Lateral Column
Multiple lateral profiles support different distal geometries, shaft lengths and screw platforms.
A coordinated portfolio of lateral and medial plates, locking and non-locking screw platforms, and supporting instruments for distal humerus fixation planning.
Procedure Overview
Distal humerus projects may require lateral, medial or combined plate configurations. XC Medico brings together dedicated locking plate systems and complementary non-locking plates with compatible small-fragment screws and instruments.
The portfolio is organized for professional product comparison and procurement planning. Final implant selection and positioning remain anatomy-, fracture- and surgeon-specific.
For adjacent upper-limb planning, continue to the humeral shaft fracture fixation solution or proximal humerus fracture fixation solution.
System Architecture
Multiple lateral profiles support different distal geometries, shaft lengths and screw platforms.
Dedicated medial locking and reconstruction-style options extend the column-specific portfolio.
Coordinate side, plate family, hole count and screw compatibility when a multi-plate inventory is required.
Implant Portfolio
Portfolio Matrix
| Implant Family | Type | Size Range | Side | Screw Platform |
|---|---|---|---|---|
| Lateral Locking Plate-I | Locking | 4H-12H | L / R | HA & HC 2.7/3.5 |
| Lateral Locking Plate-II | Locking | 4H-12H | L / R | HA & HC 3.5 |
| Medial Locking Plate | Locking | 4H-12H | L / R | HA & HC 2.7/3.5 |
| Locking Plate for Distal Humerus | Locking | 4H-12H | L / R | HA & HC 3.5 |
| Y-shaped Humerus Condylus Plate | Non-locking | 3H-6H | L / R | HA 3.5 / HB 4.0 |
| Distal Humeral ST Plate | Non-locking | 3H-6H | L / R | HA 3.5 / HB 4.0 |
| Lateral Plate (Olecranon Type) | Non-locking | 12H-18H | L / R | HA 3.5 / HB 4.0 |
| Medial Plate (Reconstruction Type) | Non-locking | 10H-14H | Universal | HA 3.5 / HB 4.0 |
Supporting Components
Coordinate every plate reference with its specified locking screw, cortical or cancellous screw family.
HC 2.7: RSZS27(12-28) · HA 2.7: RST8ZP27(12-24) · HC 3.5: RSZS35(16-50) · HA 3.5: RSP35(14-50) / RSSWP35(12-42) · HB 4.0: RSSWP40(12-50) / RSSWPB40(20-50)The 2.7/3.5 mm small-fragment instrument set supports drilling, guiding, depth measurement, tapping and screw insertion, with an HB 4.0 tap included in the set.
REF: RQBT01 · No implantSystem Value
Coordinate dedicated lateral and medial plate families within one system plan.
Compare locking and non-locking plate principles while keeping each implant, screw and instrument configuration verified.
Compare side, hole count and screw family before confirming the order.
Pair implant and screw configurations with a dedicated small-fragment instrument platform.
Selection Support
Provide these project details so XC Medico can prepare a focused implant, screw and instrument proposal.
B2B Support
Plate, side, size and screw configuration support.
Project-based sample and technical review coordination.
Portfolio, catalog and training-material support.
Discuss packaging, branding and project requirements.
Review XC Medico's orthopedic implant manufacturing and quality control capabilities.
FAQ
The locking portfolio includes Distal Humerus Lateral Locking Plate-I, Lateral Locking Plate-II, Distal Humerus Medial Locking Plate and Locking Plate for Distal Humerus.
Yes. All four locking families and three of the four non-locking families on this page include left and right options. The Medial Plate (Reconstruction Type) is listed by hole count without a side designation.
Depending on the plate family, the locking systems use HA and HC 2.7/3.5 screws or HA and HC 3.5 screws. Compatibility must be matched to the exact plate reference.
The non-locking range includes the Y-shaped Humerus Condylus Plate, Distal Humeral ST Plate, Distal Humeral Lateral Plate (Olecranon Type) and Distal Humeral Medial Plate (Reconstruction Type).
Yes. XC Medico can coordinate selected plate references, compatible screw families and the required small-fragment instrument platform for professional evaluation and procurement projects.
No. It is a system-planning overview for professional users. Surgical use must follow the current IFU, approved labeling, local requirements and the treating surgeon's judgment.
Send the target plate configuration, side, hole counts, screw requirements, instrument needs, destination market and estimated quantity.
Contact