RQPFNA01
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Medical Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Products | Pictures | Details | |||||
PFNA Nail Instrument Set (PN:RQPFNA01) | 1 | N-07-01 | Connector | 1 | |||
2 | N-07-02 | AWL | 1 | ||||
3 | N-07-03 | Guider Wire Holder | 1 | ||||
4 | N-07-04 | Drill Sleeve | 1 | ||||
5 | N-07-05 | Drill Sleeve | 1 | ||||
6 | N-07-06 | Position Rod | 1 | ||||
7 | N-07-07 | Position Drill Bit | 1 | ||||
8 | N-07-08 | Drill Bit Ø4.3 | 1 | ||||
9 | N-07-09 | Position Drill | 1 | ||||
10 | N-07-10 | Screwdriver Hex SW2.5 | 1 | ||||
11 | N-07-11 | Tissue Protection Plate | 1 | ||||
12 | N-07-12 | Depth Gague 0-100mm | 1 | ||||
13 | N-07-13 | Blade Screw Device | 1 | ||||
14 | N-07-14 | Nail Removal Rod | 1 | ||||
15 | N-07-15 | Template for Development | 1 | ||||
16 | N-07-16 | Cannulated Screwdriver | 1 | ||||
17 | N-07-17 | Tail Cannulated Screwdriver | 1 | ||||
18 | N-07-18 | Distal Guider Device 90° 180/240 | 1 | ||||
19 | N-07-19 | Distal Guider Device 240 | 1 | ||||
20 | N-07-20 | Distal Guider Device 180 | 1 | ||||
21 | N-07-21 | Distal Position Lock | 1 | ||||
22 | N-07-22 | Handle | 1 | ||||
23 | N-07-23 | Guider Sleeve | 1 | ||||
24 | N-07-24 | Open Wrench | 1 | ||||
25 | N-07-25 | Main Pin Impactor | 1 | ||||
26 | N-07-26 | Hex Key Large | 1 | ||||
27 | N-07-27 | Hex Key Small | 1 | ||||
28 | N-07-28 | Bolt | 1 | ||||
29 | N-07-29 | Nut Screwdriver | 1 | ||||
30 | N-07-30 | Drill Sleeve | 1 | ||||
31 | N-07-31 | Quick Coupling T-handle+Proximal HollowD | 1 | ||||
32 | N-07-32 | Proximal Hollow Position Stopper | 1 | ||||
33 | N-07-33 | Long Nail Distal Guider Bar | 1 | ||||
34 | N-07-34 | Reamer Head 8.5-13mm | 1 | ||||
35 | N-07-35 | End Cap Guider | 1 | ||||
36 | N-07-36 | Threaded K-Wire | 4 | ||||
37 | N-07-37 | Flexible Reamer Bar | 1 | ||||
38 | N-07-38 | Long Nail Distal Guider Bar | 1 | ||||
39 | N-07-39 | Bolt | 1 | ||||
40 | N-07-40 | Reduction Rod | 1 | ||||
41 | N-07-41 | Depth Gague 70-120mm | 1 | ||||
42 | N-07-42 | Wrench | 1 | ||||
43 | N-07-43 | Long Nail Distal Screw Location Device | 1 | ||||
44 | N-07-44 | Bolt | 1 | ||||
45 | N-07-45 | Bolt | 1 | ||||
46 | N-07-46 | Proximal Guider Device | 1 | ||||
47 | N-07-47 | Guider Sleeve | 1 | ||||
48 | N-07-48 | Saw Blade Screwdriver | 1 | ||||
49 | N-07-49 | Hammer | 1 | ||||
50 | N-07-50 | Slide Hammer | 1 | ||||
51 | N-07-51 | Olive Guide Wire | 1 | ||||
52 | N-07-52 | Aluminium Box | 1 |
The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. |
Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. |
Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For PFNA Nail Instrument Set Product Catalog.
2. Choose Your Interested PFNA Nail Instrument Set Product.
3. Ask For A Sample To Test PFNA Nail Instrument Set Quality.
4.Make An Order Of Xc Medico's PFNA Nail Instrument Set.
5.Become A Dealer Of Xc Medico's PFNA Nail Instrument Set.
1. Better Purchase Prices Of PFNA Nail Instrument Set.
2.100% The Highest Quality PFNA Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient PFNA Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's PFNA Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The primary application of the PFNA nail instrument set is to treat complex proximal femoral fractures, particularly in elderly patients with osteoporosis. The instrument set includes various specialized tools, such as targeting devices, reamers, guidewires, insertion handles, and helical blades. Each component ensures precise nail insertion, alignment, and secure fixation.
