RP2HS
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Locking 110°L-Plate | ![]() ![]() | RP2HS421XL3 | 4 holes, 1.0mm, 21mm |
RP2HS527XL3 | 5 holes, 1.0mm, 27mm | ||
RP2HS735XL3 | 7 holes, 1.0mm, 35mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Locking 110°L-Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Locking 110°L-Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Locking 110°L-Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Locking 110°L-Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Locking 110°L-Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Locking 110°L-Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Locking 110°L-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Locking 110°L-Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Locking 110°L-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Maxillofacial injuries require precise treatment to restore both function and aesthetics. The 2.0 Maxillofacial Mini Locking 110° L-Plate is an advanced orthopedic implant designed to address complex facial fractures. This guide provides an in-depth analysis of this innovative device, its features, benefits, applications, risks, and market potential.
The 2.0 Maxillofacial Mini Locking 110° L-Plate is a specialized implant engineered for the stabilization of fractures in the maxillofacial region. Its unique 110° angular design is tailored to fit complex anatomical structures, ensuring optimal fixation and alignment of facial bones during the healing process. This device is ideal for treating a wide range of maxillofacial fractures, including those involving the mandible, maxilla, and zygomatic bones.
The locking screws ensure secure fixation, reducing the risk of screw loosening and plate migration.
The plate's unique angular design accommodates intricate anatomical regions for optimal alignment.
Manufactured from titanium or titanium alloys, the plate offers excellent biocompatibility and resistance to corrosion.
Minimizes soft tissue irritation and improves patient comfort postoperatively.
Reduces the need for extensive intraoperative adjustments, saving surgical time.
Enables clear imaging for postoperative evaluations.
The locking mechanism ensures rigid fixation even under dynamic loads.
The pre-contoured plate design streamlines the surgical process.
Optimal stabilization promotes efficient bone regeneration and lowers the risk of complications.
Suitable for various fracture types, including simple, comminuted, and pediatric cases.
The low-profile design minimizes postoperative discomfort and eliminates the need for additional surgeries to remove the implant.
Ideal for stabilizing fractures in the mandibular angle and symphysis regions.
Provides effective fixation for fractures involving the zygomatic arch and maxilla.
Offers precise stabilization for orbital floor and rim fractures.
Well-suited for treating complex Le Fort I, II, and III fracture patterns.
Its compact and adaptable design makes it suitable for treating fractures in children.
As with any surgical procedure, there is a risk of infection at the surgical site.
Although rare, improper placement or excessive biomechanical stress can result in hardware complications.
Despite the low-profile design, minor irritation may occur in some cases.
General or local anesthesia carries inherent risks during surgery.
Extended fixation may lead to localized bone thinning around the implant.
Innovations in materials and design enhance performance and broaden applications.
Rising cases of road accidents and sports injuries drive demand for reliable implants.
Emerging markets offer significant growth opportunities for advanced surgical devices.
The demand for precise, effective implants increases as reconstructive and cosmetic surgeries gain traction.
Research into bioresorbable materials may shape the future of maxillofacial implants.
The 2.0 Maxillofacial Mini Locking 110° L-Plate represents a remarkable advancement in the field of maxillofacial surgery. Its unique design, coupled with robust features and benefits, ensures superior outcomes for both patients and surgeons. Although associated with some risks, its advantages significantly outweigh the drawbacks, making it a reliable and versatile option in treating facial fractures. As market trends and technology continue to evolve, the future of this implant holds great promise for innovation and enhanced patient care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Locking 110°L-Plate | ![]() ![]() | RP2HS421XL3 | 4 holes, 1.0mm, 21mm |
RP2HS527XL3 | 5 holes, 1.0mm, 27mm | ||
RP2HS735XL3 | 7 holes, 1.0mm, 35mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. |
The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. |
The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Locking 110°L-Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Locking 110°L-Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Locking 110°L-Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Locking 110°L-Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Locking 110°L-Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Locking 110°L-Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Locking 110°L-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Locking 110°L-Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Locking 110°L-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
Maxillofacial injuries require precise treatment to restore both function and aesthetics. The 2.0 Maxillofacial Mini Locking 110° L-Plate is an advanced orthopedic implant designed to address complex facial fractures. This guide provides an in-depth analysis of this innovative device, its features, benefits, applications, risks, and market potential.
The 2.0 Maxillofacial Mini Locking 110° L-Plate is a specialized implant engineered for the stabilization of fractures in the maxillofacial region. Its unique 110° angular design is tailored to fit complex anatomical structures, ensuring optimal fixation and alignment of facial bones during the healing process. This device is ideal for treating a wide range of maxillofacial fractures, including those involving the mandible, maxilla, and zygomatic bones.
The locking screws ensure secure fixation, reducing the risk of screw loosening and plate migration.
The plate's unique angular design accommodates intricate anatomical regions for optimal alignment.
Manufactured from titanium or titanium alloys, the plate offers excellent biocompatibility and resistance to corrosion.
Minimizes soft tissue irritation and improves patient comfort postoperatively.
Reduces the need for extensive intraoperative adjustments, saving surgical time.
Enables clear imaging for postoperative evaluations.
The locking mechanism ensures rigid fixation even under dynamic loads.
The pre-contoured plate design streamlines the surgical process.
Optimal stabilization promotes efficient bone regeneration and lowers the risk of complications.
Suitable for various fracture types, including simple, comminuted, and pediatric cases.
The low-profile design minimizes postoperative discomfort and eliminates the need for additional surgeries to remove the implant.
Ideal for stabilizing fractures in the mandibular angle and symphysis regions.
Provides effective fixation for fractures involving the zygomatic arch and maxilla.
Offers precise stabilization for orbital floor and rim fractures.
Well-suited for treating complex Le Fort I, II, and III fracture patterns.
Its compact and adaptable design makes it suitable for treating fractures in children.
As with any surgical procedure, there is a risk of infection at the surgical site.
Although rare, improper placement or excessive biomechanical stress can result in hardware complications.
Despite the low-profile design, minor irritation may occur in some cases.
General or local anesthesia carries inherent risks during surgery.
Extended fixation may lead to localized bone thinning around the implant.
Innovations in materials and design enhance performance and broaden applications.
Rising cases of road accidents and sports injuries drive demand for reliable implants.
Emerging markets offer significant growth opportunities for advanced surgical devices.
The demand for precise, effective implants increases as reconstructive and cosmetic surgeries gain traction.
Research into bioresorbable materials may shape the future of maxillofacial implants.
The 2.0 Maxillofacial Mini Locking 110° L-Plate represents a remarkable advancement in the field of maxillofacial surgery. Its unique design, coupled with robust features and benefits, ensures superior outcomes for both patients and surgeons. Although associated with some risks, its advantages significantly outweigh the drawbacks, making it a reliable and versatile option in treating facial fractures. As market trends and technology continue to evolve, the future of this implant holds great promise for innovation and enhanced patient care.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact