RPTS
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | Ref | Specification | Screw |
2.7 T-Shaped Locking Plate | RPTS273H | 3H | HA2.7 HC2.7 | |
RPTS274H | 4H | HA2.7 HC2.7 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.7 T-Shaped Locking Plate Product Catalog.
2. Choose Your Interested 2.7 T-Shaped Locking Plate Product.
3. Ask For A Sample To Test 2.7 T-Shaped Locking Plate.
4.Make An Order Of XC Medico's 2.7 T-Shaped Locking Plate.
5.Become A Dealer Of XC Medico's 2.7 T-Shaped Locking Plate.
1.Better Purchase Prices Of 2.7 T-Shaped Locking Plate.
2.100% The Highest Quality 2.7 T-Shaped Locking Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.7 T-Shaped Locking Plate.
6. Quick And Easy Assessment Of XC Medico's 2.7 T-Shaped Locking Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.7 T-Shaped Locking Plate is a low-profile, anatomically contoured implant designed for use in fractures involving small bones with complex geometry, such as the distal radius or metatarsals. Its locking mechanism ensures enhanced construct stability.
The plate accommodates both locking and non-locking screws, allowing for hybrid fixation techniques based on fracture patterns.
The broad distal portion of the plate offers multiple screw options, ensuring secure fixation in the metaphyseal region and facilitating anatomical restoration.
Its unique shape and adaptability make it ideal for fractures in areas with limited space and complex anatomy.
As a relatively new technology, the 2.7 T-Shaped Locking Plate may not be available in a wide range of sizes and configurations to accommodate all periarticular fracture variations.
The plate is not suitable for fractures in larger bones or in highly comminuted fractures requiring extensive fixation.
Distal Radius Fractures
Metacarpal and Metatarsal Fractures
Small Bone Metaphyseal Fractures
Anesthesia: General or regional anesthesia is administered to ensure patient comfort during the surgery.
Incision: A small, strategically placed incision is made to minimize soft tissue disruption around the joint. Precise dissection techniques are employed to carefully expose the fracture site while preserving surrounding vital structures, such as nerves and blood vessels.
Fracture Reduction: The fractured bone fragments are meticulously manipulated and reduced to their anatomical position using specialized instruments. This ensures proper alignment and joint congruency for optimal healing.
Plate Positioning: The chosen 2.7 T-Shaped Locking Plate is positioned on the bone surface, ensuring proper alignment with the fracture and anatomical fit around the joint. The T-shaped design allows for targeted screw placement across the fracture site and into the joint fragment for enhanced stability.
Screw Fixation: Locking screws are inserted through the plate and into the bone to achieve optimal fracture reduction and stability. The angled screw holes on the T-head of the plate facilitate targeted screw placement across the fracture for additional support. Cortex screws may be used for additional fixation and compression at the fracture site.
Fluoroscopy Confirmation: Fluoroscopy (real-time X-ray imaging) may be used throughout the procedure to confirm proper plate positioning, screw placement, and fracture reduction.
With an increase in traumatic injuries and sports-related fractures, demand for anatomically specific implants like the T-shaped plate is growing.
Future developments may include 3D-printed implants and bioactive coatings to promote osseointegration and enhance healing.
Emerging markets with improving healthcare infrastructure are expected to drive demand for advanced orthopedic implants.
2.7 T-Shaped Locking Plate is a versatile and innovative implant tailored for the fixation of fractures in small and irregularly shaped bones. Its T-shaped configuration, locking technology, and low-profile design offer precise and stable fixation while minimizing complications. As technology and surgical techniques evolve, this implant will remain an essential tool in the orthopedic surgeon’s arsenal, ensuring better outcomes for patients worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | Ref | Specification | Screw |
2.7 T-Shaped Locking Plate | RPTS273H | 3H | HA2.7 HC2.7 | |
RPTS274H | 4H | HA2.7 HC2.7 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.7 T-Shaped Locking Plate Product Catalog.
2. Choose Your Interested 2.7 T-Shaped Locking Plate Product.
3. Ask For A Sample To Test 2.7 T-Shaped Locking Plate.
4.Make An Order Of XC Medico's 2.7 T-Shaped Locking Plate.
5.Become A Dealer Of XC Medico's 2.7 T-Shaped Locking Plate.
1.Better Purchase Prices Of 2.7 T-Shaped Locking Plate.
2.100% The Highest Quality 2.7 T-Shaped Locking Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.7 T-Shaped Locking Plate.
6. Quick And Easy Assessment Of XC Medico's 2.7 T-Shaped Locking Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.7 T-Shaped Locking Plate is a low-profile, anatomically contoured implant designed for use in fractures involving small bones with complex geometry, such as the distal radius or metatarsals. Its locking mechanism ensures enhanced construct stability.
The plate accommodates both locking and non-locking screws, allowing for hybrid fixation techniques based on fracture patterns.
The broad distal portion of the plate offers multiple screw options, ensuring secure fixation in the metaphyseal region and facilitating anatomical restoration.
Its unique shape and adaptability make it ideal for fractures in areas with limited space and complex anatomy.
As a relatively new technology, the 2.7 T-Shaped Locking Plate may not be available in a wide range of sizes and configurations to accommodate all periarticular fracture variations.
The plate is not suitable for fractures in larger bones or in highly comminuted fractures requiring extensive fixation.
Distal Radius Fractures
Metacarpal and Metatarsal Fractures
Small Bone Metaphyseal Fractures
Anesthesia: General or regional anesthesia is administered to ensure patient comfort during the surgery.
Incision: A small, strategically placed incision is made to minimize soft tissue disruption around the joint. Precise dissection techniques are employed to carefully expose the fracture site while preserving surrounding vital structures, such as nerves and blood vessels.
Fracture Reduction: The fractured bone fragments are meticulously manipulated and reduced to their anatomical position using specialized instruments. This ensures proper alignment and joint congruency for optimal healing.
Plate Positioning: The chosen 2.7 T-Shaped Locking Plate is positioned on the bone surface, ensuring proper alignment with the fracture and anatomical fit around the joint. The T-shaped design allows for targeted screw placement across the fracture site and into the joint fragment for enhanced stability.
Screw Fixation: Locking screws are inserted through the plate and into the bone to achieve optimal fracture reduction and stability. The angled screw holes on the T-head of the plate facilitate targeted screw placement across the fracture for additional support. Cortex screws may be used for additional fixation and compression at the fracture site.
Fluoroscopy Confirmation: Fluoroscopy (real-time X-ray imaging) may be used throughout the procedure to confirm proper plate positioning, screw placement, and fracture reduction.
With an increase in traumatic injuries and sports-related fractures, demand for anatomically specific implants like the T-shaped plate is growing.
Future developments may include 3D-printed implants and bioactive coatings to promote osseointegration and enhance healing.
Emerging markets with improving healthcare infrastructure are expected to drive demand for advanced orthopedic implants.
2.7 T-Shaped Locking Plate is a versatile and innovative implant tailored for the fixation of fractures in small and irregularly shaped bones. Its T-shaped configuration, locking technology, and low-profile design offer precise and stable fixation while minimizing complications. As technology and surgical techniques evolve, this implant will remain an essential tool in the orthopedic surgeon’s arsenal, ensuring better outcomes for patients worldwide.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact