appearance after the surgery.
The titanium or stainless steel material ensures the plate remains durable over time, with little risk of degradation or weakening in the body. This contributes to a long-lasting solution for fracture fixation.
The plate is often used to stabilize fractures of the zygomatic arch or malar bones, which are common in facial trauma. The arc design ensures proper alignment of the bone fragments and restores facial symmetry.
The mini arc plate is effective for stabilizing fractures of the mandibular body or ramus. It helps restore function and aesthetic appearance, particularly in areas critical for chewing and speaking.
Fractures involving the orbital rim are commonly treated with the 2.0 Mini Arc Plate. The plate’s anatomical shape provides optimal stabilization for the delicate structures around the eyes.
In cases of Le Fort I, II, and III fractures, the plate can be used to stabilize the maxilla and restore the mid-face structure, contributing to both function and appearance.
The mini arc plate is also used in post-traumatic reconstruction to repair fractures resulting from accidents, violence, or surgical complications, ensuring long-term bone stability.
As with any surgical procedure involving implants, there is always a risk of infection. Proper sterile techniques and post-operative care are essential to minimize this risk.
The proximity of the facial nerves to the surgical site increases the risk of nerve damage during surgery. This can result in sensory deficits such as numbness or temporary paralysis in the facial muscles.
Though rare, there is a risk of the plate or screws failing, especially if excessive mechanical stress is applied to the implant. This can lead to plate migration, screw loosening, or the need for revision surgery.
If the fracture is not properly aligned or the plate does not provide sufficient stabilization, non-union or malunion can occur, which may necessitate additional interventions.
In some cases, the plate may cause irritation or discomfort to surrounding soft tissues, leading to inflammation or wound complications.
The increasing incidence of facial fractures, particularly due to accidents, sports injuries, and violence, is expected to drive demand for innovative fracture fixation devices like the mini arc plate.
As surgical techniques continue to improve, there will be greater adoption of minimally invasive procedures that utilize small, highly precise implants. The 2.0 Maxillofacial Mini Arc Plate fits well into this trend.
As the global population ages, the need for reconstructive surgeries in the facial region will increase, particularly for those suffering from bone loss or fractures due to osteoporosis or trauma.
The demand for advanced medical devices, including the mini arc plate, will continue to grow in emerging markets, where healthcare infrastructure is rapidly improving.
With the rise of customized implants made possible by 3D printing technology, future versions of the mini arc plate may offer even more tailored solutions for patients, ensuring better outcomes and reducing the risk of complications.
The 2.0 Maxillofacial Mini Arc Plate is an indispensable tool in the management of maxillofacial fractures, offering a combination of stability, minimal invasiveness, and aesthetic preservation. Its design allows for precise alignment of facial bones, reducing the risk of complications such as malunion or non-union, and promoting quicker recovery with minimal scarring.
While there are some risks associated with its use, such as infection and nerve injury, these can be mitigated through careful surgical planning and technique. As the demand for reconstructive surgeries increases, the 2.0 Maxillofacial Mini Arc Plate will likely play an even more prominent role in ensuring successful outcomes for patients with facial fractures. With technological advancements and a growing market, this implant's future looks promising, benefiting both surgeons and patients worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Arc Plate | RP2H634H2 | 6 holes, 0.8mm, 34mm | |
RP2H844H2 | 8 holes, 0.8mm, 44mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Arc Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Arc Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Arc Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Arc Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Arc Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Arc Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Arc Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Arc Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Arc Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini Arc Plate is an essential orthopedic implant used in the treatment of fractures in the maxillofacial region. Designed for small and delicate bones, this plate has become a critical tool in reconstructive surgery, providing both functional and aesthetic benefits to patients. This guide covers the features, advantages, surgical applications, and potential risks associated with the 2.0 Maxillofacial Mini Arc Plate, offering valuable insights for medical professionals and patients alike.
The 2.0 Maxillofacial Mini Arc Plate is a small, curved orthopedic implant used in the reconstruction of fractures within the maxillofacial skeleton. The plate is made from biocompatible materials, typically titanium or stainless steel, and features a smooth arc shape that allows it to fit naturally along the contours of facial bones. This arc design provides enhanced support and stability, particularly for fractures involving the zygomatic bone, mandible, and orbital rim.
The "2.0" designation refers to the plate's specific size, tailored for use in smaller, more intricate surgical areas. Its miniature dimensions make it ideal for minimally invasive surgeries, reducing soft tissue damage and promoting faster recovery.
The curved shape of the plate is specifically engineered to match the natural anatomy of the maxillofacial skeleton, ensuring a better fit and more effective support for fractured bones.
