RP2HS
XCmedico
1 Pcs(72 Hours Delivery)
Titanium Alloy
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Locking Double Y-Plate | RP2HS623SY3 | 6 holes, 1.0mm, 23mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Locking Double Y-Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Locking Double Y-Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Locking Double Y-Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Locking Double Y-Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Locking Double Y-Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Locking Double Y-Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Locking Double Y-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Locking Double Y-Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Locking Double Y-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini Locking Double Y-Plate is an advanced implant device specifically designed for the stabilization of complex fractures in the maxillofacial region. This comprehensive guide will cover its key features, advantages, applications, risks, and market outlook, offering valuable insights for medical professionals, including surgeons, students, and researchers in the field of maxillofacial surgery. By exploring these elements in depth, this guide will provide a clearer understanding of how the 2.0 Maxillofacial Mini Locking Double Y-Plate serves as an invaluable tool in the surgical management of facial trauma.
The 2.0 Maxillofacial Mini Locking Double Y-Plate is a fixation plate used primarily for treating fractures in the maxillofacial skeleton, such as those in the mandible, zygomatic, and orbital regions. The "2.0" in its name refers to the screw size, which is compatible with screws having a diameter of 2.0 millimeters, ideal for smaller bone structures.
The "double Y" design features two opposing branches shaped like the letter "Y," providing optimal support for fractures that require enhanced stability. This design ensures that the implant can be used in various anatomical regions, particularly those involving complex fracture patterns. The plate is fitted with locking screws that securely attach the plate to the bone, preventing screw loosening and offering long-term stability for the healing process.
The plate features a unique "double Y" shape, which conforms to the contours of the facial bones, ensuring a precise fit for fractures of the mandible, zygoma, or orbital area.
One of the primary features of this plate is its locking screw system. The screws engage with the plate, providing a secure and stable fixation that resists loosening over time, even under the stresses of daily activity.
The plate is equipped with pre-drilled holes for screws, optimized for accurate placement. This design reduces surgical time and minimizes the chance of error during the procedure.
The plate is made from biocompatible materials such as titanium or stainless steel, which are highly resistant to corrosion and minimize the risk of adverse reactions in the body.
With its miniature size, the plate is well-suited for delicate facial bones, such as the zygomatic arch and orbital rim, allowing for minimal incisions and less disruption of surrounding tissues.
The double Y design allows for fixation in multiple orientations, offering versatility when dealing with complex, multi-fragmented fractures or bone reconstruction cases.
The locking mechanism provides excellent stability, ensuring the plate remains firmly in place. This is particularly important in areas of high mechanical stress where non-locking plates may fail to maintain proper alignment.
The plate's compact and anatomically contoured design allows surgeons to perform procedures with minimal incisions, reducing trauma to the soft tissue and accelerating recovery.
Because the plate maintains secure fixation throughout the healing process, there is a lower risk of malunion or nonunion, which can lead to long-term functional or aesthetic issues.
The plate's ability to conform to the natural anatomy of the face means that patients are more likely to achieve an aesthetically pleasing result with minimal scarring, which is especially critical in facial surgeries.
The 2.0 Maxillofacial Mini Locking Double Y-Plate is highly versatile and can be used for a variety of fracture types, from simple fractures to complex, multi-fragmented fractures. Its design ensures it can be adapted to various clinical situations.
Because of its locking mechanism and precise fit, there is less movement at the fracture site, reducing the risk of infection associated with implant instability.
The plate is particularly effective in stabilizing fractures of the mandible, especially in cases of comminuted fractures or fractures involving multiple fragments. Its locking mechanism provides robust fixation even in cases of poor bone quality.
The unique Y-shaped design allows the plate to provide excellent stabilization for fractures of the zygomatic arch, a commonly fractured area in facial trauma.
Orbital fractures often require delicate, precise fixation to avoid damage to the eye structures. The 2.0 Maxillofacial Mini Locking Double Y-Plate can be used effectively in orbital rim fractures, helping restore both function and appearance.
In cases where extensive facial reconstruction is needed after trauma or congenital deformities, the plate provides strong support while allowing for detailed restoration of facial structure.
The locking feature is particularly beneficial in treating comminuted fractures where several bone fragments need to be aligned and stabilized for proper healing. The plate offers a secure environment for bone healing and reduces the need for additional procedures.
As with any implant surgery, there is always a risk of infection at the surgical site, especially if sterile procedures are not followed meticulously during surgery.
The proximity of facial nerves to the surgical site can increase the risk of nerve injury, potentially leading to complications such as facial weakness, numbness, or paralysis.
Although the locking mechanism offers excellent stability, improper placement or excessive stress on the fractured bone during recovery may cause the plate to shift, which could necessitate further surgical intervention.
Some patients may experience allergic reactions to the metallic materials used in the plate, such as titanium or stainless steel, although such occurrences are rare.
In certain cases, factors such as poor blood supply, infection, or excessive mechanical stress may delay bone healing, which could result in nonunion or malunion.
While the plate's design promotes minimal scarring, improper placement or complications during surgery may result in visible deformities or asymmetry, which could require revision surgeries.
As the global population continues to grow and traffic accidents, sports injuries, and violence remain prevalent, the demand for advanced fixation devices in the maxillofacial region is likely to increase.
Ongoing research and development in materials science, implant design, and surgical techniques are expected to enhance the performance and versatility of locking plates, improving their outcomes in facial trauma surgery.
As the global population ages, the incidence of fractures related to osteoporosis and other bone-degenerative conditions will likely drive demand for effective fracture stabilization devices.
Surgeons and patients are increasingly favoring minimally invasive procedures that reduce recovery times and improve overall patient outcomes. The compact and anatomically designed 2.0 Maxillofacial Mini Locking Double Y-Plate is well-suited to these trends.
As healthcare access improves in emerging markets, the global market for advanced maxillofacial implants is expected to grow, including the 2.0 Maxillofacial Mini Locking Double Y-Plate.
The 2.0 Maxillofacial Mini Locking Double Y-Plate represents a significant advancement in the field of maxillofacial surgery, offering exceptional stability, versatility, and aesthetic outcomes in the treatment of complex fractures. With its innovative design, locking screw mechanism, and biocompatible materials, it provides a reliable solution for a wide range of fracture types, from mandibular to orbital fractures. While there are some inherent risks, the benefits of using this plate in terms of improved healing, reduced complications, and faster recovery make it a valuable tool in maxillofacial trauma management. As the market for maxillofacial implants continues to expand, the 2.0 Maxillofacial Mini Locking Double Y-Plate is likely to become an even more essential component of surgical practice.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Name | Picture | Item No. | Specification |
2.0 Maxillofacial Mini Locking Double Y-Plate | RP2HS623SY3 | 6 holes, 1.0mm, 23mm |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For 2.0 Maxillofacial Mini Locking Double Y-Plate Product Catalog.
2. Choose Your Interested 2.0 Maxillofacial Mini Locking Double Y-Plate Product.
3. Ask For A Sample To Test 2.0 Maxillofacial Mini Locking Double Y-Plate.
4.Make An Order Of XC Medico's 2.0 Maxillofacial Mini Locking Double Y-Plate.
5.Become A Dealer Of XC Medico's 2.0 Maxillofacial Mini Locking Double Y-Plate.
1.Better Purchase Prices Of 2.0 Maxillofacial Mini Locking Double Y-Plate.
2.100% The Highest Quality 2.0 Maxillofacial Mini Locking Double Y-Plate.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient 2.0 Maxillofacial Mini Locking Double Y-Plate.
6. Quick And Easy Assessment Of XC Medico's 2.0 Maxillofacial Mini Locking Double Y-Plate.
7. A Globally Recognized Brand - XC Medico.
8. Fast Access Time To XC Medico Sales Team.
9. Additional Quality Test By XC Medico Team.
10. Track Your XC Medico Order From Start To Finish.
The 2.0 Maxillofacial Mini Locking Double Y-Plate is an advanced implant device specifically designed for the stabilization of complex fractures in the maxillofacial region. This comprehensive guide will cover its key features, advantages, applications, risks, and market outlook, offering valuable insights for medical professionals, including surgeons, students, and researchers in the field of maxillofacial surgery. By exploring these elements in depth, this guide will provide a clearer understanding of how the 2.0 Maxillofacial Mini Locking Double Y-Plate serves as an invaluable tool in the surgical management of facial trauma.
The 2.0 Maxillofacial Mini Locking Double Y-Plate is a fixation plate used primarily for treating fractures in the maxillofacial skeleton, such as those in the mandible, zygomatic, and orbital regions. The "2.0" in its name refers to the screw size, which is compatible with screws having a diameter of 2.0 millimeters, ideal for smaller bone structures.
The "double Y" design features two opposing branches shaped like the letter "Y," providing optimal support for fractures that require enhanced stability. This design ensures that the implant can be used in various anatomical regions, particularly those involving complex fracture patterns. The plate is fitted with locking screws that securely attach the plate to the bone, preventing screw loosening and offering long-term stability for the healing process.
The plate features a unique "double Y" shape, which conforms to the contours of the facial bones, ensuring a precise fit for fractures of the mandible, zygoma, or orbital area.
One of the primary features of this plate is its locking screw system. The screws engage with the plate, providing a secure and stable fixation that resists loosening over time, even under the stresses of daily activity.
