RQLG201
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Medical Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Products | Pictures | Details | ||||
Femoral Intramedullary Nail Instrument Set (PN:RQLG201) | 1 | N-03-01 | Femur Nail Tray | 1 | ||
2 | N-03-02 | Universal Joint | 1 | |||
3 | N-03-03 | Drill Sleeve | 1 | |||
4 | N-03-04 | Open Wrench | 1 | |||
5 | N-03-05 | Hex Wrench | 1 | |||
6 | N-03-06 | Hex Wrench | 1 | |||
7 | N-03-07 | Drill Sleeve | 1 | |||
8 | N-03-08 | Drill Sleeve | 1 | |||
9 | N-03-09 | Drill Sleeve | 1 | |||
10 | N-03-10 | Quick Coupling T-Handle | 1 | |||
11 | N-03-11 | Screwdriver | 1 | |||
12 | N-03-12 | T-handle Drill Bit | 2 | |||
13 | N-03-13 | Depth Gague 10-100mm | 1 | |||
14 | N-03-14 | Drill Bit 5.2*300mm | 1 | |||
15 | N-03-15 | Drill Bit φ4.0*300 | 1 | |||
16 | N-03-16 | Drill Bit with Limitator φ4.0*300 | 1 | |||
17 | N-03-17 | Reamer 10mm | 1 | |||
18 | N-03-18 | Reamer 11mm | 1 | |||
19 | N-03-19 | Reamer 12mm | 1 | |||
20 | N-03-20 | Reamer 13mm | 1 | |||
21 | N-03-21 | Distal Guider | 1 | |||
22 | N-03-22 | Connector | 1 | |||
23 | N-03-23 | Location Forcep | 1 | |||
24 | N-03-24 | Fixed Connector | 1 | |||
25 | N-03-25 | Location Rod | 1 | |||
26 | N-03-26 | Connector Rod | 1 | |||
27 | N-03-27 | Guide Rod | 1 | |||
28 | N-03-28 | Hammer | 1 | |||
29 | N-03-29 | Sighting Device Handle | 1 | |||
30 | N-03-30 | Bolt | 1 | |||
31 | N-03-31 | Bolt | 1 | |||
32 | N-03-32 | Bolt | 1 | |||
33 | N-03-33 | Bolt | 1 | |||
34 | N-03-34 | Nail Connector | 1 | |||
35 | N-03-35 | AWL | 1 | |||
36 | N-03-36 | Aluminium Box | 1 |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Femoral Intramedullary Nail Instrument Set Product Catalog.
2. Choose Your Interested Femoral Intramedullary Nail Instrument Set Product.
3. Ask For A Sample To Test Femoral Intramedullary Nail Instrument Set Quality.
4.Make An Order Of Xc Medico's Femoral Intramedullary Nail Instrument Set.
5.Become A Dealer Of Xc Medico's Femoral Intramedullary Nail Instrument Set.
1. Better Purchase Prices Of Femoral Intramedullary Nail Instrument Set.
2.100% The Highest Quality Femoral Intramedullary Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Femoral Intramedullary Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's Femoral Intramedullary Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Femoral intramedullary nail instrument sets are specialized surgical toolkits designed for the insertion and fixation of femoral intramedullary nails, which are used to treat fractures of the femur and the thigh bone. The set of instruments used for the femoral nailing procedure is built to simplify surgical steps while maintaining maximum accuracy and efficiency. the instruments in the set are designed to allow the surgeon to achieve stable fixation by inserting the nail through a minimal incision, which reduces tissue damage and promotes faster recovery for patients. this set also includes modularity, where different nail lengths, diameters, and locking options can be adapted to cater to a wide variety of fracture patterns and patient anatomies.
The instruments should be compatible with various types of femoral intramedullary nails, including locking and non-locking nails.
The instruments should be designed for comfort and ease of use, reducing surgeon fatigue and improving surgical precision.
The instruments should be made from high-quality materials that can withstand the rigors of surgical procedures.
The instruments should be designed to provide accurate and precise placement of the intramedullary nail
A well-equipped femoral intramedullary nail instrument set can streamline the surgical procedure, reducing operating time and improving patient outcomes.
The use of specialized instruments can enhance the accuracy of nail placement, reducing the risk of complications.
A comprehensive set can be used to treat a wide range of femoral fractures, including simple and complex fractures.
The surgeon must perform a preoperative assessment of the patient's anatomy and fracture pattern. Proper selection of the size and length of the intramedullary nail is critical, as an inappropriately sized nail can lead to complications such as malposition or implant failure. A thorough understanding of the patient's bone quality, especially in patients with osteoporosis, is also essential for selecting the appropriate instrumentation. Maintaining a sterile environment throughout the procedure is essential to minimize the risk of postoperative infection. Each component of the instrument set must be sterilized according to established protocols. The surgeon must also be careful and cautious when reaming the femoral canal to avoid removing too much bone. Accurate positioning of the intramedullary nail and locking screw is critical. Improper positioning of the intramedullary nail or screw can lead to rotational instability, improper load distribution, or nonunion.
The femoral intramedullary nail instrument set market will witness significant growth in the coming years due to advancements in orthopedic technology, an aging population, an increase in the number of fractures, and the need for minimally invasive orthopedic surgical solutions. These factors are reshaping the landscape of trauma care and orthopedic surgery, positioning the femoral intramedullary nail instrument set as an essential component of fracture management in the coming years.
In conclusion, femoral intramedullary nail instrument sets are essential tools for orthopedic surgeons treating tibial fractures. By selecting a high-quality instrument set, surgeons can improve the efficiency, accuracy, and outcomes of their procedures.
Products | Pictures | Details | ||||
Femoral Intramedullary Nail Instrument Set (PN:RQLG201) | 1 | N-03-01 | Femur Nail Tray | 1 | ||
2 | N-03-02 | Universal Joint | 1 | |||
3 | N-03-03 | Drill Sleeve | 1 | |||
4 | N-03-04 | Open Wrench | 1 | |||
5 | N-03-05 | Hex Wrench | 1 | |||
6 | N-03-06 | Hex Wrench | 1 | |||
7 | N-03-07 | Drill Sleeve | 1 | |||
8 | N-03-08 | Drill Sleeve | 1 | |||
9 | N-03-09 | Drill Sleeve | 1 | |||
10 | N-03-10 | Quick Coupling T-Handle | 1 | |||
11 | N-03-11 | Screwdriver | 1 | |||
12 | N-03-12 | T-handle Drill Bit | 2 | |||
13 | N-03-13 | Depth Gague 10-100mm | 1 | |||
14 | N-03-14 | Drill Bit 5.2*300mm | 1 | |||
15 | N-03-15 | Drill Bit φ4.0*300 | 1 | |||
16 | N-03-16 | Drill Bit with Limitator φ4.0*300 | 1 | |||
17 | N-03-17 | Reamer 10mm | 1 | |||
18 | N-03-18 | Reamer 11mm | 1 | |||
19 | N-03-19 | Reamer 12mm | 1 | |||
20 | N-03-20 | Reamer 13mm | 1 | |||
21 | N-03-21 | Distal Guider | 1 | |||
22 | N-03-22 | Connector | 1 | |||
23 | N-03-23 | Location Forcep | 1 | |||
24 | N-03-24 | Fixed Connector | 1 | |||
25 | N-03-25 | Location Rod | 1 | |||
26 | N-03-26 | Connector Rod | 1 | |||
27 | N-03-27 | Guide Rod | 1 | |||
28 | N-03-28 | Hammer | 1 | |||
29 | N-03-29 | Sighting Device Handle | 1 | |||
30 | N-03-30 | Bolt | 1 | |||
31 | N-03-31 | Bolt | 1 | |||
32 | N-03-32 | Bolt | 1 | |||
33 | N-03-33 | Bolt | 1 | |||
34 | N-03-34 | Nail Connector | 1 | |||
35 | N-03-35 | AWL | 1 | |||
36 | N-03-36 | Aluminium Box | 1 |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Femoral Intramedullary Nail Instrument Set Product Catalog.
2. Choose Your Interested Femoral Intramedullary Nail Instrument Set Product.
3. Ask For A Sample To Test Femoral Intramedullary Nail Instrument Set Quality.
4.Make An Order Of Xc Medico's Femoral Intramedullary Nail Instrument Set.
5.Become A Dealer Of Xc Medico's Femoral Intramedullary Nail Instrument Set.
1. Better Purchase Prices Of Femoral Intramedullary Nail Instrument Set.
2.100% The Highest Quality Femoral Intramedullary Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Femoral Intramedullary Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's Femoral Intramedullary Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Femoral intramedullary nail instrument sets are specialized surgical toolkits designed for the insertion and fixation of femoral intramedullary nails, which are used to treat fractures of the femur and the thigh bone. The set of instruments used for the femoral nailing procedure is built to simplify surgical steps while maintaining maximum accuracy and efficiency. the instruments in the set are designed to allow the surgeon to achieve stable fixation by inserting the nail through a minimal incision, which reduces tissue damage and promotes faster recovery for patients. this set also includes modularity, where different nail lengths, diameters, and locking options can be adapted to cater to a wide variety of fracture patterns and patient anatomies.
The instruments should be compatible with various types of femoral intramedullary nails, including locking and non-locking nails.
The instruments should be designed for comfort and ease of use, reducing surgeon fatigue and improving surgical precision.
The instruments should be made from high-quality materials that can withstand the rigors of surgical procedures.
The instruments should be designed to provide accurate and precise placement of the intramedullary nail
A well-equipped femoral intramedullary nail instrument set can streamline the surgical procedure, reducing operating time and improving patient outcomes.
The use of specialized instruments can enhance the accuracy of nail placement, reducing the risk of complications.
A comprehensive set can be used to treat a wide range of femoral fractures, including simple and complex fractures.
The surgeon must perform a preoperative assessment of the patient's anatomy and fracture pattern. Proper selection of the size and length of the intramedullary nail is critical, as an inappropriately sized nail can lead to complications such as malposition or implant failure. A thorough understanding of the patient's bone quality, especially in patients with osteoporosis, is also essential for selecting the appropriate instrumentation. Maintaining a sterile environment throughout the procedure is essential to minimize the risk of postoperative infection. Each component of the instrument set must be sterilized according to established protocols. The surgeon must also be careful and cautious when reaming the femoral canal to avoid removing too much bone. Accurate positioning of the intramedullary nail and locking screw is critical. Improper positioning of the intramedullary nail or screw can lead to rotational instability, improper load distribution, or nonunion.
The femoral intramedullary nail instrument set market will witness significant growth in the coming years due to advancements in orthopedic technology, an aging population, an increase in the number of fractures, and the need for minimally invasive orthopedic surgical solutions. These factors are reshaping the landscape of trauma care and orthopedic surgery, positioning the femoral intramedullary nail instrument set as an essential component of fracture management in the coming years.
In conclusion, femoral intramedullary nail instrument sets are essential tools for orthopedic surgeons treating tibial fractures. By selecting a high-quality instrument set, surgeons can improve the efficiency, accuracy, and outcomes of their procedures.
Contact