The miniaturized dimensions of the plate are designed for use in delicate, small bones of the face. This ensures minimal disruption to surrounding tissues, making the plate ideal for procedures requiring high precision.
The plate works with locking screws, which provide superior stability compared to traditional non-locking plates. This locking system helps prevent screw loosening over time, ensuring long-term stability of the fixation.
The plate is pre-contoured to fit specific facial areas, reducing the need for intraoperative bending and adjustments. This facilitates a more efficient and accurate surgical procedure.
The plate is typically made from titanium or stainless steel, both of which are known for their biocompatibility, strength, and resistance to corrosion. These materials ensure the plate remains stable and functional within the body over time.
The mini arc plate can be used for a wide variety of facial fractures, making it a versatile tool in maxillofacial surgery.
The locking mechanism combined with the arc design provides superior stability compared to traditional plates. This helps prevent the plate from shifting, leading to more secure fixation and reducing the risk of complications such as non-union or malunion.
Due to its small size and precise design, the plate is well-suited for minimally invasive surgery. Smaller incisions and reduced soft tissue dissection result in less pain, quicker recovery, and smaller scars.
The pre-contoured shape of the plate means less time spent on adjusting the plate to fit the bone. Surgeons can focus on the precise placement and securing of the implant, improving surgical efficiency.
The plate is designed to minimize soft tissue damage, which is particularly important for facial surgeries. This leads to better cosmetic outcomes and a more natural appearance after the surgery.
The titanium or stainless steel material ensures the plate remains durable over time, with little risk of degradation or weakening in the body. This contributes to a long-lasting solution for fracture fixation.
The plate is often used to stabilize fractures of the zygomatic arch or malar bones, which are common in facial trauma. The arc design ensures proper alignment of the bone fragments and restores facial symmetry.
The mini arc plate is effective for stabilizing fractures of the mandibular body or ramus. It helps restore function and aesthetic appearance, particularly in areas critical for chewing and speaking.
Fractures involving the orbital rim are commonly treated with the 2.0 Mini Arc Plate. The plate’s anatomical shape provides optimal stabilization for the delicate structures around the eyes.
In cases of Le Fort I, II, and III fractures, the plate can be used to stabilize the maxilla and restore the mid-face structure, contributing to both function and appearance.
The mini arc plate is also used in post-traumatic reconstruction to repair fractures resulting from accidents, violence, or surgical complications, ensuring long-term bone stability.
As with any surgical procedure involving implants, there is always a risk of infection. Proper sterile techniques and post-operative care are essential to minimize this risk.
The proximity of the facial nerves to the surgical site increases the risk of nerve damage during surgery. This can result in sensory deficits such as numbness or temporary paralysis in the facial muscles.
Though rare, there is a risk of the plate or screws failing, especially if excessive mechanical stress is applied to the implant. This can lead to plate migration, screw loosening, or the need for revision surgery.
If the fracture is not properly aligned or the plate does not provide sufficient stabilization, non-union or malunion can occur, which may necessitate additional interventions.
In some cases, the plate may cause irritation or discomfort to surrounding soft tissues, leading to inflammation or wound complications.
The increasing incidence of facial fractures, particularly due to accidents, sports injuries, and violence, is expected to drive demand for innovative fracture fixation devices like the mini arc plate.
As surgical techniques continue to improve, there will be greater adoption of minimally invasive procedures that utilize small, highly precise implants. The 2.0 Maxillofacial Mini Arc Plate fits well into this trend.
As the global population ages, the need for reconstructive surgeries in the facial region will increase, particularly for those suffering from bone loss or fractures due to osteoporosis or trauma.
The demand for advanced medical devices, including the mini arc plate, will continue to grow in emerging markets, where healthcare infrastructure is rapidly improving.
With the rise of customized implants made possible by 3D printing technology, future versions of the mini arc plate may offer even more tailored solutions for patients, ensuring better outcomes and reducing the risk of complications.
The 2.0 Maxillofacial Mini Arc Plate is an indispensable tool in the management of maxillofacial fractures, offering a combination of stability, minimal invasiveness, and aesthetic preservation. Its design allows for precise alignment of facial bones, reducing the risk of complications such as malunion or non-union, and promoting quicker recovery with minimal scarring.
While there are some risks associated with its use, such as infection and nerve injury, these can be mitigated through careful surgical planning and technique. As the demand for reconstructive surgeries increases, the 2.0 Maxillofacial Mini Arc Plate will likely play an even more prominent role in ensuring successful outcomes for patients with facial fractures. With technological advancements and a growing market, this implant's future looks promising, benefiting both surgeons and patients worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact