RG2GMSD
XCmedico
1 Pcs(72 Hours Delivery)
Femoral
Titanium Alloy Or Stainless Steel
CE/ISO:9001/ISO13485.Etc
Custom-Made 15 Days Delivery(Excluding Shipping Time)
FedEx. DHL.TNT.EMS.Etc
Availability: | |
---|---|
Quantity: | |
Product | Picture | REFTitanium Alloy | Specification |
Gamma Intramedullary Nailmatch 4.5mm/6.0mm Locking Screw Full-Threaded | RG2GMSD09180 | Ф9×180 | |
RG2GMSD09200 | Ф9×200 | ||
RG2GMSD09220 | Ф9×220 | ||
RG2GMSD09240 | Ф9×240 | ||
RG2GMSD09260 | Ф9×260 | ||
RG2GMSD09280 | Ф9×280 | ||
RG2GMSD10180 | Ф10×180 | ||
RG2GMSD10200 | Ф10×200 | ||
RG2GMSD10220 | Ф10×220 | ||
RG2GMSD10240 | Ф10×240 | ||
RG2GMSD10260 | Ф10×260 | ||
RG2GMSD10280 | Ф10×280 | ||
RG2GMSD11180 | Ф11×180 | ||
RG2GMSD11200 | Ф11×200 | ||
RG2GMSD11220 | Ф11×220 | ||
RG2GMSD11240 | Ф11×240 | ||
RG2GMSD11260 | Ф11×260 | ||
RG2GMSD11280 | Ф11×280 |
End CapInner screw thread design on the end of the nail makes easier for nail extractingScrewEach nail with 4 free locking screws and full-thread locking screws For true rotational stability. Angle5"lateral offset for minimally invasive trochanteric entry.Cannulated DesignCannulated, round geometry for ease of insertion using reamed or undreamed technique.Distal ellipse locking holefor dynamic compression.Tail designFlexible distal nail end minimizes stress concentration. |
Solid raw materials are used to drill holes, and alloy (TC4) or medical stainless steel (317L) materials are selected to ensure the strength and hardness of the intramedullary nail. |
Suitable for femoral neck, proximal, middle and distal femoral fractures. |
Multiple specifications: To accommodate individual patient anatomy. |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Gamma Intramedullary Nail Product Catalog.
2. Choose Your Interested Gamma Intramedullary Nail Product.
3. Ask For A Sample To Test Gamma Intramedullary Nail Quality.
4.Make An Order Of Xc Medico's Gamma Intramedullary Nail.
5.Become A Dealer Of Xc Medico's Gamma Intramedullary Nail.
1.Better Purchase Prices Of Gamma Intramedullary Nail.
2.100% The Highest Quality Gamma Intramedullary Nail.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Gamma Intramedullary Nail.
6. Quick And Easy Assessment Of Xc Medico's Gamma Intramedullary Nail.
7. A Globally Recognized Brand - Xc Medico.
8. Fast Access Time To Xc Medico Sales Team.
9. Additional Quality Test By Xc Medico Team.
10. Track Your Xc Medico Order From Start To Finish.
This type of nail is particularly useful in treating fractures around the hip and proximal femur (the upper part of your thigh bone). The Gamma Nail is a long, sturdy rod inserted into the center (medullary canal) of your femur, holding the broken bone in place from within. Think of it like inserting a steel rod into a hollow tube to stabilize it. The nail is locked in place with screws that go through the bone, holding everything tightly together, like screws anchoring a shelf.
The Gamma Nail is designed to follow the natural contour of the femur, making it an anatomically accurate solution. It’s not just a straight rod; it has curves and angles that mimic your body’s natural shape. This ensures that it fits comfortably and securely, working with your body rather than against it.
What keeps the nail in place? The answer lies in the locking screws that are placed at both ends of the nail—near the hip and down toward the knee. These screws act like anchors, preventing the nail from shifting or moving, even under pressure.
The beauty of the Gamma Nail is that it’s inserted using small incisions. This means that the surrounding muscles and tissues suffer less trauma, unlike with traditional open surgeries that require larger cuts. Imagine having a problem fixed from the inside without messing too much with the outside—it’s much like using a keyhole to fix the inner workings of a lock.
Made from titanium or stainless steel, the Gamma Nail is incredibly strong. These materials are lightweight yet durable enough to withstand the forces placed on them while you move around. It’s like having an indestructible internal brace, one that you won’t even notice is there.
The Gamma Nail has a unique feature: its ability to provide angular stability, meaning it can help correct misaligned fractures. Think of it as a ruler that helps guide the bone fragments back into the perfect position so that they can heal in the correct alignment.
One of the biggest advantages of the Gamma Nail is that it allows patients to start moving much sooner than other treatment options.
Thanks to the minimally invasive nature of the surgery, there’s less muscle and tissue damage compared to traditional open surgery. Fewer cuts mean less pain.
For patients with osteoporosis or brittle bones, the Gamma Nail is a lifesaver. Its design is tailored to support weaker bones that might not handle other fixation methods as well.
The combination of early mobilization, reduced pain, and stable fixation means a faster overall recovery. Patients can return to their daily routines more quickly than with older treatment methods.
Compared to older methods like plate fixation, the Gamma Nail significantly reduces the risk of complications like malunion (bones healing in the wrong position) or hardware failure (plates or screws breaking).
The patient is given anesthesia to ensure comfort during the surgery.
A small incision is made near the fracture site.
The broken bone fragments are realigned and reduced to their proper position.
The gamma intramedullary nail is inserted into the medullary canal of the femur.
Locking screws are inserted to secure the nail and the fractured bone fragments.
The incision is closed with sutures or surgical glue.
Maintaining a clean wound and following post-surgical care instructions is crucial to prevent infection.
In rare cases, the bone may not heal properly, requiring additional surgery.
The nail may break or loosen, necessitating further treatment.
There is a risk of nerve injury during the surgery.
The affected leg may be immobilized in a cast or brace for some time.
Rehabilitation exercises are essential to regain strength, range of motion, and stability.
Weight-bearing on the affected leg may be gradually increased as the bone heals.
Regular follow-up appointments with your surgeon are important to monitor healing progress and address any concerns.
The timeline for returning to full activity varies depending on individual factors, such as the severity of the fracture, the patient's overall health, and adherence to the rehabilitation plan. However, many patients can gradually resume normal activities within six months of surgery.
According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including gamma intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers.
Gamma intramedullary nails offer a safe and effective solution for treating femoral fractures. By understanding the features, benefits, and potential risks associated with this procedure, patients and healthcare providers can make informed decisions about their treatment options.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Product | Picture | REFTitanium Alloy | Specification |
Gamma Intramedullary Nailmatch 4.5mm/6.0mm Locking Screw Full-Threaded | RG2GMSD09180 | Ф9×180 | |
RG2GMSD09200 | Ф9×200 | ||
RG2GMSD09220 | Ф9×220 | ||
RG2GMSD09240 | Ф9×240 | ||
RG2GMSD09260 | Ф9×260 | ||
RG2GMSD09280 | Ф9×280 | ||
RG2GMSD10180 | Ф10×180 | ||
RG2GMSD10200 | Ф10×200 | ||
RG2GMSD10220 | Ф10×220 | ||
RG2GMSD10240 | Ф10×240 | ||
RG2GMSD10260 | Ф10×260 | ||
RG2GMSD10280 | Ф10×280 | ||
RG2GMSD11180 | Ф11×180 | ||
RG2GMSD11200 | Ф11×200 | ||
RG2GMSD11220 | Ф11×220 | ||
RG2GMSD11240 | Ф11×240 | ||
RG2GMSD11260 | Ф11×260 | ||
RG2GMSD11280 | Ф11×280 |
End CapInner screw thread design on the end of the nail makes easier for nail extractingScrewEach nail with 4 free locking screws and full-thread locking screws For true rotational stability. Angle5"lateral offset for minimally invasive trochanteric entry.Cannulated DesignCannulated, round geometry for ease of insertion using reamed or undreamed technique.Distal ellipse locking holefor dynamic compression.Tail designFlexible distal nail end minimizes stress concentration. |
Solid raw materials are used to drill holes, and alloy (TC4) or medical stainless steel (317L) materials are selected to ensure the strength and hardness of the intramedullary nail. |
Suitable for femoral neck, proximal, middle and distal femoral fractures. |
Multiple specifications: To accommodate individual patient anatomy. |
CNC Preliminary Processing The computer numerical control technology is used to precisely process orthopedic products. This process has the characteristics of high precision, high efficiency, and repeatability. It can quickly produce customized medical devices that conform to the human anatomical structure and provide patients with personalized treatment plans. | Product Polishing The purpose of orthopedic products polishing is to improve the contact between the implant and human tissue, reduce stress concentration, and improve the long-term stability of the implant. | Quality Inspection The mechanical properties test of orthopedic products is designed to simulate the stress conditions of human bones, evaluate the load-bearing capacity and durability of implants in the human body, and ensure their safety and reliability. |
Product Package Orthopedic products are packaged in a sterile room to ensure that the product is encapsulated in a clean, sterile environment to prevent microbial contamination and ensure surgical safety. | Product Warehouse The storage of orthopedic products requires strict in-and-out management and quality control to ensure product traceability and prevent expiration or wrong shipment. | Sample Room The sample room is used to store, display and manage various orthopedic products samples for product technology exchanges and training. |
1. Ask Xc Medico Team For Gamma Intramedullary Nail Product Catalog.
2. Choose Your Interested Gamma Intramedullary Nail Product.
3. Ask For A Sample To Test Gamma Intramedullary Nail Quality.
4.Make An Order Of Xc Medico's Gamma Intramedullary Nail.
5.Become A Dealer Of Xc Medico's Gamma Intramedullary Nail.
1.Better Purchase Prices Of Gamma Intramedullary Nail.
2.100% The Highest Quality Gamma Intramedullary Nail.
3. Less Ordering Efforts.
4. Price Stability For The Period Of Agreement.
5. Sufficient Gamma Intramedullary Nail.
6. Quick And Easy Assessment Of Xc Medico's Gamma Intramedullary Nail.
7. A Globally Recognized Brand - Xc Medico.
8. Fast Access Time To Xc Medico Sales Team.
9. Additional Quality Test By Xc Medico Team.
10. Track Your Xc Medico Order From Start To Finish.
This type of nail is particularly useful in treating fractures around the hip and proximal femur (the upper part of your thigh bone). The Gamma Nail is a long, sturdy rod inserted into the center (medullary canal) of your femur, holding the broken bone in place from within. Think of it like inserting a steel rod into a hollow tube to stabilize it. The nail is locked in place with screws that go through the bone, holding everything tightly together, like screws anchoring a shelf.
The Gamma Nail is designed to follow the natural contour of the femur, making it an anatomically accurate solution. It’s not just a straight rod; it has curves and angles that mimic your body’s natural shape. This ensures that it fits comfortably and securely, working with your body rather than against it.
What keeps the nail in place? The answer lies in the locking screws that are placed at both ends of the nail—near the hip and down toward the knee. These screws act like anchors, preventing the nail from shifting or moving, even under pressure.
The beauty of the Gamma Nail is that it’s inserted using small incisions. This means that the surrounding muscles and tissues suffer less trauma, unlike with traditional open surgeries that require larger cuts. Imagine having a problem fixed from the inside without messing too much with the outside—it’s much like using a keyhole to fix the inner workings of a lock.
Made from titanium or stainless steel, the Gamma Nail is incredibly strong. These materials are lightweight yet durable enough to withstand the forces placed on them while you move around. It’s like having an indestructible internal brace, one that you won’t even notice is there.
The Gamma Nail has a unique feature: its ability to provide angular stability, meaning it can help correct misaligned fractures. Think of it as a ruler that helps guide the bone fragments back into the perfect position so that they can heal in the correct alignment.
One of the biggest advantages of the Gamma Nail is that it allows patients to start moving much sooner than other treatment options.
Thanks to the minimally invasive nature of the surgery, there’s less muscle and tissue damage compared to traditional open surgery. Fewer cuts mean less pain.
For patients with osteoporosis or brittle bones, the Gamma Nail is a lifesaver. Its design is tailored to support weaker bones that might not handle other fixation methods as well.
The combination of early mobilization, reduced pain, and stable fixation means a faster overall recovery. Patients can return to their daily routines more quickly than with older treatment methods.
Compared to older methods like plate fixation, the Gamma Nail significantly reduces the risk of complications like malunion (bones healing in the wrong position) or hardware failure (plates or screws breaking).
The patient is given anesthesia to ensure comfort during the surgery.
A small incision is made near the fracture site.
The broken bone fragments are realigned and reduced to their proper position.
The gamma intramedullary nail is inserted into the medullary canal of the femur.
Locking screws are inserted to secure the nail and the fractured bone fragments.
The incision is closed with sutures or surgical glue.
Maintaining a clean wound and following post-surgical care instructions is crucial to prevent infection.
In rare cases, the bone may not heal properly, requiring additional surgery.
The nail may break or loosen, necessitating further treatment.
There is a risk of nerve injury during the surgery.
The affected leg may be immobilized in a cast or brace for some time.
Rehabilitation exercises are essential to regain strength, range of motion, and stability.
Weight-bearing on the affected leg may be gradually increased as the bone heals.
Regular follow-up appointments with your surgeon are important to monitor healing progress and address any concerns.
The timeline for returning to full activity varies depending on individual factors, such as the severity of the fracture, the patient's overall health, and adherence to the rehabilitation plan. However, many patients can gradually resume normal activities within six months of surgery.
According to Apol's research, the global intramedullary nail market sales in 2023 will be approximately US$470 million, and it is expected to grow at a CAGR (compound annual growth rate) of more than 3.82% during the forecast period of 2024-2030. This shows that the intramedullary nail market, including gamma intramedullary nails, will continue to expand globally, providing a broad market space for manufacturers and suppliers.
Gamma intramedullary nails offer a safe and effective solution for treating femoral fractures. By understanding the features, benefits, and potential risks associated with this procedure, patients and healthcare providers can make informed decisions about their treatment options.
Warm reminder: This article is for reference only and cannot replace the doctor's professional advice. If you have any questions, please consult your attending physician.
Contact