RQDS01
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Products | Pictures | Details | |||
DHS & DCS Plate Instrument Set(PN:RQDS01) | 1 | T-handle Quick Coupling | 1 | ||
2 | Tap Cortical 4.5mm | 1 | |||
3 | Double Drill Sleeve (Φ4.5/Φ6.5) | 1 | |||
4 | Double Drill Sleeve(Φ4.5/Φ3.2) | 1 | |||
5 | Neutral and Load Drill Guide Φ2.5 | 1 | |||
6 | Tap Cancellous 6.5mm | 1 | |||
7 | Drill Bit Φ4.5* 150mm | 2 | |||
8 | Drill Bit Φ3.2* 150mm | 2 | |||
9 | Lag Screw Depth Measuring Device | 1 | |||
10 | Tap Cancellous 12mm | 1 | |||
11 | Threaded K-wire Φ2.5*225mm | 3 | |||
12 | DHS/DCS Impactor Large | 1 | |||
13 | Depth Gauge(0- 100mm) | 1 | |||
14 | DHS/DCS Impactor Small | 1 | |||
15 | DHS/DCS Wrench, Purple Sleeve | 1 | |||
16 | DHS/DCS Wrench, Golden Sleeve | 1 | |||
17 | Screwdriver Hexagonal 3.5mm | 1 | |||
18 | DCS Angle Guide 95 Degree | 1 | |||
19 | DHS Angle Guier 135 degree | 1 | |||
20 | DHS Reamer | 1 | |||
21 | DCS Reamer | 1 | |||
22 | Aluminium Box | 1 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For DHS & DCS Plate Instrument Set Product Catalog.
2. Choose Your Interested DHS & DCS Plate Instrument Set Product.
3. Ask For A Sample To Test DHS & DCS Plate Instrument Set.
4.Make An Order Of XC Medico's DHS & DCS Plate Instrument Set.
5.Become A Dealer Of XC Medico's DHS & DCS Plate Instrument Set.
1.Better Purchase Prices Of DHS & DCS Plate Instrument Set.
2.100% The Highest Quality DHS & DCS Plate Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient DHS & DCS Plate Instrument Set.
6. Quick And Easy Assessment Of XC Medico's DHS & DCS Plate Instrument Set.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The Dynamic Hip Screw (DHS) & Dynamic Condylar Screw (DCS) Plate Instrument Set is a vital toolkit in modern orthopedic surgery, designed to facilitate the fixation of fractures in the proximal femur and distal femur, respectively. These systems are essential for stabilizing complex fractures while ensuring proper anatomical alignment and early mobilization. This guide provides a detailed overview of the DHS & DCS Plate Instrument Set, highlighting its features, advantages, clinical applications, associated risks, and market outlook.
The DHS & DCS Plate Instrument Set is a specialized collection of surgical instruments used for the implantation of Dynamic Hip Screw (DHS) and Dynamic Condylar Screw (DCS) systems. These implants are widely used in orthopedic surgery to stabilize fractures of the proximal and distal femur, particularly in high-load-bearing regions.
The DHS system is primarily utilized for stabilizing intertrochanteric and subtrochanteric fractures of the proximal femur. Meanwhile, the DCS system is designed for distal femoral fractures, including those involving the condyles. This instrument set includes tools such as guide wires, reamers, depth gauges, screwdrivers, and plate benders, ensuring precision and efficiency during surgical procedures.
Includes guide wires, cannulated reamers, depth gauges, plate benders, drill bits, and screwdrivers tailored for DHS and DCS systems.
The instruments are organized in a modular tray system, facilitating quick and efficient access during surgery.
All instruments are made from surgical-grade stainless steel for durability, corrosion resistance, and compatibility with sterilization processes.
Some instruments are radiolucent, allowing for real-time imaging during surgery to verify implant placement.
Designed with ergonomics in mind, the instruments provide a comfortable grip, reducing hand fatigue during lengthy procedures.
Instruments like angled guides and aiming devices ensure accurate alignment of screws and plates, critical for achieving optimal fixation.
The set accommodates a range of plate lengths and screw sizes, allowing customization based on fracture type and patient anatomy.
The specialized tools enable accurate placement of screws and plates, minimizing the risk of malalignment or implant failure.
The set supports the treatment of a wide range of femoral fractures, making it a versatile choice for trauma and reconstructive surgeries.
The organized and efficient nature of the instrument set streamlines surgical workflows, reducing operative time and associated risks.
DHS and DCS systems provide dynamic compression, ensuring stable fixation and promoting faster fracture healing.
The set supports minimally invasive techniques, reducing trauma to surrounding tissues and enhancing post-operative recovery.
High-quality materials ensure long-term usability, making the set a cost-effective investment for healthcare facilities.
Proper fixation and early mobilization reduce complications such as nonunion and enable patients to regain mobility faster.
DHS systems provide stable fixation for fractures in the proximal femur, restoring load-bearing capacity.
The set facilitates accurate placement of implants for complex fractures extending below the lesser trochanter.
DCS systems are ideal for stabilizing fractures involving the condyles, ensuring proper alignment and joint function.
The set allows for secure stabilization of multi-fragmentary fractures, promoting effective healing.
The instrument set supports the fixation of fractures occurring around existing implants, such as hip or knee prostheses.
Used in cases of fractures caused by bone diseases like osteoporosis or metastatic tumors, providing reliable stabilization.
As with any surgical procedure, there is a risk of infection at the surgical site or around the implant.
Improper placement or excessive stress on the implants may lead to loosening, breakage, or loss of fixation.
Inaccurate placement of screws or plates can result in poor fracture alignment, potentially requiring revision surgery.
Excessive manipulation during surgery may lead to injury to surrounding nerves, blood vessels, or muscles.
In some cases, fractures may fail to heal promptly, necessitating further intervention.
Prolonged surgeries may increase the risk of complications related to anesthesia, particularly in elderly or high-risk patients.
Surgeons inexperienced with the instrument set may require additional training to achieve optimal results.
Increasing road accidents, sports injuries, and falls are driving demand for advanced orthopedic solutions.
The global rise in elderly populations, prone to hip and femoral fractures, is fueling the need for DHS and DCS systems.
Innovations in implant design and surgical techniques are enhancing the adoption of these instrument sets.
Improved healthcare infrastructure and access to surgical care in developing regions are expected to boost market growth.
The growing demand for less invasive procedures is increasing the use of precision-oriented instrument sets.
Ongoing approvals and certifications of new designs and materials are expanding the availability of DHS and DCS systems worldwide.
The DHS & DCS Plate Instrument Set is an indispensable toolkit in orthopedic trauma surgery, providing the precision and reliability required for managing complex femoral fractures. Its advanced features, ergonomic design, and compatibility with various surgical techniques make it a critical asset for surgeons. While associated risks exist, adherence to surgical protocols and proper training can minimize complications. As the demand for advanced fracture fixation solutions continues to grow, the DHS & DCS Plate Instrument Set remains a cornerstone in orthopedic care, offering improved patient outcomes and driving advancements in the field.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Products | Pictures | Details | |||
DHS & DCS Plate Instrument Set(PN:RQDS01) | 1 | T-handle Quick Coupling | 1 | ||
2 | Tap Cortical 4.5mm | 1 | |||
3 | Double Drill Sleeve (Φ4.5/Φ6.5) | 1 | |||
4 | Double Drill Sleeve(Φ4.5/Φ3.2) | 1 | |||
5 | Neutral and Load Drill Guide Φ2.5 | 1 | |||
6 | Tap Cancellous 6.5mm | 1 | |||
7 | Drill Bit Φ4.5* 150mm | 2 | |||
8 | Drill Bit Φ3.2* 150mm | 2 | |||
9 | Lag Screw Depth Measuring Device | 1 | |||
10 | Tap Cancellous 12mm | 1 | |||
11 | Threaded K-wire Φ2.5*225mm | 3 | |||
12 | DHS/DCS Impactor Large | 1 | |||
13 | Depth Gauge(0- 100mm) | 1 | |||
14 | DHS/DCS Impactor Small | 1 | |||
15 | DHS/DCS Wrench, Purple Sleeve | 1 | |||
16 | DHS/DCS Wrench, Golden Sleeve | 1 | |||
17 | Screwdriver Hexagonal 3.5mm | 1 | |||
18 | DCS Angle Guide 95 Degree | 1 | |||
19 | DHS Angle Guier 135 degree | 1 | |||
20 | DHS Reamer | 1 | |||
21 | DCS Reamer | 1 | |||
22 | Aluminium Box | 1 |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For DHS & DCS Plate Instrument Set Product Catalog.
2. Choose Your Interested DHS & DCS Plate Instrument Set Product.
3. Ask For A Sample To Test DHS & DCS Plate Instrument Set.
4.Make An Order Of XC Medico's DHS & DCS Plate Instrument Set.
5.Become A Dealer Of XC Medico's DHS & DCS Plate Instrument Set.
1.Better Purchase Prices Of DHS & DCS Plate Instrument Set.
2.100% The Highest Quality DHS & DCS Plate Instrument Set.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient DHS & DCS Plate Instrument Set.
