You are here: Home » Products » CMF/Maxillofacial System » Maxillofical Locking Plate System » 2.0 Maxillofacial Mini Locking Arc Bridge Plate

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

2.0 Maxillofacial Mini Locking Arc Bridge Plate

  • RP2HS

  • XCmedico

  • 1 Pcs(72 Hours Delivery)

  • Titanium  Alloy

  • CE/ISO:9001/ISO13485.Etc

  • Custom-Made 15 Days Delivery(Excluding Shipping Time)

  • FedEx. DHL.TNT.EMS.Etc

Availability:
Quantity:

2.0 Maxillofacial Mini Locking Arc Bridge Plate Video


2.0 Maxillofacial Mini Locking Arc Bridge Plate PDF

        

2.0 Maxillofacial Mini Locking Arc Bridge Plate Specification

Name Picture Item No. Specification
2.0 Maxillofacial Mini Locking Arc Bridge Plate 2.0 Maxillofacial Mini Locking Arc Bridge Plate RP2HS424HQ3 4 holes, 1.0mm, 24mm



Advantages of  XC Medico's Products

Initial product processing

      CNC Preliminary Processing


The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans.


Polishing products

           Product Polishing




The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant.

Quality Inspection

          Quality Inspection



The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability.

Product package

          Product Package


Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety.

Productwarehouse        Product  Warehouse


The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment.

sample room           Sample Room


The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training.



The Process To Cooperate With XC Medico 

1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Locking Arc Bridge Plate Product Catalog.


2. Choose Your Interested 2.0 Maxillofacial Mini Locking Arc Bridge Plate Product.


3. Ask For A Sample To Test 2.0 Maxillofacial Mini Locking Arc Bridge Plate.


4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Locking Arc Bridge Plate.


5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Locking Arc Bridge Plate.



The Advantages To Be A Dealer Or Wholesaler Of  XC Medico

1.Better Purchase Prices Of 2.0 Maxillofacial Mini Locking Arc Bridge Plate.


2.100% The Highest Quality 2.0 Maxillofacial Mini Locking Arc Bridge Plate.


3. Less Ordering Efforts.


4. Price Stability For The Period Of Agreement.


5. Sufficient 2.0 Maxillofacial Mini Locking Arc Bridge Plate.


6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Locking Arc Bridge Plate.


7. A Globally Recognized Brand - XC Medico.


8. Fast Access Time To XC Medico Sales Team.


9. Additional Quality Test By XC Medico Team.


10. Track Your XC Medico Order From Start To Finish.



2.0 Maxillofacial Mini Locking Arc Bridge Plate : A Comprehensive Guide

Maxillofacial trauma and deformities often require specialized implants to restore the form and function of facial structures. The 2.0 Maxillofacial Mini Locking Arc Bridge Plate is an advanced surgical device designed to provide secure and precise stabilization of fractured facial bones. In this comprehensive guide, we will delve into the design, features, advantages, clinical applications, and potential risks of the 2.0 Maxillofacial Mini Locking Arc Bridge Plate. This detailed exploration aims to provide essential insights for medical professionals, students, and researchers in the field of orthopedic and maxillofacial surgery.



What is 2.0 Maxillofacial Mini Locking Arc Bridge Plate

The 2.0 Maxillofacial Mini Locking Arc Bridge Plate is a specialized implant used in the treatment of maxillofacial fractures. This "2.0" plate refers to its size and design, which are specifically tailored for smaller, delicate facial bones. The "mini" aspect of the plate ensures that it can be used in areas with limited space, such as around the orbital or zygomatic regions, while providing the required mechanical support for bone healing.


The "locking" feature of the plate refers to the locking screws used to secure the plate firmly to the bone. These screws are designed to create a rigid connection between the plate and the bone, minimizing the risk of screw loosening or shifting during the healing process. The "arc bridge" design provides a smooth, contoured shape that can be adapted to the anatomical curves of the facial bones, ensuring optimal alignment and stability.


Typically made from high-strength titanium or stainless steel, the 2.0 Maxillofacial Mini Locking Arc Bridge Plate is both durable and biocompatible, ensuring that it integrates well with the body while reducing the risk of rejection or infection.



2.0 Maxillofacial Mini Locking Arc Bridge Plate Features

Arc Bridge Design

The plate features a curved arc shape, designed to follow the natural contours of the facial skeleton. This design is essential for ensuring a precise fit in the zygomatic, orbital, and mandibular regions, contributing to optimal alignment and support.

Miniature Size

 The "mini" size ensures that the plate is perfect for small or delicate fractures, particularly in pediatric patients or areas with limited space.

Locking Mechanism

The locking screws used with this plate provide a secure attachment to the bone, creating a strong and stable fixation that reduces the chances of screw loosening or failure.

High-Strength Materials

Constructed from biocompatible titanium or stainless steel, the plate offers exceptional strength, corrosion resistance, and compatibility with human tissue.

Pre-Drilled Screw Holes

The plate features multiple screw holes that are pre-drilled for easy insertion and precise fixation. The screw holes are designed to accommodate locking screws that can be inserted at a range of angles for optimal placement.

Malleability

The plate is designed to be easily bent and contoured during surgery to match the patient’s unique anatomical features. This adaptability allows for a customized fit that improves the overall success of the procedure.

Minimal Invasiveness

The compact size of the plate and its precise design allow for minimal surgical trauma, promoting quicker recovery times and reduced scarring.



