RQPG201
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Medical Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Products | Pictures | Details | |||||
Femoral Reconstruction Intramedullary NailInstrument Set (PNRQPG201) | 1 | N-05-01 | Solid Reamer Ø11 | 1 | |||
2 | N-05-02 | Solid Reamer Ø12 | 1 | ||||
3 | N-05-03 | Solid Reamer Ø12.5 | 1 | ||||
4 | N-05-04 | Solid Reamer Ø13 | 1 | ||||
5 | N-05-05 | Solid Reamer Ø10.4 | 1 | ||||
6 | N-05-06 | Drill Bit | 1 | ||||
7 | N-05-07 | Drill Bit With Limitator | 1 | ||||
8 | N-05-08 | Drill Bit | 1 | ||||
9 | N-05-09 | Depth Gague | 1 | ||||
10 | N-05-10 | Location Forcep | 1 | ||||
11 | N-05-11 | Drill Sleeve | 1 | ||||
12 | N-05-12 | Drill Sleeve | 1 | ||||
13 | N-05-13 | Drill Sleeve | 1 | ||||
14 | N-05-14 | Drill Sleeve | 1 | ||||
15 | N-05-15 | Open Wrench | 1 | ||||
16 | N-05-16 | T-handle Wrench | 1 | ||||
17 | N-05-17 | Sleeve | 1 | ||||
18 | N-05-18 | Sleeve | 1 | ||||
19 | N-05-19 | Forcing Cone Short | 1 | ||||
20 | N-05-20 | Sleeve | 1 | ||||
21 | N-05-21 | Forcing Cone Long | 1 | ||||
22 | N-05-22 | Hex Key Large | 1 | ||||
23 | N-05-23 | Hex Key Small | 1 | ||||
24 | N-05-24 | AWL | 1 | ||||
25 | N-05-25 | K-wire Depth Gague | 1 | ||||
26 | N-05-26 | Location Forcep | 1 | ||||
27 | N-05-27 | T-handle Drill Bit | 1 | ||||
28 | N-05-28 | Location Rod | 1 | ||||
29 | N-05-29 | Tap | 1 | ||||
30 | N-05-30 | T-handle Screwdriver | 1 | ||||
31 | N-05-31 | Unversal Joint | 1 | ||||
32 | N-05-32 | Connector Rod | 1 | ||||
33 | N-05-33 | Hammer | 1 | ||||
34 | N-05-34 | Guider Bar | 1 | ||||
35 | N-05-35 | Fixed Connector | 1 | ||||
36 | N-05-36 | Guider Handle | 1 | ||||
37 | N-05-37 | Bolt | 1 | ||||
38 | N-05-38 | Bolt | 1 | ||||
39 | N-05-39 | Quick Coupling T-handle | 1 | ||||
40 | N-05-40 | Bolt | 1 | ||||
41 | N-05-41 | Bolt | 1 | ||||
42 | N-05-42 | Connector | 1 | ||||
43 | N-05-43 | Connector | 1 | ||||
44 | N-05-44 | Connector | 1 | ||||
45 | N-05-45 | Distal Guider | 1 | ||||
46 | N-05-46 | Guider Wire | 1 | ||||
47 | N-05-47 | Aluminium Box | 1 |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Femoral Reconstruction Intramedullary Nail Instrument Set Product Catalog.
2. Choose Your Interested Femoral Reconstruction Intramedullary Nail Instrument Set Product.
3. Ask For A Sample To Test Femoral Reconstruction Intramedullary Nail Instrument Set Quality.
4.Make An Order Of Xc Medico's Femoral Reconstruction Intramedullary Nail Instrument Set.
5.Become A Dealer Of Xc Medico's Femoral Reconstruction Intramedullary Nail Instrument Set.
1. Better Purchase Prices Of Femoral Reconstruction Intramedullary Nail Instrument Set.
2.100% The Highest Quality Femoral Reconstruction Intramedullary Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Femoral Reconstruction Intramedullary Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's Femoral Reconstruction Intramedullary Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Femoral reconstruction intramedullary nail instrument set is a specialized surgical toolkit designed to facilitate the insertion and fixation of intramedullary nails into the femur, the thigh bone. These nails are used to treat a variety of femoral fractures, including those resulting from trauma, osteoporosis, or other conditions.
The set includes reamers in various diameters, allowing surgeons to prepare the femoral canal precisely. This ensures a snug fit for the nail, enhancing stability and reducing the risk of implant migration.
Designed for surgeon comfort and control, ergonomic handles and targeting guides assist in accurate placement and locking of the nail, improving procedural efficiency and minimizing surgeon fatigue.