6. Quick And Easy Assessment Of XC Medico's DHS & DCS Plate Instrument Set.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The Dynamic Hip Screw (DHS) & Dynamic Condylar Screw (DCS) Plate Instrument Set is a vital toolkit in modern orthopedic surgery, designed to facilitate the fixation of fractures in the proximal femur and distal femur, respectively. These systems are essential for stabilizing complex fractures while ensuring proper anatomical alignment and early mobilization. This guide provides a detailed overview of the DHS & DCS Plate Instrument Set, highlighting its features, advantages, clinical applications, associated risks, and market outlook.
The DHS & DCS Plate Instrument Set is a specialized collection of surgical instruments used for the implantation of Dynamic Hip Screw (DHS) and Dynamic Condylar Screw (DCS) systems. These implants are widely used in orthopedic surgery to stabilize fractures of the proximal and distal femur, particularly in high-load-bearing regions.
The DHS system is primarily utilized for stabilizing intertrochanteric and subtrochanteric fractures of the proximal femur. Meanwhile, the DCS system is designed for distal femoral fractures, including those involving the condyles. This instrument set includes tools such as guide wires, reamers, depth gauges, screwdrivers, and plate benders, ensuring precision and efficiency during surgical procedures.
Includes guide wires, cannulated reamers, depth gauges, plate benders, drill bits, and screwdrivers tailored for DHS and DCS systems.
The instruments are organized in a modular tray system, facilitating quick and efficient access during surgery.
All instruments are made from surgical-grade stainless steel for durability, corrosion resistance, and compatibility with sterilization processes.
Some instruments are radiolucent, allowing for real-time imaging during surgery to verify implant placement.
Designed with ergonomics in mind, the instruments provide a comfortable grip, reducing hand fatigue during lengthy procedures.
Instruments like angled guides and aiming devices ensure accurate alignment of screws and plates, critical for achieving optimal fixation.
The set accommodates a range of plate lengths and screw sizes, allowing customization based on fracture type and patient anatomy.
The specialized tools enable accurate placement of screws and plates, minimizing the risk of malalignment or implant failure.
The set supports the treatment of a wide range of femoral fractures, making it a versatile choice for trauma and reconstructive surgeries.
The organized and efficient nature of the instrument set streamlines surgical workflows, reducing operative time and associated risks.
DHS and DCS systems provide dynamic compression, ensuring stable fixation and promoting faster fracture healing.
The set supports minimally invasive techniques, reducing trauma to surrounding tissues and enhancing post-operative recovery.
High-quality materials ensure long-term usability, making the set a cost-effective investment for healthcare facilities.
Proper fixation and early mobilization reduce complications such as nonunion and enable patients to regain mobility faster.
DHS systems provide stable fixation for fractures in the proximal femur, restoring load-bearing capacity.
The set facilitates accurate placement of implants for complex fractures extending below the lesser trochanter.
DCS systems are ideal for stabilizing fractures involving the condyles, ensuring proper alignment and joint function.
The set allows for secure stabilization of multi-fragmentary fractures, promoting effective healing.
The instrument set supports the fixation of fractures occurring around existing implants, such as hip or knee prostheses.
Used in cases of fractures caused by bone diseases like osteoporosis or metastatic tumors, providing reliable stabilization.
As with any surgical procedure, there is a risk of infection at the surgical site or around the implant.
Improper placement or excessive stress on the implants may lead to loosening, breakage, or loss of fixation.
Inaccurate placement of screws or plates can result in poor fracture alignment, potentially requiring revision surgery.
Excessive manipulation during surgery may lead to injury to surrounding nerves, blood vessels, or muscles.
In some cases, fractures may fail to heal promptly, necessitating further intervention.
Prolonged surgeries may increase the risk of complications related to anesthesia, particularly in elderly or high-risk patients.
Surgeons inexperienced with the instrument set may require additional training to achieve optimal results.
Increasing road accidents, sports injuries, and falls are driving demand for advanced orthopedic solutions.
The global rise in elderly populations, prone to hip and femoral fractures, is fueling the need for DHS and DCS systems.
Innovations in implant design and surgical techniques are enhancing the adoption of these instrument sets.
Improved healthcare infrastructure and access to surgical care in developing regions are expected to boost market growth.
The growing demand for less invasive procedures is increasing the use of precision-oriented instrument sets.
Ongoing approvals and certifications of new designs and materials are expanding the availability of DHS and DCS systems worldwide.
The DHS & DCS Plate Instrument Set is an indispensable toolkit in orthopedic trauma surgery, providing the precision and reliability required for managing complex femoral fractures. Its advanced features, ergonomic design, and compatibility with various surgical techniques make it a critical asset for surgeons. While associated risks exist, adherence to surgical protocols and proper training can minimize complications. As the demand for advanced fracture fixation solutions continues to grow, the DHS & DCS Plate Instrument Set remains a cornerstone in orthopedic care, offering improved patient outcomes and driving advancements in the field.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact