RPT3S
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | Ref | Specification | Screw |
2.4 T-Shaped Locking Plate (3 Holes) | RPT3S243H | 3H | HA2.4 HC2.4 | |
RPT3S245H | 5H | HA2.4 HC2.4 | ||
RPT3S247H | 7H | HA2.4 HC2.4 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.4 T-Shaped Locking Plate (3 Holes) Product Catalog.
2. Choose Your Interested 2.4 T-Shaped Locking Plate (3 Holes) Product.
3. Ask For A Sample To Test 2.4 T-Shaped Locking Plate (3 Holes) Quality.
4.Make An Order Of Xc Medico's 2.4 T-Shaped Locking Plate (3 Holes).
5.Become A Dealer Of Xc Medico's 2.4 T-Shaped Locking Plate (3 Holes).
1.Better Purchase Prices Of 2.4 T-Shaped Locking Plate (3 Holes).
2.100% The Highest Quality 2.4 T-Shaped Locking Plate (3 Holes).
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.4 T-Shaped Locking Plate (3 Holes).
6. Quick And Easy Assessment Of Xc Medico's 2.4 T-Shaped Locking Plate (3 Holes).
7. A Globally Recognized Brand - Xc Medico.
8. Fast Access Time To Xc Medico Sales Team.
9. Additional Quality Test By Xc Medico Team.
10. Track Your Xc Medico Order From Start To Finish.
2.4 T-shaped locking plate (3 holes) is an orthopedic implant designed for stabilizing fractures in small, anatomically complex bones. Its T-shaped structure, combined with three locking holes, provides enhanced fixation and stability in areas with limited surface area, such as hands, feet, and facial bones.
Made from titanium or titanium alloys, providing biocompatibility, strength, and resistance to corrosion.
Allows for secure multi-directional fixation, ensuring stability in compact spaces.
Enables custom screw placement at different angles, ideal for adapting to specific anatomical requirements.
Advanced design and materials may make it more expensive than traditional plates.
Due to its size and design, the 2.4 T-Shaped Locking Plate (3 Holes) may not be suitable for highly comminuted fractures or fractures requiring extreme stability.
The plate is specifically designed for periarticular fractures and may not be suitable for fractures in other anatomical locations.
Distal Radius Fractures
ProximalPhalangeal Fractures
Metacarpal Fractures
Anesthesia: General or regional anesthesia is typically used depending on the fracture location and patient factors.
Incision and Exposure: The surgeon creates a strategic incision to access the fracture site, minimizing soft tissue dissection around the joint.
Fracture Reduction: The surgeon manipulates the bone fragments to achieve proper alignment and bone contact. Techniques like closed reduction (manipulation without direct visualization) or open reduction (direct visualization) may be employed depending on the fracture complexity.
Plate Application and Locking: The 2.4 T-Shaped Locking Plate (3 Holes) is positioned to achieve stable fixation, and locking screws are secured within the dedicated holes on the "T" portion, targeting the specific fracture fragment. Screws along the shaft may also be used for additional stability.
Wound Closure: The incision is meticulously closed with sutures to minimize scarring and promote healing.
2.4 T-shaped locking plate signifies a valuable innovation in addressing periarticular fractures. Its targeted design offers a biomechanically advantageous solution for stabilizing specific fracture fragments, minimizing soft tissue irritation, and potentially facilitating a minimally invasive surgical approach.
2.4 T-locking plates require surgical expertise and have specific limitations, but their advantages in stability, flexibility, and patient comfort are considerable. The future of locking plates is bright, and advances in materials and surgical techniques promise to lead to broader use in orthopedic care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | Ref | Specification | Screw |
2.4 T-Shaped Locking Plate (3 Holes) | RPT3S243H | 3H | HA2.4 HC2.4 | |
RPT3S245H | 5H | HA2.4 HC2.4 | ||
RPT3S247H | 7H | HA2.4 HC2.4 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.4 T-Shaped Locking Plate (3 Holes) Product Catalog.
2. Choose Your Interested 2.4 T-Shaped Locking Plate (3 Holes) Product.
3. Ask For A Sample To Test 2.4 T-Shaped Locking Plate (3 Holes) Quality.
4.Make An Order Of Xc Medico's 2.4 T-Shaped Locking Plate (3 Holes).
5.Become A Dealer Of Xc Medico's 2.4 T-Shaped Locking Plate (3 Holes).
1.Better Purchase Prices Of 2.4 T-Shaped Locking Plate (3 Holes).
2.100% The Highest Quality 2.4 T-Shaped Locking Plate (3 Holes).
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.4 T-Shaped Locking Plate (3 Holes).
6. Quick And Easy Assessment Of Xc Medico's 2.4 T-Shaped Locking Plate (3 Holes).
7. A Globally Recognized Brand - Xc Medico.
8. Fast Access Time To Xc Medico Sales Team.
9. Additional Quality Test By Xc Medico Team.
10. Track Your Xc Medico Order From Start To Finish.
2.4 T-shaped locking plate (3 holes) is an orthopedic implant designed for stabilizing fractures in small, anatomically complex bones. Its T-shaped structure, combined with three locking holes, provides enhanced fixation and stability in areas with limited surface area, such as hands, feet, and facial bones.
Made from titanium or titanium alloys, providing biocompatibility, strength, and resistance to corrosion.
Allows for secure multi-directional fixation, ensuring stability in compact spaces.
Enables custom screw placement at different angles, ideal for adapting to specific anatomical requirements.
Advanced design and materials may make it more expensive than traditional plates.
Due to its size and design, the 2.4 T-Shaped Locking Plate (3 Holes) may not be suitable for highly comminuted fractures or fractures requiring extreme stability.
The plate is specifically designed for periarticular fractures and may not be suitable for fractures in other anatomical locations.
Distal Radius Fractures
ProximalPhalangeal Fractures
Metacarpal Fractures
Anesthesia: General or regional anesthesia is typically used depending on the fracture location and patient factors.
Incision and Exposure: The surgeon creates a strategic incision to access the fracture site, minimizing soft tissue dissection around the joint.
Fracture Reduction: The surgeon manipulates the bone fragments to achieve proper alignment and bone contact. Techniques like closed reduction (manipulation without direct visualization) or open reduction (direct visualization) may be employed depending on the fracture complexity.
Plate Application and Locking: The 2.4 T-Shaped Locking Plate (3 Holes) is positioned to achieve stable fixation, and locking screws are secured within the dedicated holes on the "T" portion, targeting the specific fracture fragment. Screws along the shaft may also be used for additional stability.
Wound Closure: The incision is meticulously closed with sutures to minimize scarring and promote healing.
2.4 T-shaped locking plate signifies a valuable innovation in addressing periarticular fractures. Its targeted design offers a biomechanically advantageous solution for stabilizing specific fracture fragments, minimizing soft tissue irritation, and potentially facilitating a minimally invasive surgical approach.
2.4 T-locking plates require surgical expertise and have specific limitations, but their advantages in stability, flexibility, and patient comfort are considerable. The future of locking plates is bright, and advances in materials and surgical techniques promise to lead to broader use in orthopedic care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.