Constructed from surgical-grade stainless steel and titanium, these instruments are durable, biocompatible, and designed to withstand sterilization. These materials reduce the risk of infection and ensure long-lasting reliability.
Locking screws and precision guides included in the set allow for both proximal and distal fixation of the nail, ensuring secure positioning and reducing the risk of rotational instability.
The set allows for smaller incisions, reducing soft tissue trauma and minimizing scarring.
The biomechanical stability of the intramedullary nail enables patients to start weight-bearing activities sooner, facilitating early rehabilitation and reducing the risks associated with prolonged immobility.
The load-sharing design of the intramedullary nail provides excellent support for complex fractures, ensuring alignment and reducing the chance of malunion. This stability is critical in managing high-energy fractures and multi-fragmented fractures.
Suitable for various types of femoral fractures, including subtrochanteric and diaphyseal fractures, this set offers surgeons the flexibility to address a range of clinical situations with high efficacy.
Surgeons must carefully assess the patient’s femoral anatomy and fracture pattern to select the appropriate nail length and diameter. Improper nail sizing can result in malalignment or implant failure.
Maintaining a sterile environment is critical. All instruments must be thoroughly sterilized to prevent post-operative infections, especially since intramedullary nails are implanted deeply within the bone.
Incorrect positioning of the locking screws can lead to instability and potential implant failure. Surgeons should use intraoperative imaging to confirm alignment and nail positioning.
Over-reaming or aggressive handling can compromise the bone structure. A controlled reaming technique is recommended to prepare the canal without weakening the surrounding bone.
The femoral reconstruction intramedullary nail instrument set market will witness significant growth in the coming years due to advancements in orthopedic technology, an aging population, an increase in the number of fractures, and the need for minimally invasive orthopedic surgical solutions. These factors are reshaping the landscape of trauma care and orthopedic surgery, positioning the femoral reconstruction intramedullary nail instrument set as an essential component of fracture management in the coming years.
In conclusion, femoral reconstruction intramedullary nail instrument sets are essential tools for orthopedic surgeons treating tibial fractures. By selecting a high-quality instrument set, surgeons can improve the efficiency, accuracy, and outcomes of their procedures.
Products | Pictures | Details | |||||
Femoral Reconstruction Intramedullary NailInstrument Set (PNRQPG201) | 1 | N-05-01 | Solid Reamer Ø11 | 1 | |||
2 | N-05-02 | Solid Reamer Ø12 | 1 | ||||
3 | N-05-03 | Solid Reamer Ø12.5 | 1 | ||||
4 | N-05-04 | Solid Reamer Ø13 | 1 | ||||
5 | N-05-05 | Solid Reamer Ø10.4 | 1 | ||||
6 | N-05-06 | Drill Bit | 1 | ||||
7 | N-05-07 | Drill Bit With Limitator | 1 | ||||
8 | N-05-08 | Drill Bit | 1 | ||||
9 | N-05-09 | Depth Gague | 1 | ||||
10 | N-05-10 | Location Forcep | 1 | ||||
11 | N-05-11 | Drill Sleeve | 1 | ||||
12 | N-05-12 | Drill Sleeve | 1 | ||||
13 | N-05-13 | Drill Sleeve | 1 | ||||
14 | N-05-14 | Drill Sleeve | 1 | ||||
15 | N-05-15 | Open Wrench | 1 | ||||
16 | N-05-16 | T-handle Wrench | 1 | ||||
17 | N-05-17 | Sleeve | 1 | ||||
18 | N-05-18 | Sleeve | 1 | ||||
19 | N-05-19 | Forcing Cone Short | 1 | ||||
20 | N-05-20 | Sleeve | 1 | ||||
21 | N-05-21 | Forcing Cone Long | 1 | ||||
22 | N-05-22 | Hex Key Large | 1 | ||||
23 | N-05-23 | Hex Key Small | 1 | ||||
24 | N-05-24 | AWL | 1 | ||||
25 | N-05-25 | K-wire Depth Gague | 1 | ||||
26 | N-05-26 | Location Forcep | 1 | ||||
27 | N-05-27 | T-handle Drill Bit | 1 | ||||
28 | N-05-28 | Location Rod | 1 | ||||
29 | N-05-29 | Tap | 1 | ||||
30 | N-05-30 | T-handle Screwdriver | 1 | ||||
31 | N-05-31 | Unversal Joint | 1 | ||||
32 | N-05-32 | Connector Rod | 1 | ||||
33 | N-05-33 | Hammer | 1 | ||||
34 | N-05-34 | Guider Bar | 1 | ||||
35 | N-05-35 | Fixed Connector | 1 | ||||
36 | N-05-36 | Guider Handle | 1 | ||||
37 | N-05-37 | Bolt | 1 | ||||
38 | N-05-38 | Bolt | 1 | ||||
39 | N-05-39 | Quick Coupling T-handle | 1 | ||||
40 | N-05-40 | Bolt | 1 | ||||
41 | N-05-41 | Bolt | 1 | ||||
42 | N-05-42 | Connector | 1 | ||||
43 | N-05-43 | Connector | 1 | ||||
44 | N-05-44 | Connector | 1 | ||||
45 | N-05-45 | Distal Guider | 1 | ||||
46 | N-05-46 | Guider Wire | 1 | ||||
47 | N-05-47 | Aluminium Box | 1 |
CNC preliminary processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Femoral Reconstruction Intramedullary Nail Instrument Set Product Catalog.
