You are here: Home » Products » Trauma System » No-Locking Plate » No-Locking Large Fragment » Curved Anterior Column Plate

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Curved Anterior Column Plate

  • RPWQZ

  • XCmedico

  • 1 Pcs(72 Hours Delivery)

  • Titanium  Alloy

  • CE/ISO:9001/ISO13485.Etc

  • Custom-Made 15 Days Delivery(Excluding Shipping Time)

  • FedEx. DHL.TNT.EMS.Etc

Availability:
Quantity:

Curved Anterior Column Plate Video


Curved Anterior Column Plate PDF

        

Curved Anterior Column Plate Specification

Product Pic Screw REF. Spec.
Curved Anterior Column Plate Curved Anterior Column Plate HB 4.0 RPWQZL L
RPWQZR R



Advantages of  XC Medico's Products

Initial product processing

      CNC Preliminary Processing


The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans.


Polishing products

           Product Polishing




The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant.

Quality Inspection

          Quality Inspection



The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability.

Product package

          Product Package


Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety.

Productwarehouse        Product  Warehouse


The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment.

sample room           Sample Room


The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training.



The Process To Cooperate With XC Medico 

1. Ask Xc Medico Team For Curved Anterior Column Plate Product Catalog.


2. Choose Your Interested Curved Anterior Column Plate Product.


3. Ask For A Sample To Test Posterior Curved Anterior Column Plate.


4.Make An Order Of XC Medico's Posterior Curved Anterior Column Plate.


5.Become A Dealer Of XC Medico's Posterior Curved Anterior Column Plate.



The Advantages To Be A Dealer Or Wholesaler Of  XC Medico

1.Better Purchase Prices Of Posterior Curved Anterior Column Plate.


2.100% The Highest Quality Posterior Curved Anterior Column Plate.


3. Less Ordering Efforts.


4. Price Stability For The Period Of Agreement.


5. Sufficient Posterior Curved Anterior Column Plate.


6. Quick And Easy Assessment Of XC Medico's Posterior Curved Anterior Column Plate.


7. A Globally Recognized Brand - XC Medico.


8. Fast Access Time To XC Medico Sales Team.


9. Additional Quality Test By XC Medico Team.


10. Track Your XC Medico Order From Start To Finish.



Curved Anterior Column Plate: A Comprehensive Guide

The Curved Anterior Column Plate is an advanced orthopedic implant designed to provide secure stabilization for fractures involving the anterior column of the pelvis or other curved anatomical regions. Its unique curved design, tailored for the anatomical structure of the anterior column, ensures precise fixation and effective healing of complex fractures. This comprehensive guide will delve into the features, benefits, treatment applications, risks, and future prospects of the Curved Anterior Column Plate.



What is Curved Anterior Column Plate

The Curved Anterior Column Plate is a specialized implant used in orthopedic surgery to treat fractures of the anterior column of the acetabulum and similar curved bone structures. This region is critical for maintaining pelvic stability and supporting the load-bearing function of the lower limbs. Fractures in this area, often caused by high-impact trauma, require precise alignment and stable fixation to restore function and prevent long-term complications.


The plate's curved design is specifically engineered to follow the natural contours of the anterior column, providing optimal support while minimizing disruption to surrounding soft tissues. Constructed from high-strength materials such as titanium or stainless steel, the Curved Anterior Column Plate ensures durability, biocompatibility, and resistance to corrosion, making it suitable for long-term implantation.



Curved Anterior Column Plate Features

Curved Anatomical Design

The plate is pre-contoured to match the natural curvature of the anterior column, reducing the need for intraoperative adjustments and ensuring a precise fit.

Multiple Screw Holes

Strategically placed screw holes allow for versatile screw placement, accommodating various fracture patterns and anatomical variations.

Locking and Non-locking Screw Compatibility

The plate supports both locking and non-locking screws, providing surgeons with flexibility in achieving optimal fixation for different bone qualities.

Low Profile Construction

The slim profile minimizes soft tissue irritation and reduces the risk of post-operative discomfort or complications.

Durable Material Composition

Made from titanium or stainless steel, the plate is lightweight yet strong, ensuring mechanical stability and biocompatibility.

Radiolucent-friendly Design

Its minimal interference with imaging allows for clear postoperative monitoring through X-rays or CT scans.

Customizable Lengths

Available in various lengths and sizes to suit different patient anatomies and fracture complexities.



Curved Anterior Column Plate Advantages

Enhanced Anatomical Fit

The curved design closely aligns with the natural contour of the anterior column, providing precise stabilization and reducing the need for extensive intraoperative bending.

Improved Fracture Stability

The plate's locking screw compatibility ensures secure fixation, even in osteoporotic or weakened bone, minimizing the risk of implant failure or fracture displacement.

Minimized Soft Tissue Disruption

The low-profile design reduces the risk of irritation to surrounding soft tissues, leading to quicker recovery and reduced post-operative discomfort.

Versatility in Applications

Suitable for a wide range of fractures, the plate is effective in treating complex, comminuted, or intra-articular fractures that require stable and precise fixation.

Optimized Healing Environment

By maintaining proper alignment and stability, the plate supports natural bone healing, reducing the risk of malunion or non-union.

Durable and Long-lasting

Constructed from high-strength, biocompatible materials, the plate ensures long-term reliability and resistance to mechanical stress.

Facilitates Early Mobilization

The robust fixation provided by the plate enables early weight-bearing and mobility, promoting faster rehabilitation and improved functional outcomes.



Curved Anterior Column Plate Treatment of Fracture Types

Anterior Column Acetabular Fractures

These fractures involve the curved anterior column of the acetabulum and require precise alignment to restore joint function and prevent long-term complications such as arthritis.

Pelvic Ring Fractures

Complex fractures of the pelvic ring often involve the anterior column. The plate provides stable fixation, maintaining overall pelvic integrity.

Comminuted Fractures

For fractures with multiple bone fragments, the plate’s multiple screw holes allow for secure fixation of all fragments, ensuring proper alignment and stability.

Intra-articular Fractures

When fractures extend into the joint, the plate helps restore joint congruity, reducing the risk of dysfunction or chronic pain.

Osteoporotic Fractures

In elderly patients with low bone density, the locking screw mechanism provides enhanced fixation, reducing the likelihood of implant failure.

Fracture-dislocations

The plate can be used to stabilize fractures combined with joint dislocations, ensuring proper alignment and restoring joint function.



Risks of Curved Anterior Column Plate Surgery

Infection

Post-operative infections are a potential risk, especially in cases involving open fractures or complex surgical procedures.

Non-union or Malunion

Despite robust fixation, improper alignment or patient-related factors may lead to non-union (failure of the bone to heal) or malunion (incorrect healing).

Implant Failure

Excessive mechanical stress or premature weight-bearing can result in implant failure, necessitating revision surgery.

Nerve or Vascular Injury

The surgical area's proximity to major nerves and blood vessels increases the risk of accidental injury during implantation.

Soft Tissue Irritation

Although designed to minimize irritation, some patients may experience discomfort or inflammation around the implant site.

Hardware Loosening

Over time, screws may loosen, particularly in patients with poor bone quality or inadequate post-operative care.



Curved Anterior Column Plate Future Marke

Rising Trauma Cases

The increasing prevalence of high-energy trauma injuries globally is boosting demand for advanced orthopedic implants like the Curved Anterior Column Plate.

Aging Population

With an aging population prone to osteoporotic fractures, the need for durable and effective fixation solutions is expected to grow.

Advancements in Implant Technology

Innovations in materials and manufacturing techniques, such as 3D printing and bioresorbable implants, are likely to enhance the functionality and appeal of the Curved Anterior Column Plate.

Expanding Healthcare Access

Improvements in healthcare infrastructure, particularly in developing regions, are increasing access to advanced orthopedic treatments, driving market growth.

Minimally Invasive Surgery Trends

The trend toward minimally invasive surgical techniques is expected to increase the adoption of low-profile, anatomically contoured implants like the Curved Anterior Column Plate.



Summary

The Curved Anterior Column Plate is an essential implant for the stabilization and healing of complex fractures involving the anterior column of the acetabulum and other curved anatomical regions. With features such as anatomical contouring, locking screw compatibility, and durable material composition, the plate offers precise fixation, reduced soft tissue disruption, and improved patient outcomes. While risks such as infection and implant failure exist, they can be mitigated through proper surgical technique and post-operative care.


As advancements in orthopedic technology continue and the demand for effective fracture solutions grows, the Curved Anterior Column Plate is poised to remain a cornerstone in fracture management, providing reliable and long-lasting results for patients worldwide.


Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.

Previous: 
Next: 

Contact With Us Now!

We have an extremely strict delivery process,from sample approval to final product delivery, and then to shipment confirmation, which allow us more close to your accurate demand and requirement.
XC Medico is leading orthopedic implants and instruments distributor and manufacturer in China. We provide trauma systems, spine systems, CMF/maxillofacial systems, sport medicine systems, joint systems, external fixator systems, orthopedic instruments, and medical power tools.

Quick Links

Contact

Tianan Cyber City, Changwu Middle Road, Changzhou, China
86-18961187889

Keep In Touch

To know more about XC Medico, please subscribe our Youtube channel, or follow us on Linkedin or Facebook. We’ll keep updating our information for you.
© COPYRIGHT 2024 CHANGZHOU XC MEDICO TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.