2.0 Maxillofacial Mini Locking Arc Bridge Plate Advantages

Enhanced Stability

The locking screw mechanism creates a rigid fixation between the plate and the bone, offering superior stability compared to traditional plates. This reduces the risk of plate displacement or screw loosening during the healing phase.

Reduced Risk of Complications

The anatomical arc design provides precise alignment, reducing the chances of complications such as malunion or nonunion of fractured bones. This helps ensure the proper restoration of facial aesthetics and function.

Faster Recovery

The plate's minimal invasiveness and biocompatible materials allow for a faster recovery time, with less tissue damage and reduced postoperative pain.

Versatility

The 2.0 Maxillofacial Mini Locking Arc Bridge Plate is versatile and can be used for a wide range of fractures in the maxillofacial region, including zygomatic fractures, orbital fractures, and mandibular fractures.

Aesthetic Outcomes

The arc bridge design helps maintain facial symmetry by providing precise bone alignment. This is crucial in facial surgeries where both functional and cosmetic outcomes are important.

Long-Term Durability

The high-strength materials used in the plate ensure that it provides long-term durability and resistance to corrosion, making it a reliable option for permanent fixation of fractures.



2.0 Maxillofacial Mini Locking Arc Bridge Plate Treatment of Fracture Types

Zygomatic Fractures

Fractures of the cheekbone (zygoma) are common in trauma cases, and the arc bridge plate provides strong support to stabilize these fractures and restore the facial contour.

Orbital Fractures

The plate is particularly useful for treating fractures of the orbital rim or floor, where precise bone alignment is essential to maintain eye function and prevent vision impairment.

Mandibular Fractures

The plate can be used in the treatment of fractures to the lower jaw (mandible), especially in cases where traditional plates are too large or difficult to apply.

Fractures with Displacement

The locking mechanism of the plate is beneficial for treating displaced fractures, ensuring that bone fragments remain in proper alignment during the healing process.

Complex Facial Fractures:

In cases of complex fractures involving multiple facial bones, the 2.0 Maxillofacial Mini Locking Arc Bridge Plate can be used in combination with other plates and screws to provide comprehensive stabilization.



Risks of 2.0 Maxillofacial Mini Locking Arc Bridge Plate Surgery

Infection

There is always a risk of infection at the surgical site, which can complicate the healing process. Prophylactic antibiotics are typically administered to reduce this risk.

Plate Displacement

While rare, the plate may shift or become displaced, particularly if the bone does not heal as expected. In such cases, revision surgery may be required.

Nerve Damage

Given the proximity of facial nerves, there is a risk of nerve injury during surgery, which can result in sensory or motor deficits.

Nonunion or Malunion

In some cases, the bone may fail to heal correctly, leading to nonunion (failure to heal) or malunion (improper healing), both of which may require additional surgical interventions.

Plate Fracture

In rare cases, the plate itself may fracture due to excessive stress or poor bone healing.

Allergic Reactions

Although titanium and stainless steel are biocompatible, some patients may have allergic reactions to these materials, leading to complications such as inflammation or implant rejection.



2.0 Maxillofacial Mini Locking Arc Bridge Plate Future Marke

Increasing Demand for Facial Trauma Surgeries

With rising incidents of accidents, sports injuries, and violent trauma, the need for reliable implants like the 2.0 Maxillofacial Mini Locking Arc Bridge Plate will continue to grow.

Technological Advancements

As surgical techniques improve and materials evolve, the demand for more advanced, reliable implants will increase. Innovations in 3D printing and personalized implant design may further enhance the precision and effectiveness of devices like the 2.0 Maxillofacial Mini Locking Arc Bridge Plate.

Aging Population

The increasing aging population, with its higher incidence of bone fragility and fractures, will also contribute to the growing need for maxillofacial reconstructive surgeries and implants.

Expanding Healthcare Access

Emerging markets, particularly in Asia, Africa, and Latin America, are likely to see increased demand for high-quality implants as healthcare infrastructure improves.



Summary

The 2.0 Maxillofacial Mini Locking Arc Bridge Plate is a cutting-edge surgical implant designed for the stabilization of fractures in the maxillofacial region. Its unique arc bridge design, coupled with locking screws, ensures a precise and secure fixation, promoting optimal bone healing and reducing the risk of complications. While there are risks such as infection, nerve damage, and plate displacement, the advantages offered by this implant, including enhanced stability, reduced recovery time, and improved aesthetic outcomes, make it an essential tool for maxillofacial surgeons. With the growing demand for facial trauma surgeries and innovations in medical technology, the future of the 2.0 Maxillofacial Mini Locking Arc Bridge Plate looks set for continued success in the global orthopedic and maxillofacial market.


Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.

Previous: 
Next: 

Contact With Us Now!

We have an extremely strict delivery process,from sample approval to final product delivery, and then to shipment confirmation, which allow us more close to your accurate demand and requirement.
XC Medico is leading orthopedic implants and instruments distributor and manufacturer in China. We provide trauma systems, spine systems, CMF/maxillofacial systems, sport medicine systems, joint systems, external fixator systems, orthopedic instruments, and medical power tools.

Quick Links

Contact

Tianan Cyber City, Changwu Middle Road, Changzhou, China
86-18961187889

Keep In Touch

To know more about XC Medico, please subscribe our Youtube channel, or follow us on Linkedin or Facebook. We’ll keep updating our information for you.
© COPYRIGHT 2024 CHANGZHOU XC MEDICO TECHNOLOGY CO., LTD. ALL RIGHTS RESERVED.