2. Choose Your Interested Femoral Reconstruction Intramedullary Nail Instrument Set Product.
3. Ask For A Sample To Test Femoral Reconstruction Intramedullary Nail Instrument Set Quality.
4.Make An Order Of Xc Medico's Femoral Reconstruction Intramedullary Nail Instrument Set.
5.Become A Dealer Of Xc Medico's Femoral Reconstruction Intramedullary Nail Instrument Set.
1. Better Purchase Prices Of Femoral Reconstruction Intramedullary Nail Instrument Set.
2.100% The Highest Quality Femoral Reconstruction Intramedullary Nail Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Femoral Reconstruction Intramedullary Nail Instrument Set.
6. Quick And Easy Assessment Of XC Medico's Femoral Reconstruction Intramedullary Nail Instrument Set.
7. A Globally Recognized Brand - XC medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Femoral reconstruction intramedullary nail instrument set is a specialized surgical toolkit designed to facilitate the insertion and fixation of intramedullary nails into the femur, the thigh bone. These nails are used to treat a variety of femoral fractures, including those resulting from trauma, osteoporosis, or other conditions.
The set includes reamers in various diameters, allowing surgeons to prepare the femoral canal precisely. This ensures a snug fit for the nail, enhancing stability and reducing the risk of implant migration.
Designed for surgeon comfort and control, ergonomic handles and targeting guides assist in accurate placement and locking of the nail, improving procedural efficiency and minimizing surgeon fatigue.
Constructed from surgical-grade stainless steel and titanium, these instruments are durable, biocompatible, and designed to withstand sterilization. These materials reduce the risk of infection and ensure long-lasting reliability.
Locking screws and precision guides included in the set allow for both proximal and distal fixation of the nail, ensuring secure positioning and reducing the risk of rotational instability.
The set allows for smaller incisions, reducing soft tissue trauma and minimizing scarring.
The biomechanical stability of the intramedullary nail enables patients to start weight-bearing activities sooner, facilitating early rehabilitation and reducing the risks associated with prolonged immobility.
The load-sharing design of the intramedullary nail provides excellent support for complex fractures, ensuring alignment and reducing the chance of malunion. This stability is critical in managing high-energy fractures and multi-fragmented fractures.
Suitable for various types of femoral fractures, including subtrochanteric and diaphyseal fractures, this set offers surgeons the flexibility to address a range of clinical situations with high efficacy.
Surgeons must carefully assess the patient’s femoral anatomy and fracture pattern to select the appropriate nail length and diameter. Improper nail sizing can result in malalignment or implant failure.
Maintaining a sterile environment is critical. All instruments must be thoroughly sterilized to prevent post-operative infections, especially since intramedullary nails are implanted deeply within the bone.
Incorrect positioning of the locking screws can lead to instability and potential implant failure. Surgeons should use intraoperative imaging to confirm alignment and nail positioning.
Over-reaming or aggressive handling can compromise the bone structure. A controlled reaming technique is recommended to prepare the canal without weakening the surrounding bone.
The femoral reconstruction intramedullary nail instrument set market will witness significant growth in the coming years due to advancements in orthopedic technology, an aging population, an increase in the number of fractures, and the need for minimally invasive orthopedic surgical solutions. These factors are reshaping the landscape of trauma care and orthopedic surgery, positioning the femoral reconstruction intramedullary nail instrument set as an essential component of fracture management in the coming years.
In conclusion, femoral reconstruction intramedullary nail instrument sets are essential tools for orthopedic surgeons treating tibial fractures. By selecting a high-quality instrument set, surgeons can improve the efficiency, accuracy, and outcomes of their procedures.
Contact