The plate is equipped with pre-drilled holes for screws, optimized for accurate placement. This design reduces surgical time and minimizes the chance of error during the procedure.
The plate is made from biocompatible materials such as titanium or stainless steel, which are highly resistant to corrosion and minimize the risk of adverse reactions in the body.
With its miniature size, the plate is well-suited for delicate facial bones, such as the zygomatic arch and orbital rim, allowing for minimal incisions and less disruption of surrounding tissues.
The double Y design allows for fixation in multiple orientations, offering versatility when dealing with complex, multi-fragmented fractures or bone reconstruction cases.
The locking mechanism provides excellent stability, ensuring the plate remains firmly in place. This is particularly important in areas of high mechanical stress where non-locking plates may fail to maintain proper alignment.
The plate's compact and anatomically contoured design allows surgeons to perform procedures with minimal incisions, reducing trauma to the soft tissue and accelerating recovery.
Because the plate maintains secure fixation throughout the healing process, there is a lower risk of malunion or nonunion, which can lead to long-term functional or aesthetic issues.
The plate's ability to conform to the natural anatomy of the face means that patients are more likely to achieve an aesthetically pleasing result with minimal scarring, which is especially critical in facial surgeries.
The 2.0 Maxillofacial Mini Locking Double Y-Plate is highly versatile and can be used for a variety of fracture types, from simple fractures to complex, multi-fragmented fractures. Its design ensures it can be adapted to various clinical situations.
Because of its locking mechanism and precise fit, there is less movement at the fracture site, reducing the risk of infection associated with implant instability.
The plate is particularly effective in stabilizing fractures of the mandible, especially in cases of comminuted fractures or fractures involving multiple fragments. Its locking mechanism provides robust fixation even in cases of poor bone quality.
The unique Y-shaped design allows the plate to provide excellent stabilization for fractures of the zygomatic arch, a commonly fractured area in facial trauma.
Orbital fractures often require delicate, precise fixation to avoid damage to the eye structures. The 2.0 Maxillofacial Mini Locking Double Y-Plate can be used effectively in orbital rim fractures, helping restore both function and appearance.
In cases where extensive facial reconstruction is needed after trauma or congenital deformities, the plate provides strong support while allowing for detailed restoration of facial structure.
The locking feature is particularly beneficial in treating comminuted fractures where several bone fragments need to be aligned and stabilized for proper healing. The plate offers a secure environment for bone healing and reduces the need for additional procedures.
As with any implant surgery, there is always a risk of infection at the surgical site, especially if sterile procedures are not followed meticulously during surgery.
The proximity of facial nerves to the surgical site can increase the risk of nerve injury, potentially leading to complications such as facial weakness, numbness, or paralysis.
Although the locking mechanism offers excellent stability, improper placement or excessive stress on the fractured bone during recovery may cause the plate to shift, which could necessitate further surgical intervention.
Some patients may experience allergic reactions to the metallic materials used in the plate, such as titanium or stainless steel, although such occurrences are rare.
In certain cases, factors such as poor blood supply, infection, or excessive mechanical stress may delay bone healing, which could result in nonunion or malunion.
While the plate's design promotes minimal scarring, improper placement or complications during surgery may result in visible deformities or asymmetry, which could require revision surgeries.
As the global population continues to grow and traffic accidents, sports injuries, and violence remain prevalent, the demand for advanced fixation devices in the maxillofacial region is likely to increase.
Ongoing research and development in materials science, implant design, and surgical techniques are expected to enhance the performance and versatility of locking plates, improving their outcomes in facial trauma surgery.
As the global population ages, the incidence of fractures related to osteoporosis and other bone-degenerative conditions will likely drive demand for effective fracture stabilization devices.
Surgeons and patients are increasingly favoring minimally invasive procedures that reduce recovery times and improve overall patient outcomes. The compact and anatomically designed 2.0 Maxillofacial Mini Locking Double Y-Plate is well-suited to these trends.
As healthcare access improves in emerging markets, the global market for advanced maxillofacial implants is expected to grow, including the 2.0 Maxillofacial Mini Locking Double Y-Plate.
The 2.0 Maxillofacial Mini Locking Double Y-Plate represents a significant advancement in the field of maxillofacial surgery, offering exceptional stability, versatility, and aesthetic outcomes in the treatment of complex fractures. With its innovative design, locking screw mechanism, and biocompatible materials, it provides a reliable solution for a wide range of fracture types, from mandibular to orbital fractures. While there are some inherent risks, the benefits of using this plate in terms of improved healing, reduced complications, and faster recovery make it a valuable tool in maxillofacial trauma management. As the market for maxillofacial implants continues to expand, the 2.0 Maxillofacial Mini Locking Double Y-Plate is likely to become an even more essential component of surgical practice.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.