The instrument set includes targeting guides and insertion handles that assist in the accurate placement of the nail and helical blade. These guides help achieve precise alignment, critical for the anti-rotation feature of the PFNA system.
Different sizes of reamers are included to prepare the femoral canal, ensuring a snug fit for the nail and reducing the risk of implant migration. Proper reaming also helps in accommodating the nail without compromising the bone's structural integrity.
A key feature of the PFNA system is the helical blade, which is designed to compress the trabecular bone within the femoral head, providing secure anchorage and resistance to rotational forces. This is particularly beneficial in osteoporotic bone.
The PFNA instrument set often includes a radiolucent aiming arm that allows for clear fluoroscopic visualization, aiding surgeons in precise nail and blade placement without interference from metal components.
The PFNA nail and its associated instruments are made from high-grade titanium or stainless steel, which are biocompatible, durable, and capable of withstanding the physical demands of femoral load-bearing.
PFNA nails are specifically designed to stabilize fractures in osteoporotic bone, making them ideal for elderly patients.
The PFNA nail's minimally invasive placement requires smaller incisions and reduces trauma to surrounding tissue, leading to less post-operative pain, quicker recovery, and fewer complications.
The anti-rotation feature of the PFNA nail decreases the likelihood of implant failure by preventing rotational movement in the femoral head.
The PFNA system is adaptable to various proximal femoral fractures, including intertrochanteric and subtrochanteric fractures, offering a versatile solution for trauma surgeons.
To prevent infection, all instruments must be meticulously sterilized before each procedure. This is particularly important for elderly patients, who may have compromised immune systems and are more susceptible to infections.
Excessive reaming can weaken the femoral canal and lead to bone damage. Surgeons should use the reamers cautiously to create the optimal canal size for the PFNA nail without compromising the bone structure.
Accurate positioning of the helical blade within the femoral head is crucial for anti-rotation stability.
PFNA Nail Instrument Set is a valuable tool for orthopedic surgeons to treat proximal femoral fractures, especially in elderly patients. Its minimally invasive approach, stable fixation, and potential for faster recovery make it a preferred choice for many surgeons. However, proper use and adherence to surgical protocols are essential to achieve optimal outcomes.
In conclusion, PFNA nail instrument sets are the tool of choice for orthopedic surgeons treating femoral fractures( especially in the elderly). By choosing a high-quality instrument set, surgeons can improve their procedures' efficiency, accuracy, and effectiveness.
Products | Pictures | Details | |||||
PFNA Nail Instrument Set (PN:RQPFNA01) | 1 | N-07-01 | Connector | 1 | |||
2 | N-07-02 | AWL | 1 | ||||
3 | N-07-03 | Guider Wire Holder | 1 | ||||
4 | N-07-04 | Drill Sleeve | 1 | ||||
5 | N-07-05 | Drill Sleeve | 1 | ||||
6 | N-07-06 | Position Rod | 1 | ||||
7 | N-07-07 | Position Drill Bit | 1 | ||||
8 | N-07-08 | Drill Bit Ø4.3 | 1 | ||||
9 | N-07-09 | Position Drill | 1 | ||||
10 | N-07-10 | Screwdriver Hex SW2.5 | 1 | ||||
11 | N-07-11 | Tissue Protection Plate | 1 | ||||
12 | N-07-12 | Depth Gague 0-100mm | 1 | ||||
13 | N-07-13 | Blade Screw Device | 1 | ||||
14 | N-07-14 | Nail Removal Rod | 1 | ||||
15 | N-07-15 | Template for Development | 1 | ||||
16 | N-07-16 | Cannulated Screwdriver | 1 | ||||
17 | N-07-17 | Tail Cannulated Screwdriver | 1 | ||||
18 | N-07-18 | Distal Guider Device 90° 180/240 | 1 | ||||
19 | N-07-19 | Distal Guider Device 240 | 1 | ||||
20 | N-07-20 | Distal Guider Device 180 | 1 | ||||
21 | N-07-21 | Distal Position Lock | 1 | ||||
22 | N-07-22 | Handle | 1 | ||||
23 | N-07-23 | Guider Sleeve | 1 | ||||
24 | N-07-24 | Open Wrench | 1 | ||||
25 | N-07-25 | Main Pin Impactor | 1 | ||||
26 | N-07-26 | Hex Key Large | 1 | ||||
27 | N-07-27 | Hex Key Small | 1 | ||||
28 | N-07-28 | Bolt | 1 | ||||
29 | N-07-29 | Nut Screwdriver | 1 | ||||
30 | N-07-30 | Drill Sleeve | 1 | ||||
31 | N-07-31 | Quick Coupling T-handle+Proximal HollowD | 1 | ||||
32 | N-07-32 | Proximal Hollow Position Stopper | 1 | ||||
33 | N-07-33 | Long Nail Distal Guider Bar | 1 | ||||
34 | N-07-34 | Reamer Head 8.5-13mm | 1 | ||||
35 | N-07-35 | End Cap Guider | 1 | ||||
36 | N-07-36 | Threaded K-Wire | 4 | ||||
37 | N-07-37 | Flexible Reamer Bar | 1 | ||||
38 | N-07-38 | Long Nail Distal Guider Bar | 1 | ||||
39 | N-07-39 | Bolt | 1 | ||||
40 | N-07-40 | Reduction Rod | 1 | ||||
41 | N-07-41 | Depth Gague 70-120mm | 1 | ||||
42 | N-07-42 | Wrench | 1 | ||||
43 | N-07-43 | Long Nail Distal Screw Location Device | 1 | ||||
44 | N-07-44 | Bolt | 1 | ||||
45 | N-07-45 | Bolt | 1 | ||||
46 | N-07-46 | Proximal Guider Device | 1 | ||||
47 | N-07-47 | Guider Sleeve | 1 | ||||
48 | N-07-48 | Saw Blade Screwdriver | 1 | ||||
49 | N-07-49 | Hammer | 1 | ||||
50 | N-07-50 | Slide Hammer | 1 | ||||
51 | N-07-51 | Olive Guide Wire | 1 | ||||
52 | N-07-52 | Aluminium Box | 1 |
The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. |
Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. |
Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For PFNA Nail Instrument Set Product Catalog.
2. Choose Your Interested PFNA Nail Instrument Set Product.
3. Ask For A Sample To Test PFNA Nail Instrument Set Quality.
4.Make An Order Of Xc Medico's PFNA Nail Instrument Set.
5.Become A Dealer Of Xc Medico's PFNA Nail Instrument Set.
1. Better Purchase Prices Of PFNA Nail Instrument Set.
2.100% The Highest Quality PFNA Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient PFNA Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's PFNA Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The primary application of the PFNA nail instrument set is to treat complex proximal femoral fractures, particularly in elderly patients with osteoporosis. The instrument set includes various specialized tools, such as targeting devices, reamers, guidewires, insertion handles, and helical blades. Each component ensures precise nail insertion, alignment, and secure fixation.
The instrument set includes targeting guides and insertion handles that assist in the accurate placement of the nail and helical blade. These guides help achieve precise alignment, critical for the anti-rotation feature of the PFNA system.
Different sizes of reamers are included to prepare the femoral canal, ensuring a snug fit for the nail and reducing the risk of implant migration. Proper reaming also helps in accommodating the nail without compromising the bone's structural integrity.
A key feature of the PFNA system is the helical blade, which is designed to compress the trabecular bone within the femoral head, providing secure anchorage and resistance to rotational forces. This is particularly beneficial in osteoporotic bone.
The PFNA instrument set often includes a radiolucent aiming arm that allows for clear fluoroscopic visualization, aiding surgeons in precise nail and blade placement without interference from metal components.
The PFNA nail and its associated instruments are made from high-grade titanium or stainless steel, which are biocompatible, durable, and capable of withstanding the physical demands of femoral load-bearing.
PFNA nails are specifically designed to stabilize fractures in osteoporotic bone, making them ideal for elderly patients.
The PFNA nail's minimally invasive placement requires smaller incisions and reduces trauma to surrounding tissue, leading to less post-operative pain, quicker recovery, and fewer complications.
The anti-rotation feature of the PFNA nail decreases the likelihood of implant failure by preventing rotational movement in the femoral head.
The PFNA system is adaptable to various proximal femoral fractures, including intertrochanteric and subtrochanteric fractures, offering a versatile solution for trauma surgeons.
To prevent infection, all instruments must be meticulously sterilized before each procedure. This is particularly important for elderly patients, who may have compromised immune systems and are more susceptible to infections.
Excessive reaming can weaken the femoral canal and lead to bone damage. Surgeons should use the reamers cautiously to create the optimal canal size for the PFNA nail without compromising the bone structure.
Accurate positioning of the helical blade within the femoral head is crucial for anti-rotation stability.
PFNA Nail Instrument Set is a valuable tool for orthopedic surgeons to treat proximal femoral fractures, especially in elderly patients. Its minimally invasive approach, stable fixation, and potential for faster recovery make it a preferred choice for many surgeons. However, proper use and adherence to surgical protocols are essential to achieve optimal outcomes.
In conclusion, PFNA nail instrument sets are the tool of choice for orthopedic surgeons treating femoral fractures( especially in the elderly). By choosing a high-quality instrument set, surgeons can improve their procedures' efficiency, accuracy, and effectiveness.
Contact